DOI QR코드

DOI QR Code

A PI Control Algorithm with Zero Static Misadjustment for Tracking the Harmonic Current of Three-Level APFs

  • He, Yingjie (State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University) ;
  • Liu, Jinjun (State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University) ;
  • Wang, Zhaoan (State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University) ;
  • Zou, Yunping (Dept. of Electrical and Electronic Eng., Huazhong University of Science & Technology)
  • Received : 2013.04.24
  • Published : 2014.01.20

Abstract

Tracking harmonic current quickly and precisely is one of the keys to designing active power filters (APF). In the past, the current state feedback decoupling PI control was an effective means for three-phase systems in the current control of constant voltage constant frequency inverters and high frequency PWM reversible rectifiers. This paper analyzes in detail the limitation of the conventional PI conditioner in the APF application field and presents a novel PI control method. Canceling the delay of one sampling period and the misadjustment for tracking the harmonic current is the key problem of this PI control. In this PI control, the predictive output current value is obtained by a state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by a repetitive predictor synchronously. The repetitive predictor can achieve better predictions of the harmonic current. By this means, the misadjustment of the conventional PI control for tracking the harmonic current is cancelled. The experiment results with a three-level NPC APF indicate that the steady-state accuracy and dynamic response of this method are satisfying when the proposed control scheme is implemented.

Keywords

References

  1. P. Kumar and A. Mahajan, "Soft computing techniques for the control of an active power filter," IEEE Trans. Power Del., Vol. 24, No. 1, pp. 452- 461, Jan. 2009. https://doi.org/10.1109/TPWRD.2008.2005881
  2. H. A. Ramos-Carranza, A. Medina and G. W. Chang, "Real-Time Shunt Active Power Filter Compensation," IEEE Trans. Power Del., Vol. 23, No. 4, pp. 2623-2625, Oct. 2008. https://doi.org/10.1109/TPWRD.2008.2002836
  3. B. Singh and V. Verma, "Selective compensation of power-quality problems through active power filter by current decomposition," IEEE Trans. Power Del., Vol. 23, No. 2, pp. 792-799, Apr. 2008. https://doi.org/10.1109/TPWRD.2007.911108
  4. S. Hirve, K. Chatterjee, B. G. Fernandes, M. Imayavaramban, and S. Dwari, "PLL-Less Active Power Filter Based on One-Cycle Control for Compensating Unbalanced Loads in Three-Phase Four-Wire System," IEEE Trans. Power Del., Vol. 22, No. 4, pp. 2457-2465, Oct. 2007. https://doi.org/10.1109/TPWRD.2007.893450
  5. N. Akira, I. Takahashi, and H. Akagi, "A new neutral-point-clamped PWM inverter," IEEE Trans. Ind. Applicat., Vol. 17, No. 3, pp. 518-523, Sep. 2007.
  6. H. Akagi and R. Kondo, "A transformerless hybrid active filter using a three-level PWM converter for a medium-voltage motor drive," in Proc. ECCE, pp. 1732-1739, 2009.
  7. H. Akagi and T. Hatada, "Voltage Balancing Control for a Three-Level Diode-Clamped Converter in a Medium-Voltage Transformerless Hybrid Active Filter," IEEE Trans. Power Del., Vol. 24, No. 3, pp. 571-579, Mar. 2009. https://doi.org/10.1109/TPEL.2009.2012528
  8. H. Rudnick, J. Dixon, and L. Moran, "Delivering clean and pure power," IEEE Power and Energy Magazine. Vol. 1, No. 5, pp. 32-40, Sep./Oct. 2003.
  9. M. C. Wong, J. Tang, and Y. D. Han, "Cylindrical coordinate control of 3-D PWM technology in 3-phase 4-wire tri-level inverter," IEEE Trans. Power Electron., Vol. 18, No. 1, pp. 208 -220, Jan. 2003. https://doi.org/10.1109/TPEL.2002.807133
  10. N. Y. Dai, M. C. Wong, and Y. D. Han, "Application of a three-level NPC inverter as a three-phase four-wire power quality compensator by generalized 3DSVM," IEEE Trans. Power Electron., Vol. 21, No. 2, pp. 440 - 449, Mar. 2006. https://doi.org/10.1109/TPEL.2005.869755
  11. M. Basu, S. P. Das, and G. K. Dubey, "Parallel converter scheme for high-power active power filters," IEE Proceedings Electric Power Applications, Vol. 151, No. 4, pp. 460-466, Jul. 2004. https://doi.org/10.1049/ip-epa:20040211
  12. O. Vodyakho and C. C. Mi, "Three-level inverter-based shunt active power filter in three-phase three-wire and four-wire systems,"IEEE Trans. Power Electron., Vol. 24, No. 5, pp. 1350-1363, May 2009. https://doi.org/10.1109/TPEL.2009.2016663
  13. H. Akagi, S. Inoue, and T. Yoshii,"Control and performance of a transformerless cascade PWM STATCOM with star configuration," IEEE Trans. Ind. Applicat., Vol. 43, No.4, pp.1041-1049, Jul./Aug. 2007. https://doi.org/10.1109/TIA.2007.900487
  14. L. Maharjan, S. Inoue, and H. Akagi, "A transformerless energy storage system based on a cascade multilevel PWM converter with star configuration," IEEE Trans. Ind. Applicat., Vol. 44, No. 5, pp. 1621-1630, Sep./Oct. 2008. https://doi.org/10.1109/TIA.2008.2002180
  15. H. Akagi, H. Fujita, S. Yonetani, and Y. Kondo, "A 6.6-kV transformerless STATCOM based on a five-level diode-clamped PWM converter: System design and experimentation of a 200-V 10-kVA laboratory model," IEEE Trans. Ind. Applicat., Vol. 44, No. 2, pp. 672-680, Oct. 2008. https://doi.org/10.1109/TIA.2008.916713
  16. Z. Zhou, P. J. Unsworth, P. M. Holland, and P. Igic, "Design and analysis of a feedforward control scheme for a three-phase voltage source pulse width modulation rectifier using sensorless load current signal," IET Proceedings Power Electronics, Vol. 2, No. 4, pp. 421- 430, Jul. 2009. https://doi.org/10.1049/iet-pel.2008.0058
  17. K. Lee, T. M. Jahns, T. A. Lipo, V. Blasko, and R. D. Lorenz, "Observer-based control methods for combined source-voltage harmonics and unbalance disturbances in PWM voltage-source converters," IEEE Trans. Ind. Applicat., Vol. 45, No. 6, pp. 2010-2021, Nov./Dec. 2009. https://doi.org/10.1109/TIA.2009.2031854
  18. A. Yoo and S. K. Sul, "Design of flux observer robust to interior permanent-magnet synchronous motor flux variation," IEEE Trans. Ind. Applicat., Vol. 45, No. 5, pp. 1670-1677, Sep./Oct. 2009. https://doi.org/10.1109/TIA.2009.2027516
  19. H. Fujita, "A single-phase active filter using an h-bridge PWM converter with a sampling frequency quadruple of the switching frequency," IEEE Trans. Power Electron., Vol. 24, No. 4, pp. 934-941, Jun. 2009. https://doi.org/10.1109/TPEL.2008.2009302
  20. K. Zhang, Y. Kang, J. Xiong, and J. Chen, "Deadbeat control of PWM inverter with repetitive disturbance prediction," in Proc. APEC, pp. 1026-1031, 1999.
  21. O. Vodyakho, D. Hackstein, A. Steimel, and T. Kim, "Novel direct current-space-vector control for shunt active power filters based on the three-level inverter," IEEE Trans. Power Electron., Vol. 23, No. 4, pp. 1668-1678, Feb. 2008. https://doi.org/10.1109/TPEL.2008.925181
  22. M. Bojrup, P. Karlsson, M. Alakula, and L. Gertmar, "A multiple rotating integrator controller for active filters," in Proc. EPE., pp. 756 -762, 1999.
  23. S. Fukuda and R. Imamura. "Application of a sinusoidal internal model to current control of three-phase utility-interface converters," IEEE Trans. Ind. Electron., Vol.50, No. 2, pp. 420-426, Apr. 2005.
  24. P. Kirawanich and R. M. O'Connell, "Fuzzy logic control of an active power line conditioner," IEEE Trans. Power Electron., Vol. 19, No. 6, pp. 1574-1585, Nov. 2004. https://doi.org/10.1109/TPEL.2004.836631
  25. N. Celanovic and D. Voroyevich, "A comprehensive study of neutral-point voltage balancing problem in three-level neutral-point-clamped voltage source PWM inverters," IEEE Trans. Power Electron., Vol. 15, No. 2, pp. 242-249, Mar. 2000. https://doi.org/10.1109/63.838096

Cited by

  1. Predictive Control Method With Future Zero-Sequence Voltage to Reduce Switching Losses in Three-Phase Voltage Source Inverters vol.30, pp.3, 2015, https://doi.org/10.1109/TPEL.2014.2304719
  2. A Load Compensator Based on One-Cycle Control with Plug-In Repetitive Control vol.15, pp.2, 2015, https://doi.org/10.6113/JPE.2015.15.2.443