• Title/Summary/Keyword: Real time imaging

Search Result 541, Processing Time 0.028 seconds

An Input/Output Technology for 3-Dimensional Moving Image Processing (3차원 동영상 정보처리용 영상 입출력 기술)

  • Son, Jung-Young;Chun, You-Seek
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.1-11
    • /
    • 1998
  • One of the desired features for the realizations of high quality Information and Telecommunication services in future is "the Sensation of Reality". This will be achieved only with the visual communication based on the 3- dimensional (3-D) moving images. The main difficulties in realizing 3-D moving image communication are that there is no developed data transmission technology for the hugh amount of data involved in 3-D images and no established technologies for 3-D image recording and displaying in real time. The currently known stereoscopic imaging technologies can only present depth, no moving parallax, so they are not effective in creating the sensation of the reality without taking eye glasses. The more effective 3-D imaging technologies for achieving the sensation of reality are those based on the multiview 3-D images which provides the object image changes as the eyes move to different directions. In this paper, a multiview 3-D imaging system composed of 8 CCD cameras in a case, a RGB(Red, Green, Blue) beam projector, and a holographic screen is introduced. In this system, the 8 view images are recorded by the 8 CCD cameras and the images are transmitted to the beam projector in sequence by a signal converter. This signal converter converts each camera signal into 3 different color signals, i.e., RGB signals, combines each color signal from the 8 cameras into a serial signal train by multiplexing and drives the corresponding color channel of the beam projector to 480Hz frame rate. The beam projector projects images to the holographic screen through a LCD shutter. The LCD shutter consists of 8 LCD strips. The image of each LCD strip, created by the holographic screen, forms as sub-viewing zone. Since the ON period and sequence of the LCD strips are synchronized with those of the camera image sampling adn the beam projector image projection, the multiview 3-D moving images are viewed at the viewing zone.

  • PDF

Pancreatic Compression during Lymph Node Dissection in Laparoscopic Gastrectomy: Possible Cause of Pancreatic Leakage

  • Ida, Satoshi;Hiki, Naoki;Ishizawa, Takeaki;Kuriki, Yugo;Kamiya, Mako;Urano, Yasuteru;Nakamura, Takuro;Tsuda, Yasuo;Kano, Yosuke;Kumagai, Koshi;Nunobe, Souya;Ohashi, Manabu;Sano, Takeshi
    • Journal of Gastric Cancer
    • /
    • v.18 no.2
    • /
    • pp.134-141
    • /
    • 2018
  • Purpose: Postoperative pancreatic fistula is a serious and fatal complication of gastrectomy for gastric cancer. Blunt trauma to the parenchyma of the pancreas can result from an assistant's forceps compressing and retracting the pancreas, which in turn may result in pancreatic juice leakage. However, no published studies have focused on blunt trauma to the pancreas during laparoscopic surgery. Our aim was to investigate the relationship between compression of the pancreas and pancreatic juice leakage in a swine model. Materials and Methods: Three female pigs were used in this study. The pancreas was gently compressed dorsally for 15 minutes laparoscopically with gauze grasped with forceps. Pancreatic juice leakage was visualized by fluorescence imaging after topical administration of chymotrypsin-activatable fluorophore in real time. Amylase concentrations in ascites collected at specified times was measured. In addition, pancreatic tissue was fixed with formalin, and the histology of the compressed sites was evaluated. Results: Fluorescence imaging enabled visualization of pancreatic juice leaking into ascites around the pancreas. Median concentrations of pancreatic amylase in ascites increased from 46 U/L preoperatively to 12,509 U/L 4 hours after compression. Histological examination of tissues obtained 4 hours after compression revealed necrotic pancreatic acinar cells extending from the surface to deep within the pancreas and infiltration of inflammatory cells. Conclusions: Pancreatic compression by the assistant's forceps can contribute to pancreatic juice leakage. These findings will help to improve the procedure for lymph node dissection around the pancreas during laparoscopic gastrectomy.

Algorithm Study for Diagnosis the Breast Cancer Using LMA and FDTD (LMA와 FDTD를 이용한 유방암 진단용 알고리즘 연구)

  • Seo, Min-Gyeong;Kim, Tae-Hong;Mun, Ji-Yeon;Jeon, Soon-Ik;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1124-1131
    • /
    • 2011
  • In this paper, image reconstruction algorithm for breast cancer detection using MT(Microwave Tomography) was investigated. The breast cancer detection system under development uses 16 transmit/receive antennas. The signal waveform was a sinusoidal wave at 900 MHz. To solve the 2D inverse scattering problem, we used the 2D FDTD (Finite Difference Time Domain) method for forward calculation and LMA(Levenberg-Marquardt Algorithm) for optimization. The result of the image reconstruction using the numerical phantom by MRI(Magnetic Resonance Imaging) obtained from real patient of breast cancer showed that we can detect the position of the tumor accurately.

A Study on the Interferometer Configuration for Improvement of Signal-to-Noise Ratio of Optical Coherence Tomography System (OCT 시스템의 SNR 향상을 위한 간섭계 개선에 관한 연구)

  • Yang, Sung-Kuk;Park, Yang-Ha;Chang, Won-Suk;Oh, Sang-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.126-131
    • /
    • 2004
  • As a noninvasive imaging method, optical coherence tomography system has been extensively studied because it has some advantages such as imaging of high resolution, low cost, and compact size configuration. In order to improve the SNR of OCT system, two types of interferometers were configured and then, we compared simulation with measurement of reference sample. In the OCT system is configured with Michelson interferometer, the contrast of cross-sectional image is reduced with low SNR detection which is due to loss of feedback interference signal from light source part. Also, in order to image measured data with real time, image processing program is constructed. From results of simulation, it is confirmed that improved Michelson interferometer is improved about 10[dB] with a 50 : 50 fiber coupler. And from the measurement of reference sample, about 5[dB] is improved with a 50 : 50 fiber coupler. It is confirmed that the OCT system is configured with the improved Michelson interferometer which has a good distinctive cross-sectional image due to higher contrast.

Fourier Domain Optical Coherence Tomography for Retinal Imaging with 800-nm Swept Source: Real-time Resampling in k-domain

  • Lee, Sang-Won;Song, Hyun-Woo;Kim, Bong-Kyu;Jung, Moon-Youn;Kim, Seung-Hwan;Cho, Jae-Du;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2011
  • In this study, we demonstrated Fourier-domain/swept-source optical coherence tomography (FD/SS-OCT) at a center wavelength of 800 nm for in vivo human retinal imaging. A wavelength-swept source was constructed with a semiconductor optical amplifier, a fiber Fabry-Perot tunable filter, isolators, and a fiber coupler in a ring cavity. Our swept source produced a laser output with a tuning range of 42 nm (779 to 821 nm) and an average power of 3.9 mW. The wavelength-swept speed in this configuration with bidirectionality is 2,000 axial scans per second. In addition, we suggested a modified zero-crossing method to achieve equal sample spacing in the wavenumber (k) domain and to increase the image depth range. FD/SS-OCT has a sensitivity of ~89.7 dB and an axial resolution of 10.4 ${\mu}m$ in air. When a retinal image with 2,000 A-lines/frame is obtained, an acquisition speed of 2.0 fps is achieved.

Real-Time Digital Auto-Focusing Using A-Priori Estimated Point Spread Functions (점 확산 함수 데이터베이스를 이용한 실시간 디지털 자동초점)

  • Yoo Yoon-Jong;Lee Jung-Soo;Shin Jeong-Ho;Paik Joon-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.5 s.311
    • /
    • pp.1-11
    • /
    • 2006
  • This paper presents a digital auto-focusing method using a priori estimated point-spread-functions (PSF) database. The proposed algorithm efficiently removes out-of-focus blur in a degraded input image by selecting the optimal PSF from the database. The database consists of optical characteristics of image formation system. The PSF selection Process is performed based on a novel focusing measure. The proposed method includes a spatially adaptive filter for removing both noise and ringing artifacts. Experimental results show that the proposed method efficiently removes out-of-focus blur using significantly reduced computational load compared with the existing method.

An Efficient Shaking Correction Techniques for Image Stabilization of Moving Vehicles (이동차량 영상 안정화를 위한 효율적인 흔들림 보정 기법)

  • Hong, Sung-Il;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.155-162
    • /
    • 2014
  • In this paper, we propose an efficient shaking correction techniques for a moving vehicle image stabilization. The proposed shaking correction techniques was calculated cumulative histogram for the conversion and the separating information via color separation of video image frame of the input received. And it were to matching the histogram for match the color information as compensation result of the shaking vehicle video imaging. In this paper, the proposed the shaking correction techniques was obtained to the restoration result when compared to the existing shaking correction techniques that the smallest noise and better the naturalness of image through stabilization of luminance level and color level. Also, the imaging stabilization method was demonstrated the efficiency compared to other methods through to the real-time processing without the use of the memory.

A Study on QA for Radiation Therapy Machine by Using Implemented Electronic Portal Imaging Device (전자포탈영상장치의 제작과 방사선치료장치의 QA 적용에 관한 연구)

  • Lee, Dong-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.6 s.312
    • /
    • pp.68-75
    • /
    • 2006
  • During cancer therapy by using high energy radiation, it is possible to improve the radiation therapy efficiency by performing a precise radiation therapy after verification of generated setup errors. In this paper, the video based electronic portal imaging device (EPID) which could display the portal image with near real time was developed to verify treatment position errors in radiation therapy instead of an analog typed portal film. This EPID system for applying QA tool of radiation therapy machine was consisted of a metal/fluorescent screen, $45^{\circ}$mirror, camera and image grabber. Radiation field verification has been performed to check quality assurance of the treatment machine itself by using this EPID system. The radiation field error was easily observed by edge detection of irradiated field size on EPID image when $0.6^{\circ}$ shift of collimator angle was generated. So, this implemented EPID system could be used as a radiation QA tool.

Improvement of Two-Dimensional Terahertz Image by Digital Image Processing (데이터 처리를 통한 테라헤르츠 (THz) 파의 2차원 이미지 개선)

  • Shon, Chae-Hwa;Jin, Yun-Sik;Jeon, Seuk-Gy;Kim, Keun-Ju;Jung, Sun-Shin;Yong, Chong-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.500-507
    • /
    • 2005
  • Two-dimensional (2D) images that are produced by terahertz (THz) irradiation we presented. It is possible to obtain 2D image of various materials by observing the amplitude and the phase of the THz signals which go through them. Better images are produced by combining the amplitude and phase of the signal rather than using only one of these. Homomorphic filtering that is one elf the well-known technique of digital image signal processing is effective to reduce the noise signal and can provide better quality images. The results can be applied to real-time imaging afterwards.

Prolotherapy for the Upper Extremity (상지에서의 증식치료)

  • Shin, Keun Man
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.117-121
    • /
    • 2008
  • Prolotherapy can be defined as the injection of growth factors or growth factor production stimulants to grow normal cells or tissue. Even though it has been a controversal procedure for decades, it is currently gaining in popularity among many physicians. The term prolotherapy was coined by Hacket in the 1950s to imply proliferation of normal tissue at ligamentous and tendinous entheses. The procedure has been described by other terms, such as sclerotherapy, regenerative injection therapy, and stimulated ligament repair. Incomplete healing from sprains or strains is common and can lead to chronic pain, joint instability and laxity, and is a risk factor for the development of osteoarthritis. Prolotherapy is commonly used for these musculoskeletal conditions which are refractory to usual care therapies. The proliferant solution and technique varies according to physicial training and preferance. Commonly reported proliferants include 10% to 25% dextrose, P2G and sodium morrhuate. High resolution ultrasound imaging of musculoskeletal tissue is increasing in popularity because of patient tolerability, low cost, ability to visualize tissue in real time motion and superior resolution of highly organized tissue such as a tendon. This procedure can be introduced by ultrasound imaging and tissue growth and repair after this procedure in a tendon or a ligament can be documented with ultrasound.

  • PDF