• 제목/요약/키워드: Relationship matrix

Search Result 749, Processing Time 0.033 seconds

An Adaptive Colorimetry Analysis Method of Image using a CIS Transfer Characteristic and SGL Functions (CIS의 전달특성과 SGL 함수를 이용한 적응적인 영상의 Colorimetry 분석 기법)

  • Lee, Sung-Hak;Lee, Jong-Hyub;Sohng, Kyu-Ik
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.5
    • /
    • pp.641-650
    • /
    • 2010
  • Color image sensors (CIS) output color images through image sensors and image signal processing. Image sensors that convert light to electrical signal are divided into CMOS image sensor and CCD image sensor according to transferring method of signal charge. In general, a CIS has RGB output signals from tri-stimulus XYZ of the scene through image signal processing. This paper presents an adaptive colorimetric analysis method to obtain chromaticity and luminance using CIS under various environments. An image sensor for the use of colorimeter is characterized based on the CIE standard colorimetric observer. We use the method of least squares to derive a colorimetric characterization matrix between camera RGB output signals and CIE XYZ tristimulus values. We first survey the camera characterization in the standard environment then derive a SGL(shutter-gain-level) function which is relationship between luminance and auto exposure (AE) characteristic of CIS, and read the status of an AWB(auto white balance) function. Then we can apply CIS to measure luminance and chromaticity from camera outputs and AE resister values without any preprocessing. Camera RGB outputs, register values, and camera photoelectric characteristic are used to analyze the colorimetric results for real scenes such as chromaticity and luminance. Experimental results show that the proposed method is valid in the measuring performance. The proposed method can apply to various fields like surveillant systems of the display or security systems.

The Effect of the Transcriptional Regulation of Sp1 for TGF-β1 and CTGF Expression in Scar Formation (반흔형성 과정에서 Sp1 전사인자 조절에 의한 TGF-β1 및 CTGF의 발현)

  • Park, Dong Man;Sohn, Dae Gu;Han, Ki Hwan;Lee, Sun Young;Chae, Young Mi;Chang, Young Chae;Park, Kwan Kyu
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.39-45
    • /
    • 2006
  • This study is to examine the relationship between TGF-b1 expression and CTGF expression, and to evaluate the effect of Sp1 blockade on the expression of TGF-b1, CTGF and extracellular genes, clones of fibroblasts stably transfected with Sp1 decoy ODN. R-Sp1 decoy ODN was highly resistant to degradation by nucleases or serum, compared to the linear or phosphorothioated-Sp1 decoy ODN. Skin wounds were created on the back of 36 anesthetized rats. They were divided into four groups-the rats with normal skin, with wounded skin without decoy, with wounded skin injected with R-Sp1 decoy, and with wounded skin injected with mismatched R-Sp1 decoy, respectively. Skins were collected at 3rd, 5th, 7th, 14th day after wounding. Cellular RNA was extracted by RT-PCR analysis. TGF-${\beta}1$ and CTGF were deeply related with skin fibrosis during scar formation and it appeared that TGF-${\beta}1$ may cause the induction of CTGF expression. R-Sp1 decoy ODN inhibited TGF-${\beta}1$ and CTGF expression both in cultured fibroblasts and in the skin of rats. These results indicate that targeting Sp1 with R-type decoy efficiently blocks extracellular matrix gene expression, and suggest an important new therapeutic approach to control the scarring in normal wound healing and fibrotic disorders.

Correction for SPECT image distortion by non-circular detection orbits (비원형 궤도에서의 검출에 의한 SPECT 영상 왜곡 보정)

  • Lee, Nam-Yong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.156-162
    • /
    • 2007
  • The parallel beam SPECT system acquires projection data by using collimators in conjunction with photon detectors. The projection data of the parallel beam SPECT system is, however, blurred by the point response function of the collimator that is used to define the range of directions where photons can be detected. By increasing the number of parallel holes per unit area in collimator, one can reduce such blurring effect. This approach also, however, has the blurring problem if the distance between the object and the collimator becomes large. In this paper we consider correction methods for artifacts caused by non-circular orbit of parallel beam SPECT with many parallel holes per detector cell. To do so, we model the relationship between the object and its projection data as a linear system, and propose an iterative reconstruction method including artifacts correction. We compute the projector and the backprojector, which are required in iterative method, as a sum of convolutions with distance-dependent point response functions instead of matrix form, where those functions are analytically computed from a single function. By doing so, we dramatically reduce the computation time and memory required for the generation of the projector and the backprojector. We conducted several simulation studies to compare the performance of the proposed method with that of conventional Fourier method. The result shows that the proposed method outperforms Fourier methods objectively and subjectively.

  • PDF

Preparation and Characterization of Polymer Coated BaTiO3 and Polyimide Nanocomposite Films (고분자로 표면 코팅된 BaTiO3와 이를 이용한 폴리이미드 나노복합필름의 제조 및 특성)

  • Han, Seung San;Han, Ji Yun;Choi, Kil-Yeong;Im, Seung Soon;Kim, Yong Seok
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.527-531
    • /
    • 2006
  • We have prepared organophilic inorganic particles and polyimide (PI) nanocomposite having excellent thermal stability and high dielectric constant that can be used for electronic application such as capacitor. We have chosen barium titanate (BT), a high dielectric constantmaterial and its surface was coated with nylon 6 to improve the affinity with PI. The FT-IR and TEM studies showed that the organophilic inorganic particle (BTN) has a polymer shell with thickness of 5 nm. We have suggested that it is possible to control the thickness of coating surface and also indicated the relationship between the ratio of inside and outside radius of BTN and the weight fraction of BT. The PI nanocomposite films based on poly(amic acid) and BTN were prepared by cyclodehydration reaction. The homogeneous dispersion of BTN in PI matrix was identified by using SEM. We have investigated the effect of BTN content on the coefficient of thermal stability, integral procedural decomposition temperature (IPDT), and dielectric constant of PI nanocomposite films.

Analysis of Genetic Variation of Perilla frutescens var. crispa Germplasm Using RAPD (RAPD를 이용한 차조기(Perilla frutescens var. crispa) 유전자원의 유전적 변이 분석)

  • Kim, Hyeun-Kyeung;Cho, Young-Son;Yang, Jae-Wan;Choi, Young-Whan;Kang, Jun-Soon;Lee, Yong-Jae;Son, Beung-Gu
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.119-123
    • /
    • 2010
  • Genetic variations of Chajogi (Perilla frutescens var. crispa) germplasms were investigated by using RAPD markers. Twenty-two Perilla frutescens var. crispa lines collected from various locations were subjected to RAPD analysis using 80 primers. Among them, only 22 primers showed polymorphic bands and these 22 primers provided a total of 224 bands consisting of 127 polymorphic and 97 monomorphioc bands. The polymorphic bands were subjected to phylogenetic analysis using the UPGMA method. From UPGMA, similarity co-efficiency of 22 Chajogi lines ranged from 0.72 to 0.94. The dendrogram of 22 lines obtained through the UPGMA method resulted in two groups (one major group and one minor group). Although the two groups were roughly consistent with growth phenotypes (period of flowering, period of maturity, stem length, number of branches, number of nodes, number of flower clusters and number of ovaries) in detail, much inconsistency also was present

Hydro-mechanical Behavior of Partially Saturated Soil Slopes under Rainfall (강우시 불포화토 사면에서의 수리역학적 거동 해석에 관한 연구)

  • Kim, Jae-Hong;Im, Jae-Seong;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.11
    • /
    • pp.69-78
    • /
    • 2012
  • Conventional numerical analysis for rainfall-induced slope stability has been estimated by separating seepage and stress-strain behavior, respectively. Many researchers' models from commercial softwares and literatures define that partially saturated permeability is the only function of degree of saturation (or matrix suction) and then they do not consider hydraulic-mechanical characteristics for the analysis. However, in practice, the water flow processes in a deformable soil are influenced by soil skeleton movement and the pore water pressure changed due to seepage will lead to changes in stress and to deformation of a soil. The relationship between seepage and soil behavior causes a change of partially saturated permeability as well as saturated permeability with the lapse of time. Instability of partially saturated soil slopes due to infiltration would be analyzed from reduction of negative pore water pressure calculating the process of water flow based on predicted partially saturated permeability. Therefore, partially saturated permeability should be defined by the function of degree of saturation (or matric suction) and porosity. The paper presents the comparison between staggered and monolithic coupled analysis regarding seepage and stress deformation problems. As a result, the decrease in matric suction on soil slope from monolithic analysis is slower than that from staggered analysis.

Zooplankton Community Dynamic in Lentic Freshwater Ecosystems in the Nakdong River Basin (낙동강 유역권 내 정수생태계의 동물플랑크톤 군집 동태)

  • Kim, Seong-Ki;Hong, Dong-gyun;Kang, MeeA;Lee, Kyung-Lak;Lee, Hak Young;Joo, Gea-Jae;Choi, Jong-Yun
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.3
    • /
    • pp.410-420
    • /
    • 2015
  • In order to estimate the influence of environmental factors on zooplankton communities in lentic freshwater ecosystems, 20 reservoirs and wetlands were monitored by season in 2013. A total of 109 species of zooplankton were identified during the study period. Zooplankton assemblage showed a different distribution in its density and diversity in accordance with the seasons. In particular, the density of zooplankton (98 species and 603ind. L-1) was the most in autumn when compared to the other seasons. In order to effectively analyze zooplankton distribution that are affected by various environmental factors, a Self-Organizing Map (SOM) was used, which extracts information through competitive and adaptive properties. A total of 11 variables (8 environment factors and 3 groups of zooplankton) were patterned on to the SOM. Based on a U-matrix, four clusters were identified from the model. Among zooplankton communities, rotifer displayed a positive relationship with water temperature, and cladocerans and copepod were positively related to conductivity, chlorophyll a, and nutrient factor (i. e. TN and TP). In contrast, high dissolved oxygen appeared to have a negative effect on zooplankton distribution. Consequently, the SOM results depicted a clear pattern of zooplankton density clusters partitioned by environmental factors, which play a key role in determining the seasonal distribution of zooplankton groups in lentic freshwater ecosystem.

MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES (가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화)

  • Han, Seung-Ryul;Min, Kyung-San;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

A Comparison Study of MMP Inhibitors' and Doxorubicin's Effects on the Apoptosis of U2OS Osteosarcoma Cell Line (U2OS 골육종 세포주의 세포자멸사에서 MMP억제제와 Doxorubicin 작용의 비교연구)

  • Moon, Jeong-Seok;Yeom, Bum-Woo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.2
    • /
    • pp.88-95
    • /
    • 2007
  • Purpose: The purpose of this study was to compare the proapoptotic effects of matrix metal-loproteinase inhibitor (MMPI) and doxorubicin on wild-type p53 osteosarcoma cell line, socalled U2OS cell line. Materials and Methods: U2OS cells were treated with MMP inhibitor III (MMPI III) and doxorubicin, either respectively or simultaneously. In cells treated with doxorubicin, Fas-neutralizing antibody so called ZB4 was additionally treated to examine whether the doxorubicin played a role through the Fas/FasL pathway. Cells were analysed regarding to apoptosis and cell death by flow cytometry. Results: U2OS cells incubated with doxorubicin showed significant amount of cell death in dose-dependent manner. However, those incubated with MMPI III mostly remained viable state. In addition, there is no relationship between two drugs. Cells treated with doxorubicin and ZB4 at the same time did not show down regulation of apoptosis through inhibition of Fas/FasL pathway. Conclusion: It is important to re-examine MMP inhibitor's effect on other osteosarcoma cell line with wild-type p14 as well as wild-type p53 to evaluate its proapoptotic effect.

  • PDF

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.