• Title/Summary/Keyword: Relative Uncertainty

Search Result 289, Processing Time 0.028 seconds

Robust output feedback control of LTI system using estimated output derivatives (출력 미분값의 추정에 의한 선형 시불변 시스템의 로버스트 출력 궤환 제어)

  • Lee, Gun-Bok
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.273-282
    • /
    • 1996
  • This work is conceded with the estimation of output derivatives and their use for the design of robust controller for linear systems with system uncertainties due to modeling errors and disturbances. It is assumed that a nominal transfer function model and quantitative bounds for system uncertainties and known. The developed control schemes are shown to achieve regulation of the system output and ensures boundedness of the system states without imposing any structural conditions on system uncertainties and disturbances. Output derivative estimation is first conducted through restructuring of the plant in a specific parameterization. They are utilized for constructing robust nonlinear high-gain feedback controller of a SMC(Sliding Mode Control)type. The performances of the developed controller are evaluated and shown to be effective and useful through simulation study.

  • PDF

Fuzzy Linguistic Variable Based Approach for Safety Assessment of Human Body in ELF Electromagnetic Field Considering Power System States (계통상태를 고려한 ELF 전자계의 인체안전평가를 위한 퍼지언어변수 접근법)

  • 김상철;김두현;고은영
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.70-79
    • /
    • 1997
  • This paper presents a study on the fuzzy linguistic variable based approach for safety assessment of human body in ELF electromagnetic field considering power system states. To cope with the demand in modern industry, the power system becomes larger in scale, higher in voltage. The advent of high voltage system has increased the relative importance of field effects. The analysis of ELF electromagnetic field based on Quasi-Static Method is introduced while the power system is included to model the expected and/or unexpected uncertainty caused by the load fluctuation and parameter changes. In order to analyze the power system, Monte Carlo simulation method and contingency analysis method are adopted in normal state and alert state, respectively. In the safety assessment of human body, the approach based on fuzzy linguistic variable is employed to overcome the shortcomings resulting from a crisp set concept. The suggested scheme is applied to a sample system(modified IEEE 14 bus system) to validate the usefulness.

  • PDF

Evaluating the Importance of Certification Criteria for Call Center Services (콜센터 서비스인증 심사기준의 중요도 평가)

  • Lee, Mi-na;So, Soon-Hu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.139-141
    • /
    • 2016
  • With the introduction of national standards (KS) for call centers, customers are expected to have access to better-quality services in the future. The purpose of this study is to evaluate the relative importance of certification criteria for call center services using the Fuzzy AHP(Analytic Hierarchy Process) approach. Fuzzy AHP is the combination of the fuzzy set theory and AHP to deal with the uncertainty or ambiguousness of the decision-making process. The evaluation method proposed in this study can be applied to the KS services certification promoted by government.

  • PDF

The μ-synthesis and analysis of water level control in steam generators

  • Salehi, Ahmad;Kazemi, Mohammad Hosein;Safarzadeh, Omid
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.163-169
    • /
    • 2019
  • The robust controller synthesis and analysis of the water level process in the U-tube system generator (UTSG) is addressed in this paper. The parameter uncertainties of the steam generator (SG) are modeled as multiplicative perturbations which are normalized by designing suitable weighting functions. The relative errors of the nominal SG model with respect to the other operating power level models are employed to specify the weighting functions for normalizing the plant uncertainties. Then, a robust controller is designed based on ${\mu}$-synthesis and D-K iteration, and its stability robustness is verified over the whole range of power operations. A gain-scheduled controller with $H_{\infty}$-synthesis is also designed to compare its robustness with the proposed controller. The stability analysis is accomplished and compared with the previous QFT design. The ${\mu}$-analysis of the system shows that the proposed controller has a favorable stability robustness for the whole range of operating power conditions. The proposed controller response is simulated against the power level deviation in start-up and shutdown stages and compared with the other concerning controllers.

Development of analysis program for direct containment heating

  • Jiang, Herui;Shen, Geyu;Meng, Zhaoming;Li, Wenzhe;Yan, Ruihao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3130-3139
    • /
    • 2022
  • Direct containment heating (DCH) is one of the potential factors leading to early containment failure. DCH is closely related to safety analysis and containment performance evaluation of nuclear power plants. In this study, a DCH prediction program was developed to analyze the DCH loads of containment vessel. The phenomenological model of debris dispersal, metal oxidation reaction, debris-atmospheric heat transfer and hydrogen jet burn was established. Code assessment was performed by comparing with several separate effect tests and integral effect tests. The comparison between the predicted results and experimental data shows that the program can predict the key parameters such as peak pressure, temperature, and hydrogen production in containment well, and for most comparisons the relative errors can be maintained within 20%. Among them, the prediction uncertainty of hydrogen production is slightly larger. The analysis shows that the main sources of the error are the difference of time scale and the oxidation of cavity debris.

National Culture and Relational Selling: Antecedents, Outcomes and Boundary Conditions of ASB and Customer-Oriented Selling in Korea

  • Park, Jeong Eun;Deitz, George D.
    • Asia Marketing Journal
    • /
    • v.18 no.1
    • /
    • pp.75-97
    • /
    • 2016
  • Globalization and the emergence of new markets has placed increased emphasis on cross-cultural sales and marketing research. Despite considerable advances in the personal selling literature, little is known about the cross-cultural transferability of key constructs. Given the degree to which well-accepted relational sales behaviors such as ASB and customer oriented selling reflect Western values such as individualism and low uncertainty avoidance, the relative efficacy of such practices in alternative cultural context is less clear. Using a Korean sample, our results confirm the beneficial direct effects of these relational selling practices upon performance. However, we also find strong workgroup interdependence diminishes the effects of ASB and that performance fully mediates the relationship between both sales behaviors and job satisfaction. In contrast to prior results, we find female salespeople and those newer to their position demonstrate stronger ASB.

Analyzing Characteristics of GPS Dual-frequency SPP Techniques by Introducing the L2C Signal

  • Seonghyeon Yun;Hungkyu Lee
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.2
    • /
    • pp.157-166
    • /
    • 2023
  • Several experiments were carried out to analyze the impact of the modernized Global Positioning System (GPS) L2C signal on pseudorange-based point positioning. Three dual-frequency positioning algorithms, ionosphere-free linear combination, ionospheric error estimation, and simple integration, were used, and the results were compared with those of Standard Point Positioning (SPP). An analysis was conducted to determine the characteristics of each dual-frequency positioning method, the impact of the magnitude of ionospheric error, and receiver grade. Ionosphere-free and ionospheric error estimation methods can provide improved positioning accuracy relative to SPP because they are able to significantly reduce the ionospheric error. However, this result was possible only when the ionospheric error reduction effect was greater than the disadvantage of these dual-frequency positioning algorithms such as the increment of multipath and noise, impact of uncertainty of unknown parameter estimation. The RMSE of the simple integration algorithm was larger than that of SPP, because of the remaining ionospheric error. Even though the receiver grade was different, similar results were observed.

Submillimeter continuum variability in Planck Galactic cold clumps using the JCMT-SCOPE survey

  • Park, Geumsook;Kim, Kee-Tae;Johnstone, Doug
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.48.3-48.3
    • /
    • 2019
  • In the early stages of star formation, a protostar is deeply embedded in an optically thick envelope such that it is not directly observable. Variations in the protostellar accretion rate, however, will cause luminosity changes that are reprocessed by the surrounding envelope and are observable at submillimeter wavelengths. We searched for submillimeter flux variability toward 12 Planck Galactic Cold Clumps detected by the James Clerk Maxwell Telescope (JCMT)-SCUBA-2 Continuum Observations of Pre-protostellar Evolution (SCOPE) survey. These observations were conducted at 850 ㎛ using the JCMT/SCUBA-2. Each field was observed three times over about 14 months between 2016 April and 2017 June. We applied a relative flux calibration and achieved a calibration uncertainty of ~3.6% on average. We identified 136 clumps across 12 fields and detected four sources with flux variations of ~30%. For three of these sources, the variations appear to be primarily due to large-scale contamination, leaving one plausible candidate.

  • PDF

Development of Subsurface Spatial Information Model with Cluster Analysis and Ontology Model (온톨로지와 군집분석을 이용한 지하공간 정보모델 개발)

  • Lee, Sang-Hoon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.4
    • /
    • pp.170-180
    • /
    • 2010
  • With development of the earth's subsurface space, the need for a reliable subsurface spatial model such as a cross-section, boring log is increasing. However, the ground mass was essentially uncertain. To generate model was uncertain because of the shortage of data and the absence of geotechnical interpretation standard(non-statistical uncertainty) as well as field environment variables(statistical uncertainty). Therefore, the current interpretation of the data and the generation of the model were accomplished by a highly trained experts. In this study, a geotechnical ontology model was developed using the current expert experience and knowledge, and the information content was calculated in the ontology hierarchy. After the relative distance between the information contents in the ontology model was combined with the distance between cluster centers, a cluster analysis that considered the geotechnical semantics was performed. In a comparative test of the proposed method, k-means method, and expert's interpretation, the proposed method is most similar to expert's interpretation, and can be 3D-GIS visualization through easily handling massive data. We expect that the proposed method is able to generate the more reasonable subsurface spatial information model without geotechnical experts' help.

Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes (테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구)

  • Lee, Jang-Ho;Kim, Hyeong-Dae;Kim, Jung-Bae;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.