• Title/Summary/Keyword: Reinforce concrete

Search Result 151, Processing Time 0.021 seconds

Studies of Dapped Ended Beams with Disturbed Regions Containing T-headed bars and Steel fibers (헤디드 바와 강섬유로 보강한 Dapped Ended Beam의 구조 실험)

  • Choi Jin Hyouk;Lee Chang Hoon;Lee Joo Ha;Yoon Young Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.39-42
    • /
    • 2005
  • This test program is to investigate the benefits of using headed bars to replace conventional stirrups and using steel fibers to reinforce in the disturbed regions in the dapped ended beam, This distribution of reinforcement was selected for aspects associated with the portion of beam section in bridge structures. The beams containing T-headed bars have a superior performance such as improved ductility, larger energy adsorption and enhanced post-peak load carrying capability. The capacity of DEB with steel fibers also show increase of ductility, shear strength, and crack.

  • PDF

The Engineering Properties of Underwater-Hardening Epoxy Mortar According to the Replacement Proportion of RCSS (급냉 제강 슬래그의 대체율에 따른 수중 경화형 에폭시 모르타르의 공학적 특성)

  • Kawg Eun-Gu;Cho Sung-Hyun;Park Sang-Hun;Bae Kee-Sun;Chang Won-Seok;Kim Jin-Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.401-404
    • /
    • 2005
  • Because the underwater structures are subjected to the deterioration according to use environment, it is necessary to repair and reinforce when the durable performance are considered in structures. Epoxy mortar in the underwater used to the repair and reinforcement for durability. Epoxy mortar in the underwater-harding maked epoxy and filler. Filler is divided aggregate and powder system. Because aggregate take a matter too seriously to supply that alternation material is used to rapidly chilled steel slag. As result of study, it is possible that rapidly chilled steel slag can be applied for replacement materials about aggregate in epoxy mortar because the strength is not different.

  • PDF

Experimental Study on the Behavior of Psudo Circular Concrete Column (원형기둥 콘크리트 구멍손실 단면적의 압축거동에 관한 축소모델 실험적 연구)

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.89-98
    • /
    • 2001
  • There have been a lot of studies about repair & strengthening of the concrete structure. But there has almost not been my study on section damage effect due to holes drilled out for installing additional facilities or equipment, such as rack on the wall of building or underground culvert system, plumbing system through the column or wall of it, after being occupied. This study is to find out how much the section loss due to holes will give loss of section strength. We cm determine if we repair or reinforce it completely or not, using strength loss from the hole. Hole size of diameter 3cm, 2cm, lcm, depth of 3cm, 5cm, 10cm, and position of each hole has been considered as variables of this study. It is concluded that section loss 30% results in 53% of strength damage.

  • PDF

The Study on the Combat Placement Availability of the Reinforce Concrete Box-type Artillery Positions (철근콘크리트조 박스형 포상의 전력화 가능성에 관한 연구)

  • Baek, Jonghyuk;Kim, Sukbong;Park, Young Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.88-89
    • /
    • 2013
  • For the purpose of launching strikes, initial survivability of self-propelled artilleries is of crucial importance despite the fact that they are mobility weapon systems. This study identifies the combat placement possibility of the reinforced concrete box-type artillery positions, which might enable the replacement of the current igloo-types, in terms of cost and protection capability. In the numerical analysis the obtained numerical values have proved that these facilities have sufficient protection capability. In addition, it could be concluded that these facilities are also cost-competitive, if more than five positions are constructed simultaneously.

  • PDF

The Study of Reinforcement through the Nonlinear Static Analysis and Inelastic Seismic Performance Evaluation in School Building (학교건물에 있어서 비탄성해석 및 비선형 정적해석을 통한 내진성능 평가에 따른 보강 연구)

  • Lee, Ho;Kwon, Young-Wook;Kim, Hong-Do
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.2
    • /
    • pp.55-63
    • /
    • 2012
  • This study is about earthquake-proof reinforcement through structural function evaluation of an school building. The purpose of this study is to comparatively analyze structure reinforcement measures in consideration of safety and usability through structural function evaluation of school buididng, to offer rational measures for earthquake-proof function and to provide help in maintaining safe structures against earthquake. For this purpose, was selected for this study as an existing school building, earthquake-proof function evaluation was conducted, and measures to reinforce earthquake-proof function was offered. As for the research method, the first and the second earthquake-proof function evaluations were conducted which is an existing reinforced concrete school building. Through the abovementioned methods, earthquake-proof function evaluation were conducted, the results were analyzed and the measure to reinforce earthquake-proof function were offered(Steel damper, Carbon plate stiffeners). The offered measure to reinforce earthquake-proof function was applied to the subject structure, and comprehensive results were derived from earthquake-proof function evaluation regarding before and after earthquake-proof function reinforcement.

An Experimental Study on the Pullout Failure Behavior of Post-installed Concrete Set Anchor (후설치 콘크리트 세트앵커의 인발파괴거동에 관한 실험적 연구)

  • Suth, Ratha;Yoo, Seung-Woon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.40-47
    • /
    • 2014
  • Recently the use of concrete post-installed set anchors has been increasing because this constructing method is flexible and easy to attach or fix structural members when we repair, reinforce, or remodel structures. Accordingly, designers and builders of Korea depend on foreign design codes since there are no exact domestic anchor design codes that they could credit. The anchor in plain concrete loaded in tensile exhibits various failure modes such as concrete breakout, splitting, steel failure, pull-out and side-face blowout, that depending on the tensile strength of the steel, the strength of concrete, embedment depth, interval, the edge distance and the presence of adjacent anchor. The objective is to investigate the effects of the variations like anchor embedment depth, interval and edge distance on pull-out fracture behavior of post-installed concrete set anchor embedded in plain concrete.

Fracture formation and fracture Volume on Vertical Load by Blasting Demolition of Model Reinforced Concrete Pillars (철근 콘크리트 기둥 발파시 수직하중에 따른 파쇄형태 및 파쇄체적)

  • Park Hoon;Song Jung-Un;Kim Seung-Kon
    • Explosives and Blasting
    • /
    • v.23 no.2
    • /
    • pp.45-56
    • /
    • 2005
  • In this study, fracture formation and fracture volume by blasting demolition of model reinforced concrete pillars were compared with various vertical load and influence of reinforced steel bar. The more vertical load increased, the more tensile cracks and vertical direction cracks produced. In vertical load of 2.0ton, tensile cracks on vertical direction were predominantly produced. Generally, the more vertical load increased, the more bending deformation of concrete steel bar decreased. As a result, vertical load was influenced fracture formation of concrete and bending deformation of reinforced steel bar. Reinforced steel bar was influenced fracture volume of concrete. According to vertical load and influence of reinforce steel bar by blasting demolition of reinforced concrete pillars, drilling and blasting pattern may be modified.

Compressive Strength and Fire Resistance Performance of High Strength Concrete with Recycled Fiber Power from Fiber-Reinforced Plastics (재활용 FRP 미분말을 혼입한 고강도 콘크리트의 압축강도 및 내화성능)

  • Lee, Seung Hee;Park, Jong Won;Yoon, Koo Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Increasing of waste FRP (fiber reinforced plastics) has caused environmental problems. Recently, the technology of making fibers from waste FRP, which can be used to reinforce the concrete, was developed and the reinforced concretes were tested to study the structural performance. The purpose of this study is to investigate the effect of the powder, obtained together with F-fiber from the waste FRP, on the compressive strength and the fire resistance performance as in the high strength concrete. Strength tests show that the use of recycled FRP powder does not reduce the compressive strength of high strength concrete if the volume fraction of FRP powder is less than 0.7%. Electric furnace test results also show that the use of recycled FRP powder may increase the fire resistance performance of high strength concrete significantly.

Comparison of Nonlinear Analysis Programs for Small-size Reinforced Concrete Buildings II (소규모 철근콘크리트 건축물을 위한 비선형해석 프로그램 비교 II)

  • Yoo, Changhwan;Kim, Taewan;Park, Hong-Gun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.229-238
    • /
    • 2015
  • For small-size reinforce-concrete buildings, Midas Gen, OpenSees, and Perform-3D, which are structural analysis programs that are most popularly used at present, were applied for nonlinear static pushover analysis, and then difference between those programs was analyzed. Example buildings were limited to 2-story frames with irregular shaped walls. Analysis result showed that there were more differences than for frames only and frames with rectangular walls, but it was not so significant. Nevertheless, the capacity curve were different in some buildings, which is attributed to shape and location of walls, and feature of the analysis program. Especially, selection of automatic or manual input in Midas Gen, or nonlinear wall elements in Perform3D can affect the capacity curve and performance of the buildings. Therefore, the program users should understand the feature of the program well, and then conduct performance assessment. The result of this study is limited to low-story buildings so that it should be noted that it is possible to get different results for mid- to high-rise buildings.

Comparison of Nonlinear Analysis Programs for Small-size Reinforced Concrete Buildings I (소규모 철근콘크리트 건축물을 위한 비선형해석 프로그램 비교 I)

  • Yoo, Changhwan;Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.219-228
    • /
    • 2015
  • For small-size reinforce-concrete buildings, Midas Gen, OpenSees, and Perform-3D, which are structural analysis programs that are most popularly used at present, were applied for nonlinear static pushover analysis, and then difference between those programs was analyzed. Example buildings were limited to 2-story frames only and frames with one or more rectangular walls. Analysis results showed that there was not much difference for frames only based on capacity curves. There were some differences for frames with rectangular walls, but it was not so significant. The global behaviors represented by the capacity curve were not so different, but the feature of each analysis program appeared when the results were analyzed in more detail. Therefore, the program users should understand the feature of the program well, and then conduct performance assessment. The result of this study is limited to low-story frames only and frames with rectangular walls so that it should be noted that it is possible to get different results for frames with non-rectangular walls or mid- to high-rise buildings.