• Title/Summary/Keyword: Reactive power component current

Search Result 42, Processing Time 0.024 seconds

A Characteristic Study on the Power Factor Correction Application for Induction Motor (유도전동기에 대한 역률 보상설비의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.25-31
    • /
    • 2008
  • The field of induction motor is magnetized and demagnetized for each reversal of the current. This field component of the motor accounts for most of the reactive component of inductive load. Reactive power needs to sustain the electromagnetic field required for the induction motor to operate. Power factor of induction motor is usually low and power factor correction needs. Power factor becomes low by the effect of the reduction operation of load capacity. In most cases, Capacitor capacity for the power factor correction should be complied with the recommendation by the motor capacity. But Capacitor value for power factor correction can't change during the normal operation. In this paper, we analyzed characteristics of power and power factor changing by load fluctuation of low-voltage small size induction motor and show that lower power factor correction's parameter of existing recommendation should be revised by new value.

The Modeling of Power conversion system with PEM fuel cell (연료전지를 이용한 전력변환장치 시스템 모델링)

  • Han, Kyung-He;Kwon, Sam-Yung;Park, Hyun-June;Lee, Byung-Song;Baek, Soo-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1984-1989
    • /
    • 2008
  • A powered system with fuel cell is regarded as a high current and low voltage source. Effects of the loads on the electrical power source are important to optimize the integrated power system. The design parameters of the system should be chosen by taking into account the characteristics of the fuel cell, so the costs of the power system at given operating conditions can be reduced. Furthermore, the dynamics characteristic of the system is crucial to acquire performance in applications, particularly interactions between loads and the fuel cell system. Currently, no integrated simulation has been approached to analyze interrelated effects. Therefore, the dynamic models of power conversion system with a PEM fuel cell that includes the PEM fuel cell stack, DC/DC converter and associated controls is developed. Electric lads for the system are derived by using a power theory that separates a load current into active, reactive, distortion or a mixed current component. Dependency of the DC capacitor on the loads are analyzed.

  • PDF

Analysis of Reactive Elements on The Voltage Source PWM Converter (전압형 PWM 컨버터의 무효성분 해석)

  • Kim, Je-Hong;Jung, Hwan-Myung;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.243-245
    • /
    • 1994
  • A PWM forced-commutated converter with DC voltage source is studied in this paper. This PWM-VSC using spacs vector modulation permits to control bi-directional power exchange between the AC mains and the DC source. The principle of the active and reactive power control is presented. In transient operation, the analysis of reactive component current is performed. Finally, the simulation results are also presented and discussed.

  • PDF

Compensation of Unbalanced PCC Voltage in an Off-shore Wind Farm of PMSG Type Turbines (해상풍력단지에서의 PMSG 풍력발전기를 활용한 계통연계점 불평형 전원 보상)

  • Kang, Ja-Yoon;Han, Dae-Su;Suh, Yong-Sug;Jung, Byoung-Chang;Kim, Jeong-Joong;Park, Jong-Hyung;Choi, Young-Joon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • This paper proposes a control algorithm for permanent magnet synchronous generators with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage off-shore wind power system under unbalanced grid conditions. Specifically, the proposed control algorithm compensates for unbalanced grid voltage at the PCC (Point of Common Coupling) in a collector bus of an off-shore wind power system. This control algorithm has been formulated based on symmetrical components in positive and negative synchronous rotating reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power is described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of AC input current is injected into the PCC in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm enables the provision of balanced voltage at the PCC resulting in the high quality generated power from off-shore wind power systems under unbalanced network conditions.

A Study on the Reduction of harmonics by Current type PWM - Inverter (전류형 PWM 인버터에 의한 고조파 저감에 관한 연구)

  • Lee, Kye-Ho;Jang, Young-Hak;Yang, Seung-Hak;Jung, Young-Gook
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.359-361
    • /
    • 1987
  • It is known that the reactive component of AC power in the Power system gives no energy to outside and causes enlargement of power apparatus, voltage fluctuation and unstability of power system. The power conversion system and control system which are composed of power semiconductor devices such as Thyrisor, transistor, GTO and so on have been appeared as new sources of Harmonics. So the reduction of harmonics in power semiconductor system is one of impending problems on the point of energy conservation and improvement of power factor. This paper treates the fundamental review of the harmonics reduction by Current type PWM-Inverter. This Inverter-detects not only the fundamental wave but also that of all harmonics created in the power semiconductor system and is scheduled to control by sampled value.

  • PDF

Enhancement of Cell Voltage Balancing Control by Zero Sequence Current Injection in a Cascaded H-Bridge STATCOM (STATCOM에서 영상분 전류주입에 의한 셀간 전압평형화 제어의 향상)

  • Kwon, Byung-Ki;Jung, Seung-Ki;Kim, Tae-Hyeong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.321-329
    • /
    • 2015
  • The static synchronous compensator (STATCOM) of cascaded H-bridge configuration accompanying multiple separate DC sides is inherently subject to the problem of uneven DC voltages. These DC voltages in one leg can be controlled by adjusting the AC-side output voltage of each cell inverter, which is proportional to the active power. However, when the phase current is extremely small, large AC-side voltage is required to generate the active power to balance the cell voltages. In this study, an alternative zero-sequence current injection method is proposed, which facilitates effective cell balancing controllers at no load, and has no effect on the power grid because the injected zero sequence current only flows within the STATCOM delta circuit. The performance of the proposed method is verified through simulation and experiments.

The Control of Parallel Operation for Static UPSs (Static UPS 병렬운전 제어)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2048-2050
    • /
    • 1998
  • An uninterruptible power supply(UPS) with parallel operation is used to increase the power capacity of the system or to secure higher reliability at critical loads. In the parallel operating system composed of the multiple UPSs, load-sharing, i.e. current balance control between them is key technique. Because of its low impedance and quick response characteristics, inverter output current changes very rapidly and thereby easily researches an overload condition. The difference between total load current divided by number of operating inverters and its own current is detected as unbalanced current. Then frequency and voltage are controlled to minimize the active component and the reactive component. A good performance of the proposed load-sharing technique is verified by experiments in the parallel operating system with two 40kVA UPSs.

  • PDF

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

Compensation of Unbalanced PCC Voltage in Off-shore Wind Farms of PMSG Type Turbine

  • Kang, Jayoon;Han, Daesu;Suh, Yongsug;Jung, Byoungchang;Kim, Jeongjoong;Park, Jonghyung;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.215-216
    • /
    • 2014
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

The Modeling of Power System with PEM fuel cell (연료전지 전력 시스템의 모델링)

  • Han, K.H.;Lee, H.J.;Lee, N.Y.;Jang, H.Y.;Lee, B.Y.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.239-241
    • /
    • 2008
  • A powered system with fuel cell is regarded as a high current and low voltage source. Effects of the loads on the electrical power source are important to optimize the integrated power system. The design parameters of the system should be chosen by taking into account the characteristics of the fuel cell, so the costs of the power system at given operating conditions can be reduced. Furthermore, the dynamics characteristic of the system is crucial to acquire performance in applications, particularly interactions between loads and the fuel cell system. Currently, no integrated simulation has been approached to analyze interrelated effects. Therefore, the dynamic models of power conversion system with a PEM fuel cell that includes the PEM fuel cell stack, DC/DC converter and associated controls is developed. Electric lads for the system are derived by using a power theory that separates a load current into active, reactive, distortion or a mixed current component. Dependency of the DC capacitor on the loads are analyzed.

  • PDF