• 제목/요약/키워드: Relative energy

Search Result 2,031, Processing Time 0.034 seconds

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.

Analysis of Hydrodynamics in a Directly-Irradiated Fluidized Bed Solar Receiver Using CPFD Simulation (CPFD를 이용한 태양열 유동층 흡열기의 수력학적 특성 해석)

  • Kim, Suyoung;Won, Geunhye;Lee, Min Ji;Kim, Sung Won
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.535-543
    • /
    • 2022
  • A CPFD (Computational particle fluid dynamics) model of solar fluidized bed receiver of silicon carbide (SiC: average dp=123 ㎛) particles was established, and the model was verified by comparing the simulation and experimental results to analyze the effect of particle behavior on the performance of the receiver. The relationship between the heat-absorbing performance and the particles behavior in the receiver was analyzed by simulating their behavior near bed surface, which is difficult to access experimentally. The CPFD simulation results showed good agreement with the experimental values on the solids holdup and its standard deviation under experimental condition in bed and freeboard regions. The local solid holdups near the bed surface, where particles primarily absorb solar heat energy and transfer it to the inside of the bed, showed a non-uniform distribution with a relatively low value at the center related with the bubble behavior in the bed. The local solid holdup increased the axial and radial non-uniformity in the freeboard region with the gas velocity, which explains well that the increase in the RSD (Relative standard deviation) of pressure drop across the freeboard region is responsible for the loss of solar energy reflected by the entrained particles in the particle receiver. The simulation results of local gas and particle velocities with gas velocity confirmed that the local particle behavior in the fluidized bed are closely related to the bubble behavior characterized by the properties of the Geldart B particles. The temperature difference of the fluidizing gas passing through the receiver per irradiance (∆T/IDNI) was highly correlated with the RSD of the pressure drop across the bed surface and the freeboard regions. The CPFD simulation results can be used to improve the performance of the particle receiver through local particle behavior analysis.

Effects of Varying Levels of Dietary Metabolizable Energy and Crude Protein on Growth Performance and Carcass Characteristics in Layer-type Growing Male Chicks (사료 내 대사 에너지 및 조단백질 수준이 산란종 수평아리의 성장성적과 도체특성에 미치는 영향)

  • Yun, Jeong-Geun;Kim, Hong-Rae;Oh, Sung-Taek;Zheng, Lan;Choi, Young-In;Choo, Yun-Kyung;An, Byoung-Ki;Lee, Sung-Ki;Kang, Chang-Won
    • Korean Journal of Poultry Science
    • /
    • v.39 no.2
    • /
    • pp.87-95
    • /
    • 2012
  • This experiment was conducted to investigate the effects of varying levels of metabolizable energy (ME) and crude protein (CP) on growth performance and carcass characteristics in layer-type growing male chicks. Nine hundred 1-d-old Hy-Line Brown male chicks were randomly allocated to 30 pens in a $2{\times}3$ factorial design. The experimental diets contained 2 levels of ME (2,800 kcal/kg and 2,950 kcal/kg) in combination with 3 levels of CP (17%, 18.5%, and, 20%). A significant interaction of ME and CP on feed intake was observed (p<0.05). No interaction was observed between ME and CP for 53 d BW gain or FCR, which improved linearly with dietary CP levels (p<0.05). A significant interaction or tendency was observed between ME and CP levels. The intake of ME for 1 g BW gain was linearly decreased with increasing CP levels (p<0.001). The intake of CP per bird was significantly increased in low ME (2,800 kcal/kg) treatment than that of the high ME treatment (2,950 kcal/kg) (p<0.05), and dietary CP level had more influence on CP intake for gram BW gain than level of ME. The relative weights of liver, spleen, breast meat and, leg were not influenced by the dietary treatments. Serum BUN, albumin, creatinine, and the activities of GOT and GPT were not influenced significantly by the diet treatment. In conclusion, the growth performance in layer-type male chicks was linearly increased when the level of dietary CP increased. The ME and CP did not affect the carcass characteristics and blood profiles. Therefore, the optimum levels of dietary ME and CP to improve the growth were 2,800 kcal/kg and above 18.5% in layer-type growing male chicks, respectively.

A study on Palpation of the back-shu points (배유혈(背兪穴) 안진(按診)에 관(關)한 고찰(考察))

  • Hong, Mun-Yeup;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.155-173
    • /
    • 2000
  • The diagnosis in Oriental medicine is done by inspection, auscultation and olfaction, interrogation, four diagnostics of pulse feeling and palpation, and various system of identification like identification according to Qi(vital energy), Xue and body fluids, identification according to fair principles, identification according to principles of Wei, Qi, Ying and Xue, identification according to Sanjiao(the triple heater), identification according to four type physical constitution. Sometimes, symptoms and diagnosis techniques according to symptoms is selectively applied for the diagnosis. Among them the pulse feeling and palpation diagnosis technique using the sense of finger and palm of the hand is divided into feeling of pulse and palpation and pressing maneuver. Pressing maneuver is a diagnosis technique pressing and rubbing the affected part in order to attain data of identification including inside and outside condition of the body with regard to the nature, condition and relative seriousness of disease. There are palpation of the skin, palpation the hand and foot, palpation the chest and the abdomen, palpation shu points in pressing maneuver. The diagnosis of the Back Shu points is a technique to examine the change of disease condition from pressure ache, spontaneous ache, tension, relaxation, solidification revealed through channels and collaterals. I investigates starting disease and an attack of disease of twelve pulse and pulse condition through the study relative to the substance and technique of pressing maneuver, and adjusts diagnosis techniques of a region for acupuncture and matters to be attended. The conclusions are as follows. 1. The Shu or stream points in which pathogenic factors go are important to medical treatment of dormant diseases like bowels disease, cold symptom complex and insufficiency symptom complex. 2. Disease classified by system is diagnosed by the condition of process part like pro-trusion, cave-in, tension, relaxation, pressure ache through palpating the Shu or stream points, that is pressing upward or downward left and right sides of the backbone process by hands. 3. In real clinic pressing maneuver of one's back side is very important to patient's diagnosis treatment. Thus, pressing maneuver of one's back side have to be done without omission. 4. Diagnosis must be accomplished through the perception about the diversity of diagnosis technique of bowels disease, the exact knowledge about pressing maneuver of one's back side for enlargement of treatment range and rising of treatment rate, and pressing maneuver of the Shu or the stream points.

  • PDF

Air Cavity Effects on the Absorbed Dose for 4-, 6- and 10-MV X-ray Beams : Larynx Model (4-, 6-, 10-MV X-선원에서 공기동이 흡수선량에 미치는 효과 : 후두모형)

  • Kim Chang-Seon;Yang Dae-Sik;Kim Chul-Yong;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.393-402
    • /
    • 1997
  • Purpose : When an x-ray beam of small field size is irradiated to target area containing an air cavity, such as larynx, the underdosing effect is observed in the region near the interfaces of air and soft tissue. With a larynx model, air cavity embedded in tissue-equivalent material, this study is intonded for examining Parameters, such as beam quality, field size, and cavity size, to affect the dose distribution near the air cavity. Materials and Methods : Three x-rar beams, 4-, 6- and 10-MV, were employed to Perform a measurement using a 2cm $(width){\times}L$ (length in cm, one side of x-ray field used 2cm (height) air cavity in the simulated larynx. A thin window parallel-plate chamber connected to an electrometer was used for a dosimetry system. A ratio of the dose at various distances from the cavity-tissue interface to the dose at the same points in a homogeneous Phantom (ebservedlexpected ratio, O/E) normalized buildup curves, and ratio of distal surface dose to dose at the maximum buildup depth were examined for various field sizes. Measurement for cavity size effect was performed by varying the height (Z) of the air cavity with the width kept constant for several field sizes. Results : No underdosing effect for 4-MV beam for fields larger than $5cm\times5cm$ was found For both 6- and 10-MV beams, the underdosing portion of the larynx at the distal surface was seen to occur for small fields, $4cm\times4cm\;and\;5cm\times5cm$. The underdosed tissue was increased in its volume with beam energy even for similar surface doses. The relative distal surface dose to maximum dose was changed to 0.99 from 0.95, 0.92, and 0.91 for 4-, 6-, and 10-MV, respectively, with increasing field size, $4cm\times4cm\;to\;8cm\times8cm$, For 6- and 10-MV beams, the dose at the surface of the cavity is measured less than the predicted by about two and three percent. respectively. but decrease was found for 4-MV beam for $5cm\times5cm$ field. For the $4cm\timesL\timesZ$ (height in cm). varying depth from 0.0 to 4.8cm, cavity, O/E> 1.0 was observed regardless of the cavity size for any field larger than about $8cm\times8cm$. Conclusion : The magnitude of underdosing depends on beam energy, field size. and cavity size for the larynx model. Based on the result of the study. caution must be used when a small field of a high quality x-ray beam is irradiated to regions including air cavities. and especially the region where the tumor extends to the surface. Low quality beam. such as. 4-MV x-ray, and larger fields can be used preferably to reduce the risk of underdosing, local failure. In the case of high quality beams such as 6- and 10-MV x-rays, however. an additional boost field is recommended to add for the compensation of the underdosing region when a typically used treatment field. $8cm\times8cm$, is employed.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Effect of Magnetic Properties on the Zr contents of Sm(CO.688-xFe.242Cu.07Zr x)7.404 Sintered Magnets (Sm(CO.688-xFe.242Cu.07Zr x)7.404소결자석의 자기적 특성에 미치는 Zr의 영향)

  • Jung, Woo-Sang;Kim, Yoon-Bae;Jeung, Won-Young
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.5
    • /
    • pp.189-194
    • /
    • 2002
  • Microstructure and magnetic properties of Sm-Co sintered magnet were investigated with the variation of Zr content and their solution treatment and aging temperatures. The fraction of eutectic structure and the size of eutectic area decreased with increasing x value of cast Sm(C $O_{.688-x}$F $e_{.242}$C $u_{.07}$Z $r_{x}$)$_{7.404}$ alloys. On the other hand, x=0.022 ingot had finer dendritic structure compared to the other alloys. The sintered magnet of Sm(C $O_{.688-x}$F $e_{.242}$C $u_{.07}$Z $r_{x}$)$_{7.404}$ had well defined cell structure which is composed of cell boundary Sm $Co_{5}$ and cell interior S $m_2$Co/ssub 17/ phase. Cell boundary Sm $Co_{5}$ phase has 20nm thickness and its relative angle was 120$^{\circ}$ in x=0.018 and 0.022 alloys. Cell size was decreased with increasing Zr contents. But, x=0.026 alloy has diffuse cell boundary and irregular shape compared to x=0.022 and 0.018 alloys. Maximum value of coercive force and maximum energy Product were obtained from x=0.022 alloys. Optimum solution treatment temperature of Sm(C $O_{.688-x}$F $e_{.242}$C $u_{.07}$Z $r_{x}$)$_{7.404}$ alloy was 1170 $^{\circ}C$ and 1st aging temperature of two step aging process for higher coercivity was 850 $^{\circ}C$.

Assessment of nutritional status of patients with chronic obstructive pulmonary disease (만성 폐쇄성 폐질환 환자의 영양상태 평가)

  • Park, Kwang Joo;Ahn, Chul Min;Kim, Hyung Jung;Chang, Joon;Kim, Sung Kyu;Lee, Won Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.93-103
    • /
    • 1997
  • Background : Malnutrition is a common finding in patients with chronic obstructive pulmonary disease, especially in the emphysema group. Although the mechanism of malnutrition is not confirmed, it is believed to be a relative deficiency caused by hypermetabolism due to increased energy requirements of the respiratory muscles, rather than a dietary deficiency. Malnutrition in chronic obstructive pulmonary disease is not a merely coincidental finding. It is known that the nutritional status correlates with physiologic parameters including pulmonary function, muscular power, and exercise performance, and is one of the important and independent prognostic factors of the disease. Methods : Patients with chronic obstructive pulmonary disease Yongdong Severance Hospital from May, 1995 to March, 1996 and age-matched healthy control group were studied. Survey of nutritional intake, anthropometric measurements and biochemical tests were done to assess nutritional status. Relationship between nutritional status and FEV1 (forced expiratory volume at one second), which was a significant functional parameter, was assessed. Results : 1) The patient group was consisted of 25 males with mean age of 66.1years and FEV1 of $42{\pm}14%$ of predicted values. The control group was consisted of 26 healthy males with normal pulmonary function, whose mean age was 65.0 years. 2) The ratio of calorie intake/calorie requirement per day was $107{\pm}28%$ in the patient group, and $94{\pm}14%$ in the control group, showing a tendency of more nutritional intake in patient group(B=0.06). 3) There were significant differences between the patient group and control group in percent ideal body weight(92.8% vs 101.6%, p=0.024), body mass index($20.0kg/m^2$ VS $21.9kg/m^2$, p=0.015), and handgrip strength(29.0kg vs 34.3kg, p=0.003). However, there were no significant differences in triceps skinfold thickness, mid-arm muscle circumference, albumin, and total lymphocyte count between two groups. Percentage of underweight population was 40%(10/25) in the patient group, and 15%(4/26) in the control group. 4) The percent ideal body weight, triceps skinfold thickness, and mid-arm muscle circumference had significant correlation with FEV1. Conclusion : The patients with chronic obstructive pulmonary disease showed significant depletion in nutritional parameters such as body weight and peripheral muscle strength, while absolute amount of dietary intake was not insufficient. Nutritional parameters were well correlated with FEV1.

  • PDF

Study on the production of porous CuO/MnO2 using the mix proportioning method and their properties (반응몰비에 따른 다공성 CuO/MnO2의 제조 및 특성 연구)

  • Kim, W.G.;Woo, D.S.;Cho, N.J.;Kim, Y.O.;Lee, H.S.
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.182-186
    • /
    • 2015
  • In this study, the porous CuO/MnO2 catalyst was prepared through the co-precipitation process from an aqueous solution of potassium permanganate (KMnO4), manganese(II) acetate (Mn(CH3COO)2·4H2O) and copper(II) acetate (Cu(CH3COO)2·H2O). The phase change in MnO2 was analyzed according to the reaction molar ratio of KMnO4 to Mn(CH3COO)2. The reaction mole ratio of KMnO4 to Mn(CH3COO)2·4H2O was varied at 0.3:1, 0.6:1, and 1:1. The aqueous solution of Cu(CH3COO)2 was injected into a mixed solution of KMnO4 and Mn(CH3COO)2 to 10~75 wt% relative to MnO2. The Cu ion co-precipitates as CuO with MnO2 in a highly dispersed state on MnO2. The physicochemical property of the prepared CuO/MnO2 was analyzed by using the TGA, DSC, XRD, SEM, and BET. The different phase types of MnO2 were prepared according to the reaction mole ratio of KMnO4 to Mn(CH3COO)2·4H2O. The results confirmed that the porous CuO/MnO2 catalyst with γ-phase MnO2 was produced in the reaction mole ratio of KMnO4 to Mn(CH3COO)2 as 0.6:1 at room temperature.