Empirical Application for the Urban Disaster Risk Assessment : Fire, Facility and Escape Cases in Cheongju City (도시 재해위험도 평가 모형 연구 - 화재, 시설, 피난위험도 중심의 청주시 사례 -)

  • Hwang, Hee-Yun;Baek, Ki-Young;Park, Byung-Ho;Lee, Man-Hyung;Hwang, Jae-Hoon;Ryu, Eul-Leal;Kim, Tae-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.1 no.2 s.2
    • /
    • pp.123-137
    • /
    • 2001
  • Based on basic characteristics of urban disasters and their data availabilities in Korea, this study provides risk assessment models which are derived from Cheongju examples. In specific, the application models are confined to fire, facility and escape risk survey results in the paper. For the assessment criteria, major independent variables for the categories of fire include both the frequency levels and the amount of damage. And the degree of facility risk assessment is heavily hinged on both the weighted values of key facilities and their weighted rank-sizes. In the same context, the degree of escape risk assessment is hinged on both the weighted values and the amount of the classification of land. From the empirical configuration, this paper presents that the potential figure of fire risk is relatively higher in the built-up areas within the existing Central Business District where accommodates a number of dilapidated housing units and community-supportive facilities. In contrast, the potential figure of facility and escape risk is higher in both old residential areas and the newly-built apartment complex. In short, the CBD and its neighboring residential areas record a high potential figure in terms of total risk, juxtaposing fire, facility and escape risk all together.

  • PDF

Policy Direction for Fire Products Life Expectancy Legislation (소방용품 내용연수 제도화 정책방안)

  • Baek, Chang Sun;Park, In-Seon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.111-120
    • /
    • 2016
  • This study is intended to provide legislative direction for fire products life expectancy. Domestic and international laws relating to fire products life expectancy have been reviewed, and the results of a Fire Safety Manager Consciousness (FSMC) survey were analyzed. The FSMC survey has been designed in order to assist with the establishment of appropriate fire safety policy. A questionnaire survey was conducted with 660 fire safety administrators from 17 municipal and provincial districts, with the intention of gaining expertise on the extension of life-span for 32 fire products. The survey also asked for candidates opinions on future policy direction. Based on the survey results and the review of policies within other nations, we have devised a set of policy issues with the intention of extending the life-span of fire-safety items. The survey result revealed that 79.3% of Fire Safety Managers (FSMs) concurred with the establishment of legislation regarding the maintenance and correct care of fire-safety products. Overall, over 30% of FSMs were in favor of regulations regarding Ddry chemical fire extinguishers (77.3%), fire detectors (44.6%), fire hoses (44.4%), gaseous agent fire extinguisher (40.6%), automatic descending life lines (36.2%), exit lights (35.9%), air respirators (35.9%), extinguishing systems for residential cooking facilities (33.9%), automatic spray-type extinguishing units (33.9%), emergency lights (31.2%), and gas leakage detectors (30.7%). Especially, among these, dry chemical fire extinguishers (60.0%), detectors (20.0%), and fire hose (18.8%) were identified as the fire products primarily in need of maintenance legislation. The general consensus is that fire products older than 10 years need to be replaced. Based on the survey results, there was general agreement that fire product life expectancy is in need of legislation. This study recommends the introduction of fire product life expectancy legislation in phases.

Smoke Control Performance of a Serial Structure Using "CONTAM" (CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구)

  • Kim, Mi-Seon;Seo, Dong-Gil;Gu, Seon-Hwan;Yoo, Young-Min;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.53-62
    • /
    • 2019
  • A recent trend shows that more buildings are being constructed as mixed-use (residential and commercial) properties for efficient land use. This has led to an increased frequency in the occurrence of fires and the associated potential risks. In particular, in case of high-rise apartments, at least one of the elevators in each building is installed for evacuation purposes separately from the emergency elevator; therefore, for a combined ancillary room and emergency elevator platform situation, the structure is inevitably in series with the evacuation elevator platform. Thus, a proposal for a new type of ventilation zone based on existing national fire safety codes is required to achieve smoke control performance. To this end, the air egress velocity and differential pressure of each ventilation zone are checked using the "CONTAM" software; further, an alternative is proposed to secure smoke control performance for series structures.

Fire Resistance Performance of Load Bearing Hybrid Panel Infilled with Light-weight Formed Mortar (복합스터드에 경량기포모르터를 충전한 내력벽체의 내화성능 비교연구)

  • Park, Keum Sung;Bae, Kyu Woong;Kang, Hyun Sik;Lim, Seo Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2007
  • The purpose of this paper is to evaluate the fire resistant performances of load-bearing wall using both composite and steel stud panel infilled with light-weight formed mortar under axial loading according to KS F 2257(1999). The minimum requirement of 2 hours fire resistant rating is needed for the residential and commercial buildings under the fire regulation of Korea. From test results, it is found that two types of specimen composed of the hybrid stud and steel stud panel filled with light-weight formed mortar fited in with the requirement of 2 hours fire resisting rate for the load-bearing wall. In the conclusions, the specimen with hybrid stud shows predominating fire-resistant performance on the adiabatic effects rather than that of the steel stud specimen.

A Study on the Ventilation Performance and Fire Characteristics with Different Types of Openings in External Wall of One Side Corridor Type Apartment (편복도형 아파트의 복도 외벽체 개구부 형태에 따른 환기성능 및 화재특성에 관한 연구)

  • Ko, Myeong Jin;Choi, Do Sung;Do, Jin Seok
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The objective of this study is to verify the safety in case of fire and change of residential environment for different wall construction approaches in a stairways apartment house. In order to confirm that case_1, which is current case that most of wall is opened and the case 2, which upper part of wall is limitedly opened are compared and analyzed based on simulations of fire, escape and natural ventilation performance. The analysis reveals that possible escape time for case 1 was more than 600 seconds and for case 2 was 195 seconds. Since the escape times for both cases were over 128 seconds, it would be reasonable to assume that every resident would escape. The simulation results on natural ventilation performance shows the air change per hour of case 1 and case 2 were .19n/h and .16n/h and there was 1.2 times difference. However, the difference was too insignificant and it could be seen as that different approaches on wall construction would not significantly influence on natural ventilation performance.

Modeling and simulation of large crowd evacuation in hazard-impacted environments

  • Datta, Songjukta;Behzadan, Amir H.
    • Advances in Computational Design
    • /
    • v.4 no.2
    • /
    • pp.91-118
    • /
    • 2019
  • Every year, many people are severely injured or lose their lives in accidents such as fire, chemical spill, public pandemonium, school shooting, and workplace violence. Research indicates that the fate of people in an emergency situation involving one or more hazards depends not only on the design of the space (e.g., residential building, industrial facility, shopping mall, sports stadium, school, concert hall) in which the incident occurs, but also on a host of other factors including but not limited to (a) occupants' characteristics, (b) level of familiarity with and cognition of the surroundings, and (c) effectiveness of hazard intervention systems. In this paper, we present EVAQ, a simulation framework for modeling large crowd evacuation by taking into account occupants' behaviors and interactions during an emergency. In particular, human's personal (i.e., age, gender, disability) and interpersonal (i.e., group behavior and interactions) attributes are parameterized in a hazard-impacted environment. In addition, different hazard types (e.g., fire, lone wolf attacker) and propagation patterns, as well as intervention schemes (simulating building repellent systems, firefighters, law enforcement) are modeled. Next, the application of EVAQ to crowd egress planning in an airport terminal under human attack, and a shopping mall in fire emergency are presented and results are discussed. Finally, a validation test is performed using real world data from a past building fire incident to assess the reliability and integrity of EVAQ in comparison with existing evacuation modeling tools.

A Study on the Effect of the Middle School Students` Residental Environment on their Personality (중학생의 주거환경이 인성특성에 미치는 영향)

  • 김진영;곽경숙
    • Journal of Korean Home Economics Education Association
    • /
    • v.13 no.3
    • /
    • pp.161-175
    • /
    • 2001
  • This study researched the interrelation between the development of the middle school student\` personality and their residential environments on 406 middle school students. The purpose of this research were to suggest a better residential environment as a desirable educational condition for making juveniles\` sound self-realization. The results of this research were as follows. 1. According to the their parents\` social status on middle school students\` personality the students. especially their parents had a service and technical expert official job of a better academic career showed an excellent score in personality. 2. According to the relation between the residential environment on their personality. it was said that the students. (1) who had their own study room at their own house. (2) who had a better house equipment and relatively a safety from fire danger. (3) who were living at the house which had been equipped a ventilation and sound isolation. were higher in the Personality score than any other groups. 3. According to the neighborhood and their personality the students who were living in some comfortable environments such as the divided collect of trash and the neighborhood natural surroundings skewed a high score in personality.

  • PDF

A Case Study on the Applied Ventilation System to the High-rise Residential Buildings (초고층 주거용 건축물에 적용된 환기시스템에 관한 사례 연구)

  • Kim, Ok;Kim, Nam-Gyu;Park, Jin-Chul;Rhee, Eon-Ku
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.381-386
    • /
    • 2006
  • This study is to research application cases of domestic ventilation system for developing ventilation system which is energy-saving and improve Indoor Air Quality and to research application possibility of foreign hybrid ventilation system. This is a basic research data of developing ventilation system for energy saying and improving indoor quality which that research the function and a feature of the ventilation system which is applied in five domestic skyscrapers over 30 floors, and research application instances and features of foreign hybrid ventilation system.

  • PDF

Performance Analysis of the the Single Alarm Detector in the Rooms of Single Houses by Computer Simulation (시뮬레이션을 통한 주거공간 단독경보형감지기의 성능 분석)

  • Lim, Geun-Joo;Park, Sang-Cheon;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.29-35
    • /
    • 2020
  • This study was conducted to examine the performance in the space for a single alarm type detector installed in a single house. Three types of houses were used, including two types of one-story and two-story houses. A computer simulation program was used to predict the sound pressure level in response to the occurrence of an alarm sound in a residential space. The characteristics of the sound source applied to the simulation were directly measured and used as input data. As a result of simulation, it was found that the sound pressure level in the kitchen and living room generally met the standard when the alarm sound of the detector occurred. However, the sound pressure level in the bedroom was predicted to be at least 20 dB (A) lower than the American Fire Protection Association standard of 75 dB (A). Therefore, a plan should be prepared to maintain a sufficient sound level in the bedroom space inside the house, and efforts will be needed to ensure safe evacuation in case of fire by establishing relevant standards.

Development of an Anti-Freezing Heating Cable Temperature Controller and Its Power Saving Effects Analysis (동파방지 발열선용 온도제어기 개발 및 전기에너지 절감 효과 분석)

  • Lee, Kihong;Lee, Jaejin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.101-106
    • /
    • 2014
  • Although anti-freezing heating cable has been widely installed in most residential boiler pipe, there were excessive energy consumption and fire risk due to inadequate temperature control. In this paper, a new energy saving fire risk-free controller was developed by using microprocessing operation which include detection of not only boiler room temperature but also pipe surface one. Its actual effect has been verified to save more than a half of the energy consumption comparing to conventional controller through temperature and humidity chamber experiment.