• Title/Summary/Keyword: Retention force

Search Result 169, Processing Time 0.027 seconds

Differences in retention of the reduction direction depending on dimensions and design CAD/CAM zirconia abutment for implant (Implant에 사용되는 CAD/CAM 전용 zirconia abutment의 표면적과 디자인에 따른 유지력 차이)

  • Nam, Taeg-Mo;Kim, Han-Gon;Kim, Byung-Sik;Lim, Si-Duk
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.317-325
    • /
    • 2010
  • Purpose: The aim of this study is to make some basic materials to find retention force difference based on the total height of CAD/CAM zirconia abutment used for implant, retention force difference based on how to regulate the height of the abutment, retention force difference based on the size and retention force difference based on the design group. Methods: The retention force was measured by being pulled at the speed of 1mm/min after being combined with zirconia block and abutment using Temp-BOND of Kerr. The experiment was done at the research lab of OSTEM in Busan by useing UNIVERSAL TESTING MACHINE on March 3rd, 2010. Results: After analysing the total height and the retention force, p-value had minor difference by 0.01 statistically. Namely, 3mm, 4mm, 5mm had the retention force difference and we could see retention force difference on 3mm and 5mm at the post test. After analyzing how to regulate the height and retention force, p-value had minor difference by 0.000 statistically. Namely, 1mm and 2mm had the retention difference and we could see that 1mm and 2mm with the total height had retention difference. After analyzing the retention force based on the size, p-value had minor retention force difference by 0.000 statistically. Namely, 7 different size had retention force difference and we could see the size 21.9mm, 32.9mm, 32.9mm, 38.4mm, 48.9mm and 54.9mm had retention force difference. Conclusion: Namely 9 different design group had retention difference and we could see that 9 design group with 5.6.7.8 design group and 9 design group with 1.2.3.4. design group had retention force.

Comparison of retention forces with various fabrication methods and materials in double crowns

  • Guven, Melahat Celik;Tuna, Meral;Bozdag, Ergun;Ozturk, Gizem Nur;Bayraktar, Gulsen
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.308-314
    • /
    • 2017
  • PURPOSE. The purpose of this study was to analyze the retention force changes and wear behaviours of double-crown systems over long-term use. MATERIALS AND METHODS. Ten groups, each consisting of six samples, were evaluated. Specifically, casting gold alloy primary crown - casting gold alloy secondary crown (AA), laser sintering primary crown - laser sintering secondary crown (LL), casting Cr alloy primary crown - casting Cr alloy secondary crown, (CC) zirconia primary crown - electroformed secondary crown (ZA), and CAD/CAM titanium alloy primary crown - CAD/CAM titanium alloy secondary crown (TT) groups were evaluated at cone angles of $4^{\circ}$ and $6^{\circ}$. The samples were subjected to 5,000 insertion-separation cycles in artificial saliva, and the retention forces were measured every 500 cycles. The wear levels were analyzed via SEM at the beginning and end of the 5,000 cycles. RESULTS. In all samples, the retention forces increased when the conus angle decreased. The highest initial and final retention force values were found in the $LL-4^{\circ}$ group (32.89 N-32.65 N), and the lowest retention force values were found in the $ZA6^{\circ}$ group (5.41 N-6.27 N). The ZA groups' samples showed the least change in the retention force, and no wear was observed. In the other groups, wear was observed mostly in the primary crowns. CONCLUSION. More predictable, clinically relevant, and less excursive retention forces can be observed in the ZA groups. The retention force values of the LL groups were statically similar to those of the other groups, except the ZA groups.

Decision Analysis with Value Focused Thinking as a Methodology to Access Air Force Officer Retention Alternatives

  • Moon Sang-ho
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2004.11a
    • /
    • pp.105-110
    • /
    • 2004
  • Decision Analysis(DA) using Value Focused Thinking(VFT) can be an excellent process to deal with hard decisions. The intent of this research is to provide better understanding of the United States Air Force(USAF) officer retention problem. This thesis effort involves building a VFT model to find out more effective alternatives in retaining pilots and non pilots. This model, in conjunction with the results of the post analysis, shows an example of the application of a VFT approach to the USAF officer retention problem.

  • PDF

EXPERIMENTAL STUDY ON THE RETENTION FORCE OF INLAY CAVITY (와동의 깊이 및 넓이의 변화가 Inlay 유지력에 미치는 영향에 관한 실험적 연구)

  • Hahn, Taik-Seon;Choi, Zai-Kyung
    • The Journal of the Korean dental association
    • /
    • v.9 no.7
    • /
    • pp.431-437
    • /
    • 1971
  • The authors performed an experimental study on the retention force in cavities with various depth and width. We used the simple model cavities which were cylindrically formed to eliminate the unexpected influence during experiment, and obtained following results. 1. The retention force in the cavities with parallel wall was vigorous even in the small cavity and increased considerably followed by extending the cavity size. 2. The ratention force resulted more vigorously by that the depth became deeper than that the distance between the lateral walls became longer. 3. Compared with the retention force in the cavities which had the same frictional lateral surface, it was more vigorous in the deeper cavity than in the cavity which was longer distance between the lateral surfaces.

  • PDF

Evaluation of Complaint Press-Fit pin for Telecommunications (통신 교환기 고밀도 접속용 탄성 압입 핀의 특성 평가)

  • Shin, Dong-Pill;Jeong, Myung-Yung;Hong, Sung-In
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.481-485
    • /
    • 2000
  • A new type of compliant press-fit pin has been developed and evaluated for use packaging of electronic telecommunications equipments. Main requirements for design are defined the upper limit of pin insertion force and the lower limit of pin retention force. Upper limit of pin insertion force is set to protect the copper plate of the inner PTH wall. Lower limit of pin retention force is set to satisfy a wire-wrapping specification. Results are represented by insertion force and retention force variations according to the front angle, rear angle and material, etc.

  • PDF

A Study on the Interconnection Mechanism of Compliant Press-Fit Pin(II) (Compliant Press-Fit Pin에 의한 접속기구에 관한 연구(II))

  • 전병희;안기순
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.89-99
    • /
    • 1993
  • In this research, important mechanical characteristics of Compliant Press-Fit Pin and PHT are studied through the analysis of deformation mechanisms of Press-Fit Pin and by elastic-plastic finite element method. The direct data for the optimal design of pin was obtained without interfere with the criterion on insertion force and retention force. Also, the insertion force and retention force of new type pin were measured by precision type tensile testing machine and it revealed good agreement with analytical results. In conclusion, it is believed that above results will contribute satisfactorily to the practical design of Press-Fit Pin.

  • PDF

MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY (Co-Cr-Ti 합금으로 제작한 conical telescope 외관의 변연적합도와 유지력에 관한 연구)

  • Jung, Hi-Chan;Jeong, Chang-Mo;Jeon, Young-Chan;Lim, Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.214-225
    • /
    • 2000
  • The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials(plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment(Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by ${\times}100$ compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials(P>0.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(P>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.

  • PDF

A HISTOLOGIC STUDY OF PULPAL REACTION AFTER EXPERIMENTAL TOOTH MOVEMENT IN RATS (백서구치의 실험적 치아이동후 치수조직 변화에 관한 조직학적 연구)

  • Jin, Keun Ho;Hong, Sung Joon
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.635-656
    • /
    • 1991
  • It was the aim of this investigation to evaluate some histologic aspect of rat pulp tissue after it had been compromised by an experimental orthodontic force. Experimental animals of thirty five Spraque-Dawley rats were employed. The first upper molars had been successively mesial moved (initial load 100 gr.) with a closed coil spring during 21 days. The experimental periods were set on immediate, 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks following retention time. On each experimental period, the rats were killed and prepared for the light microscopy. After prepared with H/E stain and Gomori's one-step trichrome stain, the specimens were analyzed with evaluation criteria which were adopted in this study. The result may be summarized as follows; 1. The main pulp changes due to experimental orthodontic force included vacuolization of odontoblastic layer, circulation disturbance, root resorption, reduced pulp collagenous fiber density and mean cell count of pulp fibroblast in the immediate group. 2. The pulp tissue changes were revealed reversible because the relieved pulp tissues from experimental orthodontic force were recovered rapidly in each evaluation criteria during retention periods. 3. Compared with normal control group, pulp collagenous fiber density were decreased in immediated group (p < 0.01), but increased in each retention groups. These seem to suggest that the pulp tissues were aged after experimental orthodontic force conditions. 4. Compared with normal control group, mean cell counts of pulp fibroblasts were decreased in immediate group (p < 0.05), but increased continuous in each retention groups. These seem to indicate that the pulp tissues were highly regenerative after experimental orthodontic force conditions. 5. Compared with normal control group, root resorptions occurred in all immediate specimens (p < 0.01) and they were healed in each retention periods, but often observed in 4 weeks retention group. These seem to indicate that root resorptions were recovered slowly after experimental orthodontic force conditions.

  • PDF

Fiction Coefficient between Abutment Materials and Clasp Materials and Estimation of Retention Force of Circumferential Clasp (지대치의 재료와 Clasp 재료 사이의 마찰계수와 원형 clasp의 유지력 추정)

  • Lim, Dong-Chun
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.67-75
    • /
    • 1999
  • The purpose of this study is to evaluate the friction coefficients between abutment materials and clasp materials, and to an estimation formula for retention force. The coefficients of friction between three clasp materials and four abutment materials were measured under various conditions, polished and sandblasted and wet and dry. The measurement was repeated for each combination up to a total measurement of 1200 times. Estimation formula for retention force is measured as sum of two terms, which the one time is proportional to the product of friction coefficient ${\mu}$ and undercut u and the other term is proportional to u-squared. Two proportional coefficient were obtained by least square method. The results are as follows: 1. Friction coefficients were ranged from 0.08 to 0.53 under various conditions. 2. Friction coefficients of non-metal abutment materials are greater in wet conditions than dry conditions. 3. Friction coefficients of sandblasted clasp against abutment are greater than that of polished clasp. 4. Clasp retention force can be estimated with the model as F=$F_d(3.0{\mu}u+1.5u^2/h)$ with minor error.

  • PDF

A research about micro size polymer bead injecting process based on electrostatic force (정전기력 기반의 마이크로 사이즈 폴리머 비드 주입 공정 연구)

  • Yang, Bong-Su;Yang, Sung-Wook;Ko, Jung-Bum;Choi, Kyung-Hyun;Doh, Yang-Hoi
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.43-50
    • /
    • 2016
  • This research proposal is based on a novel non-contact technique of micro-sized bead injection process for fabrication of electronic paper display. This non-contact injection process is based on the principle of electrostatic force and uses micro-sized metal-coated beads dispersed in a solution. The dispersion retention times of three different solutions with viscosities of 10 cps, 100 cps, and 1000 cps were measured by optical equipment showing the retention times of 5 mins, 10 mins, and 30 mins respectively. The dispersion retention rate dropped as the time passed. The dispersion retention characteristic of 1000 cps solution was more stable as compared to those of 10 cps and 100 cps meaning that higher viscosity has better retention properties. The experimental results of bead injection at different viscosity levels of the solution were also measured and a stable injection result was achieved by using 1000 cps solution. This results show that stable injection is dependent on solution viscosity and dispersion.