• Title/Summary/Keyword: Reference Point System

Search Result 627, Processing Time 0.027 seconds

Wavefront Aberration Measurement of DVD pick-up lenses with a Shack-Hartmann Sensor and a Point Source (Shack-Hartmann 파면분석기와 점광원을 이용한 DVD 픽업 렌즈의 수차 측정)

  • Kang, Dong-Won;Lee, Jin-Seok;Hahn, Jae-Won
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.3
    • /
    • pp.135-138
    • /
    • 2007
  • Using a Shack-Hartmann sensor and sub-wavelength sized pinhole point source, we develope an optical testing system that measures the wavefront error of high numerical aperture and small sized optical components. The subwavelength sized pinhole generates perfect spherical waves with large diffraction angle and this makes possible to test high numerical aperture optics. The Shack-Hartmann sensor reconstructs the wavefront and calculates the aberrations. We make a home-made reference plane wave source which generates nearly perfect plane waves and the calibration with this plane source gives the overall uncertainty of the optical testing system 0.010 $\lambda$ rms.

  • PDF

Backstepping Control of a Buck-Boost Converter in an Experimental PV-System

  • Vazquez, Jesus R.;Martin, Aranzazu D.
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1584-1592
    • /
    • 2015
  • This paper presents a nonlinear method to control a DC-DC converter and track the Maximum Power Point (MPP) of a Photovoltaic (PV) system. A backstepping controller is proposed to regulate the voltage at the input of a buck-boost converter by means of Lyapunov functions. To make the control initially faster and avoid local maximum, a regression plane is used to estimate the reference voltages that must be obtained to achieve the MPP and guarantee the maximum power extraction, modifying the conventional Perturb and Observe (P&O) method. An experimental platform has been designed to verify the validity and performance of the proposed control method. In this platform, a buck-boost converter has been built to extract the maximum power of commercial solar modules under different environmental conditions.

The Influence of Suspension Stiffness on the Gearbox Input Loads in a 3-Point Suspension Wind Turbine Drive Train (풍력발전기용 3점 지지 드라이브 트레인의 지지 강성이 기어박스 입력하중에 미치는 영향)

  • Nam, Ju Seok;Nam, Yong Yun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.514-520
    • /
    • 2015
  • The effects of suspension stiffness on the reaction load of the gearbox suspension for a three-point suspension wind turbine drive train were investigated by finite element analysis. The reaction forces of the gearbox suspension appear to increase as the gearbox suspension stiffness increases; however, the main bearing stiffness has a reverse effect on the reaction forces. The influence of the gearbox suspension stiffness is greater than that of the main bearing. Since the suspensions must provide the gearbox with proper support, it is not practical to use soft gearbox suspension for small reaction forces. It is more feasible to use stiff main bearings. As a guideline for the main bearing stiffness in the present study, we propose a relative stiffness of 100-150% of the reference.

A Suggestion of Sizing System for Clean Room Wear (무진복의 치수체계에 대한 연구)

  • 이경화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.7
    • /
    • pp.1044-1055
    • /
    • 2000
  • The purpose of this study is to suggest sizing chart for a clean room wear. 3 control dimensions(Stature, Bust girth, B.N.P.∼Wrist point length) were chosen as 3 axes of clean room wear size chart. A loss function was used to determined intervals of stature, Bust girth and B.N.P.∼Wrist point length of size chart, because the loss function introduces the concept of frequency to size chart for better customer's size satisfaction. From the size table whose intervals had been determined by a loss function. The 4 sizes individually were suggested for clean room wear size chart by sex. The 3 sizes individually were suggested for clean room head cover size chart by sex too. The suggested size chart would be considered more feasible than present size chart. Also they are suggested supply reference measurement chart relevant to clean room wear manufacturing for 13 most frequent sizes.

  • PDF

Wavefront Aberration Measurement with Shack-Hartmann Sensor and Point Source (Shack-Hartmann 파면분석기와 점광원을 이용한 광학부품의 수차 측정)

  • Lee, Jin-Seok;Kim, Hak-Young;Park, Yong-Pil;Park, No-Cheol;Hahn, Jae-Won
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.160-161
    • /
    • 2005
  • Using a Shack-Hartmann sensor, we construct an optical testing system measuring the wavefront error of small optical components. The systematic error of the sensor is compensated with a reference plane-wave system that produces almost perfect plane waves. Several types of lenses are tested using a point source that generates spherical waves emitted from a pinhole. The results of the optical testing obtained with the Shack- Hartman sensor are compared with those measured with Zygo interferometer.

  • PDF

ANN-based Maximum Power Point Tracking of PV System using Fuzzy Controller (퍼지 제어기를 이용한 PV 시스템의 ANN 기반 최대전력점 추적)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.27-32
    • /
    • 2015
  • A maximum power point tracking (MPPT) algorithm using fuzzy controller was considered. MPPT method was implemented based on the voltage and reference PV voltage value was obtained from Artificial Neural Network (ANN)-model of PV modules. Therefore, measuring only the PV module voltage is adequate for MPPT operation. Fuzzy controller is used to directly control dc-dc buck converter. The simulation results have been used to verify the effectiveness of the algorithm. The proposed method is compared with conventional PO(perturbation & observation), IC(Incremental Conductance) method. The nonlinearity and adaptiveness of fuzzy controller provided good performance under parameter variations such as solar irradiation.

Analysis of Macro-Diversity in LTE-Advanced

  • Kim, Gun-Yeob Peter;Lee, Jung-Ah C.;Hong, Sang-Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.9
    • /
    • pp.1596-1612
    • /
    • 2011
  • Coordinated Multi-Point (CoMP) transmission / reception is being studied in Long Term Evolution-Advanced (LTE-A) for future evolution of the $3^{rd}$ Generation Partnership Project (3GPP) LTE. Support of soft handover is essential for improving the performance of cell edge users. CoMP provides a natural framework for enabling soft handover in the LTE system. This paper evaluates the soft handover gain in LTE-A downlink. Mathematical analysis of signal to interference plus noise ratio (SINR) gain and the handover margins for soft handover and hard handover are derived. CoMP system model is developed and an inter-cell and intra-cell interference model is derived, taking into account the pathloss, shadowing, cell loading, and traffic activity. Reference signal received power (RSRP) is used to define the triggers and the measurements for soft handover. Our results indicate that parameter choices such as handover margin and the CoMP set size impact CoMP performance gain.

A Study on Improvement of Method for Measuring the Shield Performance of Shielding Enclosures (전자파 차폐실의 차폐효과 측정방법 개선에 관한 연구)

  • Yeon, Jae-Sung;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.350-353
    • /
    • 2009
  • The shielding enclosure is very essential device to test the electromagnetic wave power generated by various RF equipments. Some standards for the shielding enclosures were established to test them in right method. Generally, There are IEEE-STD-299 and MIL-STD-285 and NSA-65-6 of the method for measuring the effectiveness of shielding enclosures, the IEEE-STD-299 combined MIL-STD-285 and NSA-65-6 about the method for measuring shielding effectiveness(SE) about 1969 years, but, the measurement point of 299 proposal is many points(including shielding wall, seam, coner beat, shielding door, etc) and demand long time of measurement. To improve SE test method for shielding enclosures was studied and suggested to develop a proper test procedure. First, we measure reference level as frequency range and H/V polarization, secondly, measure leakage point, and finally, measure shield effect and calculate SE. Our method has a merit of the less measurement point than IEEE-STD-299, and shorten time than 299, and define representation SE of shielding enclosure effectively.

  • PDF

GAIA PARALLAX ZERO POINT FROM RR LYRAE STARS

  • Gould, Andrew;Kollmeier, Juna A.
    • Journal of The Korean Astronomical Society
    • /
    • v.50 no.1
    • /
    • pp.1-5
    • /
    • 2017
  • Like Hipparcos, Gaia is designed to give absolute parallaxes, independent of any astrophysical reference system. And indeed, Gaia's internal zero-point error for parallaxes is likely to be smaller than any individual parallax error. Nevertheless, due in part to mechanical issues of unknown origin, there are many astrophysical questions for which the parallax zero-point error ${\sigma}({\pi}_0)$ will be the fundamentally limiting constraint. These include the distance to the Large Magellanic Cloud and the Galactic Center. We show that by using the photometric parallax estimates for RR Lyrae stars (RRL) within 8kpc, via the ultra-precise infrared period-luminosity relation, one can independently determine a hyper-precise value for ${\pi}_0$. Despite their paucity relative to bright quasars, we show that RRL are competitive due to their order-of-magnitude improved parallax precision for each individual object relative to bright quasars. We show that this method is mathematically robust and well-approximated by analytic formulae over a wide range of relevant distances.

Condition assessment of steel shear walls with tapered links under various loadings

  • He, Liusheng;Kurata, Masahiro;Nakashima, Masayoshi
    • Earthquakes and Structures
    • /
    • v.9 no.4
    • /
    • pp.767-788
    • /
    • 2015
  • A steel shear wall with double-tapered links and in-plane reference was developed for assisting the assessment of the structural condition of a building after an earthquake while maintaining the original role of the wall as a passive damper device. The double-tapered link subjected to in-plane shear deformation is designed to deform torsionally after the onset of local buckling and works as an indicator of the maximum shear deformation sustained by the shear wall during an earthquake. This paper first examines the effectiveness of double-tapered links in the assessment of the structural condition under various types of loading. A design procedure using a baseline incremental two-cycle loading protocol is verified numerically and experimentally. Meanwhile, in-plane reference links are introduced to double-tapered links and greatly enhance objectivity in the inspection of notable torsional deformation with the naked eye. Finally, a double-layer system, which consists of a layer with double-tapered links and a layer with rectangular links made of low-yield-point steel, is tested to demonstrate the feasibility of realizing both structural condition assessment and enhanced energy dissipation.