• Title/Summary/Keyword: Recloser-recloser coordination

Search Result 32, Processing Time 0.041 seconds

The effective recloser and sectionalizer coordination and protection scheme in distribution system interconnected a number of distributed resources (다수의 분산형 전원이 연계된 배전계통에서 리크로저와 섹셔널라이저의 보호협조 방안)

  • Jung, Hyun-Jun;Choi, Joon-Ho;Nam, Hae-Kon;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.429-431
    • /
    • 2005
  • According to the second plan of the Korean Government about technology development, utilization and popularization of new renewable energy, the continuous growth of distributed resources are expected. Various studies about impact of distributed resource on distribution system have been already accomplished. Rut there is a few paper about recloser and sectionalizer coordination and protection scheme in distribution system interconnected a number of distributed resources. In this paper, it is dealt with that recloser and sectionalizer coordination at the cases concerned with fault position. The problems of these cases are investigated through simulation.

  • PDF

The effective recloser and sectionalizer coordination and protection scheme when distributed resource is added in distribution system interconnected distributed resource (분산형 전원이 연계된 배전계통에 분산형 전원 추가 시 리크로저와 섹셔널아이저의 보호 협조 방안)

  • Jung, Hyun-Jun;Choi, Joon-Ho;Nam, Hae-Kon;Park, Sung-Jun;Park, Jang-Hyun;Ro, Kyoung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.704-706
    • /
    • 2005
  • According to the second scheme of the Korean Government about technology development, utilization and popularization of new ${\cdot}$ renewable energy, the continuous growth of distributed resources are expected. But there is a few paper about recloser and sectionalizer coordination and protection scheme in distribution system interconnected a number of distributed resources. In this paper, it is dealt with that recloser and sectionalizer coordination at the cases concerned with position among protection devices. Adding distributed resource, the problems of each case are investigated through simulation.

  • PDF

A Study on the Comparison of Reliability for Protective Coordination of Loop Power Distributions using Communication of Circuit Breaker and Recloser (차단기와 리클로져의 통신을 이용한 루프 배전계통의 보호협조 적용시 신뢰도 비교에 관한 연구)

  • Lee, Hee-Tae;Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.133-137
    • /
    • 2011
  • The purpose of smart grid is the low $CO_2$ through expansion of renewable energy. To achieve the purpose of smart grid, typical radial power distribution system will be changed to loop power distribution system. The loop power distribution system have many advantages such as low power loss, low voltage drop, and increase of connection of renewable energy. In this paper, the algorithm for minimization of interrupted section of power distribution system is proposed through communication between circuit breaker and recloser in loop power distribution system. The proposed algorithm is proved through case studies about reliability evaluation

A study of the directional recloser and sectionalizer protective coordination at 22.9[kV] distribution system with new renewable energy generation (신재생에너지원이 연계된 22.9[kV] 배전계통의 양방향 리클로저와 섹셔널라이저 보호협조 방안)

  • Lee, Yeon-Hwa;Choi, Joon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.525-526
    • /
    • 2007
  • Recently, there has been growing interest in utilizing distributed generation (DG). However, an insertion of DG to existing distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc,. The typical protection system of the existing distribution system is designed for radial network. But penetration of DG to distribution system changes existing unidirectional power flow to bidirectional power flow. Therefore, investigation to cover whole field of distribution system must be accomplished such as changing of protection devices rating by increasing fault current, reevaluation of protective coordination. This paper presents that PSCAD/EMTDC simulations was accomplished to analyze effect of DG on the distribution protective coordination. In addition, directional recloser-sectionalizer coordination are evaluates distribution system with DG by using PSCAD/EMTDC simulation.

  • PDF

A Study on the Coordination Scheme Considering the Loss of Sensitive Load by Voltage Sag at Distribution System Interconnected Dispersed Generation (배전계통에 분산전원 연계시 전압강하에 의한 민감부하의 피해를 고려한 보호협조 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.363-365
    • /
    • 2003
  • Recently, the concern of power qualiaty problem is increasing. Especially, Voltage quality problem have been increased important problem. Electronic device was affected by voltage sag. So, sensitive load that included many electronic Device was affected by voltage sag. also, it may have economic loss. In this paper, we argue the coordination scheme considering the loss of sensitive load. The coordination device of distribution system for instaneous fault is recloser and sectionalizer, But, the fault clearing time of recloser is more than 2 seconds. So, voltage sag generates long time that affected sensitive load. HS(high speed switchgear) has fast fault clearing time(0.015s) that not affected sensitive load. Therefore, the coordination applied HS is used. The proposed schemes are proved and evaluated by a case study using PSCAD/EMTDC simulation.

  • PDF

A Study of Propriety Capacity about Protection Scheme When Distribution System Interconnected with Distributed Resources (배전계통에 분산전원 연계시 보호협조측면에서 적정용량 검토)

  • Lee Yeon-Hwa;Choi Joon-Ho;Jung Hyun-Jun;Nam Hae-Kon;Moon Chae-Joo;Park Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.520-522
    • /
    • 2006
  • According to the second scheme of the Korean Government about technology development, utilization and popularization of new renewable energy, the continuous growth of distributed resources are expected. But there is a few paper about recloser and sectionalizer coordination and protection scheme in distribution system interconnected a number of distributed resources. In this paper, it is dealt with that recloser and sectionalizer coordination at the cases concerned with position among protection devices. Adding distributed resource, the problems of each case are investigated through simulation.

  • PDF

Multi-Agent based Distribution Protection Coordination Algorithm (Multi-Agent 기반의 배전계통 보호협조 알고리즘)

  • Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.4_5
    • /
    • 2009
  • A new protection coordination algorithm in Multi-Agent based distribution automation system is proposed in this paper. Distribution network protection coordination is acted by normal state distribution operation. But, in more and more complex distribution network structure, it has a big problem that central server processed all measurement data, coordination setting and controls for operation. So, a algorithm to change coordination setting is proposed automatically in terminal devices which Recloser and OCR to include Multi-Agent concepts in distribution network.

  • PDF

Interconnection Capacity Evaluation of Distributed Resources at the Distribution Networks in View of Distribution Protection Coordination (배전계통의 보호협조측면에서 본 분산전원 연계용량 검토)

  • Choi, Joon-Ho;Ro, Kyoung-Soo;Park, Sung-Jun;Song, Kyung-Bin;Yun, Sang-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.107-116
    • /
    • 2007
  • The introduction of new renewable energy is going on increase with the second plan of the Korean Government "Technology Development, Utilization and Popularization of New Renewable Energy". In general, it is connected to the power system due to the nature of it's source characteristics but it's interconnection operation impacts on the power system planning and operation. The operation schemes of the existing power distribution system are based on the unidirectional power flow, but unidirectional power flow changes to bidirectional power flow due to the interconnection operation of new renewable energy. It degrade the existing protection coordination system and power quality of the power distribution system. Thus, the technical evaluation process of the interconnection of new renewable energy are necessary. In this paper, the characteristics of the existing automatic recloser and sectionalizer are reviewed and interconnection capacity evaluation method of the DR(distributed resources) in the existing automatic recloser-sectionalizer protective coordination system are proposed.

The Online Protective Coordination Schemes of the Distribution Systems with Distributed Generation (분산전원이 연계된 배전계통의 온라인 보호협조 방안)

  • Choi, Joon-Ho;Ro, Kyoung-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.132-141
    • /
    • 2007
  • Recently, there has been growing interest in distributed resources with high-energy efficiency due to the increasing energy consumption and environmental pollution problems. But an insertion of new distributed generation to existing power distribution systems can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc. In this paper, a new method of the fault location identification at the distribution system with distributed resources, which can be determined by the magnitude and direction of the fault current, is proposed. In addition, a new online protective coordination scheme of recloser-sectionalizer is proposed based on the proposed fault location identification method for distribution system with distributed resources.

Analysis on the Protective Coordination with the Superconducting Fault Current Limiter for the Application into the KEPCO Grid

  • Kim, Jin-Seok;Kim, Jae-Chul;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.33-39
    • /
    • 2011
  • In this paper, the protection coordination of the protection devices such as the over-current relay (OCR) and recloser (R/C) with superconducting fault current limiter (SFCL) was investigated in a KEPCO grid. The operation time and protection coordination of the protection devices were changed by the SFCL. Through the analysis for protection coordination between the SFCL and the protection devices in the KEPCO grid, the operation time was observed to depend on the impedance of the SFCL.