• Title/Summary/Keyword: Research building

Search Result 10,723, Processing Time 0.046 seconds

An Experimental Study on Flexural Performance Evaluation of C-Shaped Steel-Timber Composite Beams (C형 강재-목재 합성보의 휨성능 평가에 관한 실험 연구)

  • Oh, Keunyeong;Lee, Sang-Sup;Park, Keum-Sung;Boo, Yoon-Seob
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.331-341
    • /
    • 2024
  • In this study, the flexural strength and ductility of steel-timber composite beams were evaluated to enhance the structural performance of glued-laminated timber beams. Three specimens were fabricated, including one reference glulam beam and two composite beams. The composite beams were constructed by attaching steel sections to the glulam beam using either liquid adhesive or screws. The experimental results showed that the structural performance of the steel-timber composite beams was approximately 2-3 times higher than the reference glulam beam, indicating that both flexural strength and ductility were sufficiently ensured. Notably, the specimen constructed with liquid adhesive demonstrated superior structural performance compared to the screw-attached specimen.

Building System Analysis and Integration: Case Study on Richards Medical Research Building (건물시스템의 분석과 통합 방법에 관한 연구: 리차즈 의학 연구소 건물의 사례분석을 중심으로)

  • Choi, Joon-Sung;Im, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1444-1451
    • /
    • 2011
  • The purpose of this paper is to provide an understanding of building systems and to propose methods of building system analysis and integration. Building components are classified into four major systems; structure, mechanical, envelope, and interior system. There are 11 combinations between major systems. Three integration modes(physical, visual, and functional integration) and 12 integration strategies are proposed. A case study of Richards Medical Research Buildings designed by Louis I. Kahn was conducted from the perspective of building system analysis and integration.

Study on Field Experiment of Stack Effect Reduction in Stairwell of Building (건축물 계단에서의 연돌효과 저감방안에 대한 현장실험 연구)

  • Kim, Jung-Yup;Kim, Ji-Seok;Lee, Su-Gak
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.484-490
    • /
    • 2015
  • The winter stack effect that occurs in vertical construction passages such as the stairwell or elevator shaft of a high-rise building negatively affects living environments, energy usage, and personal safety; therefore, a mitigation of the stack effect is required to improve building conditions. Recently, circulation-type facilities that comprise the usage of air blowers and vertical ducts were proposed as part of a mechanical approach to quantitatively control the stack effect. In this study, these circulation-type facilities were installed in a building stairwell and the performance of the device was evaluated during its operation. A numerical-analysis result was obtained under the test conditions using a network-model-based, numerical-analysis method, and the result was then used for a comparison with the test result.

A Study on Estimation of Cooling Load Using Forecasted Weather Data (집단 건물 면적을 이용한 시간별 냉방부하 파라미터 설정 및 예측에 관한 연구)

  • Han, Kyu-Hyun;Yoo, Seong-Yeon;Lee, Je-Myo;Song, Yang-Sup
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.440-445
    • /
    • 2008
  • In this paper, new methodology is proposed to estimate the cooling load using areas of building group and predicted weather data. Only three parameters such as maximum, minimum temperature and building area are necessary to obtain hourly distribution of cooling load for the next day. The maximum and minimum temperature that are used for input parameters can be obtained from forecasted weather data. The areas of building group are used for setting several parameters that are used for estimate cooling loads. Benchmarking building(research building) is selected to validate the performance of the proposed method, and the estimated cooling loads in hourly bases are calculated and compared with the measured data for benchmarking building. The estimated results show fairly good agreement with the measured data for benchmarking building.

  • PDF

Study on wind-induced vibration response of Jiayuguan wooden building

  • Teng Y. Xue;Hong B. Liu;Ting Zhou;Xin C. Chen;Xiang Zhang;Zhi P. Zou
    • Wind and Structures
    • /
    • v.37 no.3
    • /
    • pp.245-254
    • /
    • 2023
  • In this paper, the wind-induced response of Jiayuguan wooden building (world cultural heritage) in Northwest China was studied. ANSYS finite element software was used to establish four kinds of building models under different working conditions and carry out modal analysis. The simulation results were compared with the field dynamic test results, obtaining the model which reflects the real vibration characteristics of the wooden tower. Time history data of fluctuating wind speed was obtained by MATLAB programming. Time domain method and ANSYS were used to analyze the wind-induced vibration response time history of Jiayuguan wooden building, obtaining the displacement time history curve of the structure. It was suggested that the wind-induced vibration coefficient of Jiayuguan wooden building is 1.76. Through analysis of the performance of the building under equivalent static wind load, the maximum displacement occurs in the three-story wall, gold column and the whole roof area, and the maximum displacement of the building is 5.39 cm. The ratio of the maximum stress value to the allowable value of wood tensile strength is 45 %. The research results can provide reference for the wind resistant design and protection of ancient buildings with similar structure to Jiayuguan wooden tower.

A Evaluation on Flexural Behavior for Hollow Core Slab of Fire Resistance section for Residence Building (주거용 내화단면 중공슬래브의 휨거동 평가)

  • Boo, Yoon-Seob;Bae, Kyu-Woong;Shin, Sang-Min
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.2
    • /
    • pp.61-68
    • /
    • 2023
  • A two-hour fire-resistance PC hollow slab for residential use was developed to secure structural and fire-resistance performance and to be applied to the general building and apartment housing markets. Compared to the existing hollow slab, in order to secure the same or better structural performance and economic feasibility by reducing the quantity, it was attempted to secure the fire resistance performance by reducing the concrete filling rate in the cross section and adjusting the thickness of the upper and lower flanges by optimizing the hollow shape in the cross section of the slab. For structural performance evaluation, experiments were performed on PC hollow slabs by varying the member thickness and the presence or absence of overlaid concrete, and all of the experimental results showed that the design strength was sufficiently exhibited and that stability during construction was possible. The developed synthetic PC hollow slab has secured fire resistance and residential performance so that it can be applied to all buildings, and it is intended to be immediately applied to the field.

A Study on Comparing and Analyzing Domestic and Foreign Green Building Certification Criteria for School Facility -Focused on the G-SEED and LEED, BREEAM- (국내외 학교시설 녹색 건축 인증제도의 비교분석에 관한 기초연구 -G-SEED와 LEED, BREEAM을 중심으로-)

  • Lee, Jong-Kuk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.13 no.3
    • /
    • pp.15-22
    • /
    • 2014
  • Proceeded with a research with basic data about the qualification standard improvement scheme about the environment school architecture in which a comparison analyze the specialized field of BREEAM system of LEED of the hit environment building qualification standard G-SEED of the domestic and U.S Green Building Counci evaluated with the certification system of the world top class and Building Research Establish, essential item, and mark distribution and weight in this study at this and which I hit with a domestic afterward. The school facility with a hub among the equipment receiving the hit environmental qualification standard, and the range of this research does LEED of the domestic green building certification system February is revised in 2013 G-SEED and which US and BREEAM in UK with a range. The way of the research checked the environment school building certification system and situation hit home and abroad, and a comparison analyze the division of the specialized field of each country qualification standard, essential item, and mark distribution and weight.

Performance indicator of the atmospheric corrosion monitor and concrete corrosion sensors in Kuwait field research station

  • Husain, A.;Al-Bahar, Suad Kh.;Salam, Safaa A. Abdul
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.981-994
    • /
    • 2016
  • Two field research stations based upon atmospheric corrosivity monitoring combined with reinforced concrete corrosion rate sensors have been established in Kuwait. This was established for the purpose of remote monitoring of building materials performance for concrete under Kuwait atmospheric environment. The two field research sites for concrete have been based upon an outcome from a research investigation intended for monitoring the atmospheric corrosivity from weathering station distributed in eight areas, and in different regions in Kuwait. Data on corrosivity measurements are essential for the development of specification of an optimized corrosion resistance system for reinforced concrete manufactured products. This study aims to optimize, characterize, and utilize long-term concrete structural health monitoring through on line corrosion measurement and to determine the feasibility and viability of the integrated anode ladder corrosion sensors embedded in concrete. The atmospheric corrosivity categories supported with GSM remote data acquisition system from eight corrosion monitoring stations at different regions in Kuwait are being classified according to standard ISO 9223. The two nominated field sites where based upon time of wetness and bimetallic corrosion rate from atmospheric data where metals and rebar's concrete are likely to be used. Eight concrete blocks with embeddable anodic ladder corrosion sensors were placed in the atmospheric zone adjacent to the sea shore at KISR site. The anodic ladder corrosion rate sensors for concrete were installed to provide an early warning system on prediction of the corrosion propagation and on developing new insights on the long-term durability performance and repair of concrete structures to lower labor cost. The results show the atmospheric corrosivity data of the environment and the feasibility of data retrieval of the corrosion potential of concrete from the embeddable sets of anodic ladder corrosion sensors.

A Comparative Study on the Assessment Items of Korea's Apartment Building Certification Systems (국내 공동주택 관련 인증제도의 세부 항목에 대한 비교 분석에 관한 연구)

  • Jung, Ji-Na;Tae, Choon-Seob;Yang, Jeong-Hoon;Park, Sang-Dong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.116-123
    • /
    • 2010
  • A various building certification systems are being enforced in Korea. However, the enforcement of many building certification systems has brought on the concerned people's confusion and the operation of various building certification systems which have similar assesment items causes much time and economical losses. Therefore, in this paper, the features of the GBCS(Green Building Certification System), Housing Performance Indication System, Building Energy Rating System, and Green Home Standard and Performance Evaluation System are compared and the correlations among each building certification system are analysed. As a result, it is presented that a considerable number of assessment items were so similar and identical that integration of building certification systems is needed for effective operation of these systems.

Case Study on the Building Organization of Medibio Research Laboratory Facilities in Research-driven Hospital (연구중심병원 의생명연구원의 실험실 구성 사례 조사)

  • Kim, Young-Aee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.95-104
    • /
    • 2018
  • Healthcare technology has been growing and fostering cooperation between industry, university and hospitals as growth engines in korea. So, the medibio research institutes in hospital have been constructed to promote research and industrialization centering on healthcare technology. The purpose of this study is to investigate the cases of research institutes in hospitals, and search the characteristics of building organization of medibio research laboratory facilities. Case study is investigated by floor plan, homepage and site visits about five research institutes selected in research-driven hospitals. The facility title and size of research laboratory is originated from site area and research building location. The building function include not only the research lab and business office reflecting on the development platform, and but assembly and meeting room in the ground level. Laboratory floor plans have three types, rectangular, rectangular+linear and linear type, one is traditional and efficient, the others are people and friendly. And building core types are correlated with lab space unit modules, single and double side core are shown in rectangular type. All the laboratories are open lab, composed with laboratory bench and research note writing desk facing the lab service and enclosed lab-support area. And they have communication space looking as warm and cozy common area for the innovation, convergence and collaboration. As the high risk of contamination and high standard for safety and security, equipment and facilities are well managed with biological environment including BSC, fume hood, PCR classification, eye washing and emergency shower.