• Title/Summary/Keyword: Repetitive Sampling

Search Result 36, Processing Time 0.024 seconds

New Attributes and Variables Control Charts under Repetitive Sampling

  • Aslam, Muhammad;Azam, Muhammad;Jun, Chi-Hyuck
    • Industrial Engineering and Management Systems
    • /
    • v.13 no.1
    • /
    • pp.101-106
    • /
    • 2014
  • New control charts under repetitive sampling are proposed, which can be used for variables and attributes quality characteristics. The proposed control charts have inner and outer control limits so that repetitive sampling may be needed if the plotted statistic falls between the two limits. Particularly, the new np and variable X-bar control charts under repetitive sampling are considered in detail. The in-control and out-of-control average run lengths are analyzed according to various process shifts. The performance of the proposed control charts is compared with the existing np and the X-bar control charts in terms of the average run lengths.

Deadbeat Control with a Repetitive Predictor for Three-Level Active Power Filters

  • He, Yingjie;Liu, Jinjun;Tang, Jian;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.583-590
    • /
    • 2011
  • Three-level NPC inverters have been put into practical use for years especially in high voltage high power grids. This paper researches three-level active power filters (APFs). In this paper a mathematical model in the d-q coordinates is presented for 3-phase 3-wire NPC APFs. The deadbeat control scheme is obtained by using state equations. Canceling the delay of one sampling period and providing the predictive value of the harmonic current is a key problem of the deadbeat control. Based on this deadbeat control, the predictive output current value is obtained by the state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by the repetitive predictor synchronously. The repetitive predictor can achieve a better prediction of the harmonic current with the same sampling frequency, thus improving the overall performance of the system. The experiment results indicate that the steady-state accuracy and the dynamic response are both satisfying when the proposed control scheme is implemented.

A Variables Repetitive Group Sampling Plan for Minimizing Average Sample Number (평균 샘플 수 최소화를 통한 계량형 반복 샘플링 검사의 설계)

  • Park, Heekon;Moon, Young-gun;Jun, Chi-Hyuck;Balamurali, S.;Lee, Jaewook
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2004
  • This paper proposes the variables repetitive group sampling plan where the quality characteristic following normal distribution has upper or lower specification limit. The problem is formulated as a non-linear programming problem where the objective function to minimize is the average sample number and the constraints are related to lot acceptance probabilities at acceptable quality level (AQL) and limiting quality level (LQL) under the operating characteristic curve. Sampling plan tables are constructed for the selection of parameters indexed by AQL and LQL in the cases of known standard deviation and unknown standard deviation. It is shown that the proposed sampling plan significantly reduces the average sample number as compared with the single or the double sampling plan.

Adaptive Repetitive Control for an Eccentricity Compensation of Optical Disk Drive (광 디스크 드라이브의 편심 보상을 위한 적응 반복 제어)

  • Seo, Sam-Jun;Kim, Dong-Won;Park Gwi-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.135-142
    • /
    • 2005
  • This paper presents an adaptive repetitive control scheme for optical disk drives to track a variable periodic reference signal. Periodic disturbances can be adequately attenuated using the concept of repetitive control, provided the period is known. Because optical disk drives support various speeds, they have the varying periodic disturbances. Based on repetitive control to change sampling frequency to follow the change of reference period, an adaptive repetitive control is proposed in order to deal with such disturbances. The proposed control consists of the repetitive controller and the frequency generator. The former uses a varying sampler operating at fixed multiple times of the disturbance frequency and the latter generates the changeable sampling frequency based on the disturbance frequency. The experimental results on the control of an optical disk drive demonstrate the effectiveness of the proposed schemes and the improvement of random access time as well.

Adaptive Repetitive Control for an Eccentricity Compensation of Optical Disk Driver (광 디스크 기기의 편심 보상을 위한 적응 반복 재어)

  • Kim, Jeong-Hun;Sim, Il-Ju;Park, Gwi-Tae;Roh, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2146-2148
    • /
    • 2003
  • This paper present a modified repetitive control scheme for an optical storage system to track a periodic reference signal with dynamic change in period. Periodic disturbances can be adequately attenuated using the concept of repetitive control, provided the period is know. An optical storage system supports various speeds. To deal with time varying periodic disturbances, an proposed repetitive controller is turned based on repetitive control to change sampling frequency to follow the change of reference Period. A modified repetitive control scheme is proposed and implement on experimental set up of a optical disk driver.

  • PDF

Analysis and Application of Repetitive Control Scheme for Three-Phase Active Power Filter with Frequency Adaptive Capability

  • Sun, Biaoguang;Xie, Yunxiang;Ma, Hui;Cheng, Li
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.618-628
    • /
    • 2016
  • Active power filter (APF) has been proved as a flexible solution for compensating the harmonic distortion caused by nonlinear loads in power distribution power systems. Digital repetitive control can achieve zero steady-state error tracking of any periodic signal while the sampling points within one repetitive cycle must be a known integer. However, the compensation performance of the APF would be degradation when the grid frequency varies. In this paper, an improved repetitive control scheme with frequency adaptive capability is presented to track any periodic signal with variable grid frequency, where the variable delay items caused by time-varying grid frequency are approximated with Pade approximants. Additionally, the stability criterion of proposed repetitive control scheme is given. A three-phase shunt APF experimental platform with proposed repetitive control scheme is built in our laboratory. Simulation and experimental results demonstrate the effectiveness of the proposed repetitive control scheme.

Precision servo control of a computer hard disk (컴퓨터 하드 디스크의 정밀 서보 제어)

  • 전도영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.286-289
    • /
    • 1996
  • Two servo control algorithms are suggested to reduce the tracking error of a computer hard disk drive. One is the repetitive control to reduce the repeatable tracking error which is not explicitly taken into account in the design of a conventional controller. This algorithm was successfully applied to a commercial disk using a fixed point DSP. The other is the multi-rate sampling control which generates the control output between each sampling times since the sampling time of hard disk drives is limited. These algorithms were shown effectively to reduce tracking errors.

  • PDF

A Robust Background Subtraction Algorithm for Dynamic Scenes based on Multiple Interval Pixel Sampling (다중 구간 샘플링에 기반한 동적 배경 영상에 강건한 배경 제거 알고리즘)

  • Lee, Haeng-Ki;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.31-36
    • /
    • 2020
  • Most of the background subtraction algorithms show good performance in static scenes. In the case of dynamic scenes, they frequently cause false alarm to "temporal clutter", a repetitive motion within a certain area. In this paper, we propose a robust technique for the multiple interval pixel sampling (MIS) algorithm to handle highly dynamic scenes. An adaptive threshold scheme is used to suppress false alarms in low-confidence regions. We also utilize multiple background models in the foreground segmentation process to handle repetitive background movements. Experimental results revealed that our approach works well in handling various temporal clutters.

Repetitive Load Prediction for Second Order Deadbeat Response Applied to UPS Inverter (UPS inverter의 2차 데드비트 응답을 위한 반복부하예측기법)

  • 최재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.339-342
    • /
    • 2000
  • Repetitive Load Prediction is proposed for the UPS inverter application of the second order deadbeat controller which is robust against the calculation time delay and the parameter variation and which gets fast response against the load variation. The proposed technique predicts the load current ahead of two sampling time using that the load current is periodic. This is effective under nonlinear load condition. The proposed technique is derived theoretically and verified through simulation and experimental result.

  • PDF

A PI Control Algorithm with Zero Static Misadjustment for Tracking the Harmonic Current of Three-Level APFs

  • He, Yingjie;Liu, Jinjun;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.175-182
    • /
    • 2014
  • Tracking harmonic current quickly and precisely is one of the keys to designing active power filters (APF). In the past, the current state feedback decoupling PI control was an effective means for three-phase systems in the current control of constant voltage constant frequency inverters and high frequency PWM reversible rectifiers. This paper analyzes in detail the limitation of the conventional PI conditioner in the APF application field and presents a novel PI control method. Canceling the delay of one sampling period and the misadjustment for tracking the harmonic current is the key problem of this PI control. In this PI control, the predictive output current value is obtained by a state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by a repetitive predictor synchronously. The repetitive predictor can achieve better predictions of the harmonic current. By this means, the misadjustment of the conventional PI control for tracking the harmonic current is cancelled. The experiment results with a three-level NPC APF indicate that the steady-state accuracy and dynamic response of this method are satisfying when the proposed control scheme is implemented.