• Title/Summary/Keyword: Reference Standard

Search Result 2,171, Processing Time 0.037 seconds

Aging Analysis of Catenary Wires in Accordance with Temperature Changes for a Long Period of Time (장기간 온도변화에 따른 전차선로 전선류의 노후도 분석)

  • Cho, Nam-Hee;Oh, Wan-Shik;Kim, Jae-moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1590-1596
    • /
    • 2016
  • In this paper, catenary wires were analyzed aging through the experiment about a new product and a test sample in accordance with temperature changes from long-term use. In case of the contact wire, the maximum load was reduced within 7% and the tensile strength showed a reduced within 6.7% compared with a new reference standard $110mm^2$. 19 Strands of messenger wire have a little more than a standard value, but result data on tensile test were less than the reference value about stranded wire. Also parts among 49 strands of dropper was found to be smaller than the reference value and it appeared greatly increasing intensity as toward the center of the strand.

Implementation Privacy Reference Architecture for Forensic Readiness

  • Shin, Yong-Nyuo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.12 no.1
    • /
    • pp.53-59
    • /
    • 2012
  • As the Privacy Act is in force in Korea, the subject of protection responsibility is increased, and continuous efforts are made to protect privacy in overseas countries, as can be seen by standard drafts related to privacy protection. However, the reality is that a formal privacy manual or guidelines are insufficient to help cope with the rapid changes and privacy leak caused by TGIF(Twitter-Google-iPhone-Facebook) these days, and practical effects cannot be expected, even though measures are taken. This paper propose a standard format for satisfying the ISO/IEC 29101 "Privacy Reference Architecture" and shows an implementation example for equipping with forensic readiness capturing indications of the incident rapidly and coming up with an effective counter measure when privacy information is disclosed.

On The Optimal Generation Using The Loss Sensitivities Derived by Angle Reference Transposition (손실감도를 이용한 계통손실 최적화에 대하여)

  • Yang, Seong-Deog;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.59-63
    • /
    • 2005
  • In this article, we apply the standard method of Lagrange multipliers to examine the algorithm in a recent IEEE publication which calculates the optimal generation for minimizing the system loss using loss sensitivities derived by angle reference transposition, and show that the two algorithms are mathematically the same.

Standardization of Fracture Toughness Testing of Ceramics in the United States

  • Quinn, G.D.;Jenkins, M.J.;Salem, J.;Bar-On, I.
    • The Korean Journal of Ceramics
    • /
    • v.4 no.4
    • /
    • pp.311-322
    • /
    • 1998
  • American Society for Testing and Materials (ASTM) standard test method PS 070-97 has been created for measuring fracture toughness of advanced ceramics. PS 070-97 includes three test methods which use beams in bending: chevron notch (CNB), single-edged precracked beam (SEPB), and surface crack in flexure (SCF). Supporting data has been collected through several Versailles Advanced Materials and Standards round robins. This paper discusses the evolution of the standard including the rationale for the choice of the three methods and the specifications in the standard. Progress on Standard Reference material 2100 which will have certified values of fracture toughness is presented.

  • PDF

Historical Control Data from 4-week Repeated Toxicity Studies in Crj:CD (SD) Rats

  • Lee, Jung-Min;Lee, Min-Ah;Do, Hyeon-Nam;Bae, Re-Ji-Na;Lee, Mi-Ju;Kim, Myoung-Jun;Jang, Ho-Song;Park, Sun-Hee;Lee, Hye-Yeong;Kang, Jin-Seok;Kang, Jong-Koo
    • Biomedical Science Letters
    • /
    • v.18 no.3
    • /
    • pp.268-275
    • /
    • 2012
  • Reference ranges of standard experimental parameters are useful for comparisons in toxicology. The aim of this study was to collect data from 4-week repeated toxicity studies in Crl:CD (SD) rats, a strain widely used for toxicity and efficacy research, for establishing domestic reference values. Data on body weight, food consumption; urinalysis, hematological, and blood biochemical parameters; and organ weights were collected from 16 toxicity studies in 220 Crl:CD (SD) rats (110 males and 110 females). The studies had been performed at a single testing facility over the last 3 years and involved animals sourced from a single breeder. The findings were collated as means, standard deviations, percentages, and ranges. Urine volume, uterus weight, eosinophil, and basophil counts, and triglyceride, total bilirubin, and gammaglutamyl transpeptidase levels showed standard deviations of 30% or more. These historical control data would help to interpret the effects of test substances in routine toxicity and efficacy studies.

Determination of Protein Content in Pea by Near Infrared Spectroscopy

  • Lee, Jin-Hwan;Choung, Myoung-Gun
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.60-65
    • /
    • 2009
  • Near infrared reflectance spectroscopy (NIRS) was used as a rapid and non-destructive method to determine the protein content in intact and ground seeds of pea (Pisum sativum L.) germplasms grown in Korea. A total of 115 samples were scanned in the reflectance mode of a scanning monochromator at intact seed and flour condition, and the reference values for the protein content was measured by auto-Kjeldahl system. In the developed ground and intact NIRS equations for analysis of protein, the most accurate equation were obtained at 2, 8, 6, 1 math treatment conditions with standard normal variate and detrend scatter correction method and entire spectrum (400-2,500 nm) by using modified partial least squares regression (n=78). External validation (n=34) of these NIRS equations showed significant correlation between reference values and NIRS estimated values based on the standard error of prediction (SEP), $R^2$, and the ratio of standard deviation of reference data to SEP. Therefore, these ground and intact NIRS equations can be applicable and reliable for determination of protein content in pea seeds, and non-destructive NIRS method could be used as a mass analysis technique for selection of high protein pea in breeding program and for quality control in food industry.

Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis

  • Paterson, Andrew;Franco, Vittorio;Patel, Shanon;Foschi, Federico
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.183-192
    • /
    • 2020
  • Purpose: This study was performed to assess the accuracy of preoperative cone-beam computed tomography (CBCT), when justified for other reasons, in locating the apical foramen and establishing the working length. Materials and Methods: Six electronic databases were searched for studies on this subject. All studies, of any type, were included if they compared measurements of working length with preoperative CBCT to measurements using an electronic apex locator (EAL) or histological reference standard. Due to the high levels of heterogeneity, an inverse-variance random-effects model was chosen, and weighted mean differences were obtained with 95% confidence intervals and P values. Results: Nine studies were included. Compared to a histological reference standard, CBCT indicated that the apical foramen was on average 0.40 mm coronal of its histological position, with a mean absolute difference of 0.48 mm. Comparisons were also performed to an EAL reference standard, but the conclusions could not be considered robust due to high levels of heterogeneity in the results. Conclusion: A low level of evidence is produced suggesting that preoperative CBCT shows the apical foramen to be on average 0.40 mm coronal to its histological position, with a mean absolute difference of 0.48 mm.

Modified Low-Votlage CMOS Bandgap Voltage Reference with CTAT Compensation (개선된 CTAT 보상을 가지는 저전압 CMOS Bandgap Voltage Reference)

  • Kim, Jae-Bung;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.753-756
    • /
    • 2012
  • In this paper, a modified low-votlage CMOS bandgap voltage reference with CTAT compensation is presented. The proposed structure doesn't use PTAT current. The proposed structure is more simple than the existing structure and doesn't use the eighteen BJT. The modified low-votlage CMOS bandgap voltage reference with CTAT compensation has been successfully verified in a standard 0.18um CMOS process. The simulation results have confirmed that, with the minimum supply voltage of 1.25V, the output reference voltage at 549mV has a temperature coefficient of 12$ppm/^{\circ}C$ from $0^{\circ}C$ to $100^{\circ}C$.

A feasibility study on Introducing the Reference Fuel(Gasoline) for Testing Vehicles in South Korea (국내 표준연료(휘발유) 도입 필요성 검토 연구)

  • Kang, Hyungkyu;Seong, Sangrae;Song, Hoyoung;Hwang, Inha;Ha, Jonghan;Na, Byungki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.824-835
    • /
    • 2016
  • Although the number of registered cars in South Korea is above 21million and one family has about 1.07 cars, there is no national standard for automobile reference fuel in South Korea. Reference fuel is the fuel used for certificating vehicle performance, emissions and fuel economy. Now, domestic market fuels are used as reference fuel. However, the quality of domestic market fuel is constantly changing by seasonal and fuel manufacturers. It may effect vehicle performance, emissions and fuel efficiency test result. On this study, market fuel quality was monitored and reference fuel standard(draft) was set by reflecting market fuel monitoring result. Reference fuel standard(draft) was applied to GDI and MPI engine. As a result, the difference of fuel economy between fuels meeting the reference fuel standards(draft) was reduced to 1.1% while the difference of fuel economy between market fuels was 3.8%.