• Title/Summary/Keyword: Refractive Index Matching Method

Search Result 14, Processing Time 0.024 seconds

Measurement of Refractive Index of Solid Medium by Critical Angle Method When Air Gap is Present

  • Lim, Hwan-Hong;Kwon, Moon-Soo;Choi, Hee-Joo;Kim, Byoung-Joo;Cha, Myoung-Sik
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.210-214
    • /
    • 2008
  • A critical angle method was used to measure the index of refraction of a solid medium when an air gap between the prism and the medium is present. The gap effect was analyzed both numerically and experimentally. Since the total internal reflection is severely disturbed by the large gap, determination of the critical angle and the resulting refractive index becomes ambiguous and inaccurate. By using an index matching fluid, we could determine the index of refraction with an uncertainty of ${\pm}2{\times}1^{-3}$ even when the gap is as large as 1 ${\mu}m$.

Experimental study of the Concentric Cylinder Flow with Various Axial Slit Wall (다양한 축방향 홈이 있는 동심원통 내부 유동에 대한 실험적 연구)

  • Lee, Sang-Hyuk;Kim, Hyoung-Bum
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.123-127
    • /
    • 2007
  • The effect of axial slit wall of outer cylinder on Taylor-Couette flow was experimentally investigated. The axial slits were azimuthally located along the inner wall of outer cylinder and the number of slits was 6, 9 and 18. The radius ratio and aspect ratio of the experimental models was 0.825 and 48, respectively. We used PIV method to measure the flow field and applied refractive index matching method to resolve the image distortion due to the complex model geometry. The results showed the effect of slit on the flow transition is increased as the number of slit increased. When the model has 6 slits, there were hardly the effect of axial slit wall and the flow transition happened at the same Reynolds number of plain smooth wall model case.

  • PDF

Experimental Study of Axial Slit Wall Effect on Taylor-Couette Flow (축방향 홈이 있는 Taylor-Couette 유동의 실험적 연구)

  • Lee, Sang-Hyuk;Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.889-894
    • /
    • 2007
  • The effect of the axial slit of outer cylinder on Taylor-Couette flow was experimentally investigated. The radius ratio and aspect ratio of the model was 0.825 and 48, respectively. The depth of slits was 5mm and total 18 slits were azimuthally located along the inner wall of outer cylinder. We used PIV method to measure the flow field and applied refractive index matching method to resolve the image distortion due to the complex model geometry. The results showed the axial slit did not affect the transition from laminar Couette flow to Taylor vortex. The effect of slit wall appeared when the Reynolds number is larger than Re=143 and the slit model shows the transition to turbulent Taylor vortex flow above Re=143.

PIV Measurement of Pulsatile Flows in 3D Curved Tubes Using Refractive Index Matching Method (3차원 곡관에서의 굴절률 일치법을 이용한 맥동 유동의 PIV 측정)

  • Hong, Hyeon Ji;Ji, Ho Seong;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.511-517
    • /
    • 2016
  • Three-dimensional models of stenosis blood vessels were prepared using a 3D printer. The models included a straight pipe with axisymmetric stenosis and a pipe that was bent $10^{\circ}$ from the center of stenosis. A refractive index matching method was utilized to measure accurate velocity fields inside the 3D tubes. Three different pulsatile flows were generated and controlled by changing the rotational speed frequency of the peristaltic pump. Unsteady velocity fields were measured by a time-resolved particle image velocimetry method. Periodic shedding of vortices occurred and moves depended on the maximum velocity region. The sizes and the positions of the vortices and symmetry are influenced by mean Reynolds number and tube geometry. In the case of the bent pipe, a recirculation zone observed at the post-stenosis could explain the possibility of blood clot formation and blood clot adhesion in view of hemodynamics.

The Vector Analysis by Point Matching Method for Semicircular Optical Waveguide (점정합법에 의한 반원형 광도파로 벡터 해석)

  • 라경태;김상덕;김종빈
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.323-326
    • /
    • 1999
  • This paper describes a point matching method that is based on an expansion of the electromagnetic field in terms of a series of Bessel and modified Bessel functions multiplied by trigonometric functions. In this method, the electric and magnetic fields inside the waveguide core are matched to those outside the core at matching points on the boundary to yield matrix equations. As an example applying this method, the paper presents the results of the computation in the form of curves of the propagation constants in a semicircular optical waveguide, be formed by annealing for reduced insertion(radiation) loss when connected to optical fiber. The propagation curves are presented in a form of refractive index independent. Also, it presents relative energy distributions between inside the core and outside the core of various modes and presents field distributions.

  • PDF

Control of Free Spectral Range of tong Period Fiber Grating by Cladding Mode Waveguide Dispersion

  • Jeong, H.;Oh, K.
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.89-96
    • /
    • 2003
  • A new method to control the free spectral range of a long period fiber grating is proposed and theoretically analyzed. As the refractive index decreases radially outward in the silica cladding due to graded doping of fluorine, waveguide dispersion in the cladding modes was modified to result in the effective indices change and subsequently the phase matching conditions for coupling with the core mode in a long period fiber grating. Enlargement of the free spectral range in a long period fiber grating was theoretically confirmed.

Three-Dimensional Approaches in Histopathological Tissue Clearing System (조직투명화 기술을 통한 3차원적 접근)

  • Lee, Tae Bok;Lee, Jaewang;Jun, Jin Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.1-17
    • /
    • 2020
  • Three-dimensional microscopic approaches in histopathology display multiplex properties that present puzzling questions for specimens as related to their comprehensive volumetric information. This information includes spatial distribution of molecules, three-dimensional co-localization, structural formation and whole data set that cannot be determined by two-dimensional section slides due to the inevitable loss of spatial information. Advancement of optical instruments such as two-photon microscopy and high performance objectives with motorized correction collars have narrowed the gap between optical theories and the actual reality of deep tissue imaging. However, the benefits gained by a prolonged working distance, two-photon laser and optimized beam alignment are inevitably diminished because of the light scattering phenomenon that is deeply related to the refractive index mismatch between each cellular component and the surrounding medium. From the first approaches with simple crude refractive index matching techniques to the recent cutting-edge integrated tissue clearing methods, an achievement of transparency without morphological denaturation and eradication of natural and fixation-induced nonspecific autofluorescence out of real signal are key factors to determine the perfection of tissue clearing and the immunofluorescent staining for high contrast images. When performing integrated laboratory workflow of tissue for processing frozen and formalin-fixed tissues, clear lipid-exchanged acrylamide-hybridized rigid imaging/immunostaining/in situ hybridization-compatible tissue hydrogel (CLARITY), an equipment-based tissue clearing method, is compatible with routine procedures in a histopathology laboratory.

Estimation of Refractive Index in MIR range from the Reflectance Measurements for IR Optics Materials (반사율 측정에 의한 적외선 광학재료의 중적외선 굴절률 추정)

  • Jin, Doo-han;Jeong, Kyung-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.411-416
    • /
    • 2020
  • An optical arrangement has been set inside a photo-spectrometer to measure the reflectance of IR optics materials in mid IR range. The optical arrangement consists of equally spaced 4 gold coated full reflecting mirrors with the incidence angle of 45°. Baseline beam intensity IB has been measured while the beam proceeds through the 4 mirrors. Reflectance of a mirror has been estimated from the IB. And the beam intensity IS with the specimen in the optical path has been measured with the 4th mirror replaced with the specimen. Reflectance of the specimen has been estimated from the value of IS/IB. Then the estimated reflectance has been put in Fresnel equation relating reflectance and refractive index(RI) to estimate the RI of the material. Measurement has been made for sapphire, germanium, magnesium fluoride, and zinc sulfide. The estimated RI of the materials are closely matching with reference data and the maximum difference less than 2% over the wavelength range 3-5㎛ for all materials tested. As an FT-IR photo-spectrometer with a broadband wavelength infrared light source is used, this method has the advantage of measuring the refractive index at multiple wavelengths in a single measurement.

Growth mechanism of anodic oxide for MCT passivation (MCT 표면보호를 위한 양극산화막 성장)

  • 정진원;왕진석
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.352-356
    • /
    • 1995
  • Native oxide layer on MCT (HgCdTe) has been grown uniformly in H$\_$2/O$\_$2/ electrolyte through anodic oxidation method. It has been determined that anodic oxidation of HgCdTe in H$\_$2/O$\_$2/ electrolyte proceeds immediately with the input of constant currents without any induction time required for anodic oxideation in KOH electrolyte. Oxide layer with the resistivity of 2*10$\^$10/.ohm.cm and the refractive index of 2.1 suggested the possibility of well matching combination layer with ZnS for MCT MIS device. XPS results indicated that the major components of oxide layer grown in H202 solution is TeO$\_$2/ with the possibility of small amounts of CdTeO$\_$3/.

  • PDF

Enhancement of Light Extraction Efficiency of GaN Light Emitting Diodes Using Nanoscale Surface Corrugation (나노크기 표면 요철을 이용한 GaN LED의 광추출효율 향상)

  • Jung, Jae-Woo;Kim, Sarah;Jeong, Jun Ho;Jeong, Jong-Ryul
    • Korean Journal of Materials Research
    • /
    • v.22 no.11
    • /
    • pp.636-641
    • /
    • 2012
  • In this study, we have investigated highly efficient nanoscale surface corrugated light emitting diodes (LEDs) for the enhancement of light extraction efficiency (LEE) of nitride semiconductor LEDs. Nanoscale indium tin oxide (ITO) surface corrugations are fabricated by using the conformal nanoimprint technique; it was possible to observe an enhancement of LEE for the ITO surface corrugated LEDs. By incorporating this novel method, we determined that the total output power of the surface corrugated LEDs were enhanced by 45.6% for patterned sapphire substrate LEDs and by 41.9% for flat c-plane substrate LEDs. The enhancement of LEE through nanoscale surface corrugations was studied using 3-dimensional Finite Different Time Domain (FDTD) calculation. From the FDTD calculations, we were able to separate the light extraction from the top and bottom sides of device. This process revealed that light extraction from the top and bottom sides of a device strongly depends on the substrate and the surface corrugation. We found that enhanced LEE could be understood through the mechanism of enhanced light transmission due to refractive index matching and the increase of light scattering from the corrugated surface. LEE calculations for the encapsulated LEDs devices also revealed that low LEE enhancement is expected after encapsulation due to the reduction of the refractive index contrast.