A Study on the Mock-up Test of Waterproofing/Root Penetration Resistance Technology for the Application to an Eco-bridge (생태교량 적용을 위한 방수·방근공법의 Mock-up 시험 연구)

  • Seon, Yun-Suk;Choi, Su-Young;Kim, Meong-Ji;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.230-231
    • /
    • 2014
  • This study is concerned with the root penetration resistance competence and constructability of a waterproofing and root penetration resistance layer of an eco-bridge which is applied with various types of seeding. For the review of root penetration resistance competence, the competence was tested using herbs, woody plants, and tall trees. As a result, there was no tear of or damage to the waterproofing and root penetration resistance layer as well as the sweeping-down phenomenon of a waterproofing and root penetration resistance layer by soil. Also, the effect of the root growth of herbs, woody plants, and tall trees on the root penetration resistance system was confirmed.

  • PDF

A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System (인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구)

  • Lee, Jung-Hoon;Seon, Yun-Suk;Kwak, Kyu Sung;Oh, Sang-Keu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF

A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs (옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구)

  • Oh, Sang-Keun;Kwak, Kyu-Sung;Sun, Yoon-Suk;Kwon, Shi-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.79-84
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we would suggest 5 items of test methods considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, size of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System (옥상녹화 및 인공지반녹화용 구리시트 방근재의 성능평가에 관한 연구)

  • Cho, Il-Kyu;Kwon, Shi-Won;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.5-8
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we examine the practical use of copper sheet considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, sire of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

  • PDF

A Study on the Workability and Application of Cooper Plate based on the Waterproofing and Root Penetration Resistance (옥상녹화 방수 및 방근 기술로서 동판재의 적합성 및 시공성에 관한 연구)

  • Park, Chang-Hwa;Cho, Il-Kyu;Kwon, Shi-Won;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.151-154
    • /
    • 2007
  • To build up the green roofs, it must not adverse effect to durability and structural safety. That is conducted by safety system which consist of waterproofing to form basically, root barrier to protect the waterproofing. The reason why root barrier form is to protect the penetration force of root growth and the root could penetrate concrete surface, move inward so far. It may cause shorten the life span on concrete structure. For this problem, government constantly demand the solution to form the root barrier for waterproofing and concrete structure before the building is service. However, the technical action is not fully prepared. Therefore, in this study, we would like to suggest the workability and suitability of the copper plate to solve not only the side of waterproofing but also root barrier for green roof system and exhibit the mechanism for root penetration resistance and corrosion resistance.

  • PDF

Test for Root Penetration Resistance for Waterproofing Layer proper to assure Structural Safety on the Concrete (인공녹화 기반 콘크리트 구조체의 안전성 확보를 위한 옥상녹화 방수층의 내근성 평가)

  • Kwon, Shi-Won;Sun, Yun-Suk;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.873-876
    • /
    • 2006
  • At the green roof on the concrete structure, root penetration can be the most problem to water leakage. Root occur cracks due to penetrate to concrete which have porous organization by itself. Crack on the concrete structure would be constantly shrinks and expands, it occur to water leakage and decrease durability of concrete structure. Therefore, in this paper, the result of the root penetration test for waterproofing which protect concrete structure from the water leakage or other environment conditions would be apply to understand the reason of root penetration.

  • PDF

Direction to Develop Domestic Technology for Waterproofing and Root Penetration Resistance in Comparative Study of Overseas Technology on Green Roof System (국내외 옥상녹화 기술현황분석을 통한 국내 방수.방근기술의 개선방향연구)

  • Kwon, Shi-Won;Bae, Kee-Sun;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.13-17
    • /
    • 2007
  • The green roof industry have been developed with Europe, North America, Japan. At the same time, being recognized the important of green roofs in domestic industry and we just start to develop the relative technology as analyzing the future direction of advanced technology. Recently, local self-government including Seoul support the system for green roof which provide 50% of working expenses form of Matching Fund by Seed Money. As years go by, the number of build up the green roof has gradually increased to be proved. At this result caused by management of system in government, unstructured construction system, low development of support technology. In this study as analyzing the present of technical development, supporting by law and system for the advanced waterproofing and root penetration resistance technology, we suggest the development direction of it to be compared with application advanced technology and we could strengthen the international competitiveness to be industrialized the green roof considering system, technology, human infrastructure.

  • PDF

Development of Self-propelled Explosive Subsoiler (1) - Present Status of Soil Compaction and Subsoil Management in Orchard - (자주식 심토환경 개선기 개발(1) - 과수원의 토양 다짐 특성 및 심토 관리 실태 -)

  • Lee, Dong-Hoon;Park, Woo-Pung;Lee, Kyou-Seung
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.397-403
    • /
    • 2009
  • This study was carried out to investigate the present status of subsoil compaction, and subsoil compaction management in orchard as a basic study for developing a self-propelled explosive subsoiler. Subsoil compaction was evaluated using the soil penetration resistance. Soil cone index was measured using the DIK 5520 type cone penetrometer in several fruit farms such as apple, pear, peach and grapes during growing seasons of these fruit in Jecheon, Gamgok, Choongju, Cheonan and Hwasung areas. Most of the subsoil managing machinery were either explosive type or digging type attached to the tractor or power tiller and turning radius of this machine was more than 3-5 m. Many of the farmers wanted to use the subsoiler which can put lime into soil and rupture soil at the same time. For most of the orchard fields, soil penetration resistance in vehicle traffic area was increased quickly and reached about 1.0 MPa in 5 cm soil depth. As the soil depth increased to 15-20 cm, cone penetration resistance reached about 2.0-2.5 MPa which restricted root growth seriously. Thus it was concluded that one of the main reason for increasing the soil compaction in orchard fields is agricultural vehicle traffic. In the vicinity of fruit trees, compaction is not so serious compared to that of the vehicle traffic area, but as the soil depth increased to 20-25 cm, in most of the orchard fields soil penetration resistance reached about 2.0-2.5 MPa which is the root growth-limiting value. Considering the rooting depth of fruit trees which ranged 30-60 cm for apple, pear and peach, and 20-30 cm for grape, it is necessary to loosen the subosoil and improve the subsoil conditions using subsoiler.

Biological and Structural Mechanisms of Disease Development and Resistance in Chili Pepper Infected with the Root-knot Nematode

  • Moon, Hyo-Sun;Khan, Zakaullah;Kim, Sang-Gyu;Son, Seon-Hye;Kim, Young-Ho
    • The Plant Pathology Journal
    • /
    • v.26 no.2
    • /
    • pp.149-153
    • /
    • 2010
  • Biological and structural mechanisms of the nematode disease development in chili pepper caused by the root-knot nematode, Meloidogyne incognita, were investigated. Out of 39 chili pepper cultivars/lines tested, six were found resistant, while 33 were susceptible to M. incognita, of which a susceptible cultivar Chilseongcho and three resistant cultivar/lines CM334, 02G132 and 03G53 with different resistance degrees were selected for microscopic studies on the disease development. Gall formation was greatly reduced in the resistant cultivars/lines. Nematode penetration occurred both in the susceptible and resistant chili pepper roots; however, the penetration rates were significantly lowered in the three resistant peppers compared to the susceptible pepper cv. Chilseongcho. In the susceptible pepper, giant cells were extensively formed with no discernible necrosis around the nematode feeding sites. In the highly resistant pepper cultivar CM334, no giant cell was formed, but extensive necrosis formation was observed around the penetrating nematodes. In the other two resistant pepper lines (02G132 and 03G53), both giant cells and prominent necroses were formed, and the necrotic responses appeared to inhibit the further development of giant cells or accelerate their early degeneration. Although the nematode penetration was retarded significantly in the resistant cultivar/lines, all of the above results suggest that the disease resistance of pepper may be related to post-infectional defense mechanisms (nematode growth and development) more than pre-infectional ones (penetration and establishment). Variations in structural modifications in the resistant cultivar/lines may reflect their genetic differences related to the nematode resistance.

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.