• 제목/요약/키워드: Reactive power component current

검색결과 42건 처리시간 0.024초

Comparison of Two Reactive Power Definitions in DFIG Wind Power System under Grid Unbalanced Condition

  • Ha, Daesu;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.213-214
    • /
    • 2014
  • This paper compares two instantaneous reactive power definitions in DFIG wind turbine with a back-to-back three-level neutral-point clamped voltage source converter under unbalanced grid conditions. In general, conventional definition of instantaneous reactive power is obtained by taking an imaginary component of complex power. The other definition of instantaneous reactive power can be developed based on a set of voltages lagging the grid input voltages by 90 degree. A complex quantity referred as a quadrature complex power is defined. Proposed definition of instantaneous reactive power is derived by taking a real component of quadrature complex power. The characteristics of two instantaneous reactive power definitions are compared using the ripple-free stator active power control algorithm in DFIG. Instantaneous reactive power definition based on quadrature complex power has a simpler current reference calculation control block. Ripple of instantaneous active and reactive power has the same magnitude unlike in conventional definition under grid unbalance. Comparison results of two instantaneous reactive power definitions are verified through simulation.

  • PDF

능동전력필터를 위한 확장된 전류 동기 검출 알고리즘 (Algorithm of Extended Current Synchronous Detection for Active Power Filters)

  • 정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.111-114
    • /
    • 2000
  • Harmonics and fundamental reactive power of nonlinear loads in serious unbalanced power condition are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system, but the CSD theory is not suitable any more in case of controlled independently harmonics and reactive component. Therefore a new algorithm the extended current synchronous detection (ECSD)theory for a three phase active power filter based on decomposition of fundamental reactive distorted components is proposed in this paper. The proposed ECSD theory is simulated and tested comparison with a few power theories under asymmtrical condition in power system.

  • PDF

Real Time Implementation of Active Power Filters for Harmonic Suppression and Reactive Power Compensation using dSPACE DS1104

  • Kumar, Seethapathy;Umamaheswari, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.373-378
    • /
    • 2008
  • In this paper, an Active Power Filter (APF) is implemented using a dSPACE DS1104 processor to compensate harmonics and reactive power produced by nonlinear load. The reference source current is computed based on the measurement of harmonics in the supply voltage and load current. A hysteresis based current controller has been implemented in a DSP processor for injecting the compensating current into the power system, so that APF allows suppression of the harmonics and reactive power component of load current, resulting in a supply current that is purely sinusoidal. Simulation and experimental results of the proposed APF to meet the IEEE-519 standards are presented.

무효전력 제어를 통한 새로운 독립운전 검출법 (A Novel Method for Anti-Islanding Using Reactive Power Control)

  • 정진범;최봉주;안강순;김희준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권4호
    • /
    • pp.208-216
    • /
    • 2005
  • Recently, the study of islanding phenomenon, maintains its operation even when the utility grid is removed has lead to the trend of utility interactive inverters in photovoltaic generation systems. In this paper, a novel Anti-islanding method is presented. the proposed method can keep the real average power component constant by MPPT control and cause the load current frequency with only change of reactive power component under the islanding condition. its periodical change of Reactive power component can decrease the NDZ(Non-Detective zone) so that the detection of various loads will be possible. the insufficient effect if additional reactive power component to the grid is proved theoretically and the islanding detection is also confirmed from a experimental result with a inverter for 3kW photovoltaic generation system applied the proposed Anti-islanding method.

An ANN Controlled Three-Phase Auto-Tuned Passive Filter for Harmonic and Reactive Power Compensation

  • Sindhu, M.R.;Nair, Manjula;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.403-409
    • /
    • 2009
  • Automatically tuned passive filters can improve power quality to a great extent in power systems. A novel three-phase shunt auto-tuned filter is designed to effectively compensate source current harmonics and to provide reactive power required by the non-linear load, which draws a highly reactive, harmonic-rich current from the supply. An artificial neural network (ANN) based controller selects filter component values in accordance with reactive power requirement and harmonic compensation. Traditional passive filters are permanently connected to the system and draw large amounts of source current even under light load conditions. By using auto-tuned filters, the passive filter components can be controlled according to load variations and, hence, draw only required source currents. The selection is done by the ANN with the help of a properly tuned knowledge base to provide instantaneous compensation using a digital controller.

배전선로용 단상 무효전력 보상기의 무효전력제어 (Reactive Power Control of Single-Phase Reactive Power Compensator for Distribution Line)

  • 심우식;조종민;김영록;차한주
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.73-78
    • /
    • 2020
  • In this study, a novel reactive power control scheme is proposed to supply stable reactive power to the distribution line by compensating a ripple voltage of DC link. In a single-phase system, a magnitude of second harmonic is inevitably generated in the DC link voltage, and this phenomenon is further increased when the capacity of DC link capacitor decreases. Reactive power control was performed by controlling the d-axis current in the virtual synchronous reference frame, and the voltage control for maintaining the DC link voltage was implemented through the q-axis current control. The proposed method for compensating the ripple voltage was classified into three parts, which consist of the extraction unit of DC link voltage, high pass filter (HPF), and time delay unit. HPF removes an offset component of DC link voltage extracted from integral, and a time delay unit compensates the phase leading effect due to the HPF. The compensated DC voltage is used as feedback component of voltage control loop to supply stable reactive power. The performance of the proposed algorithm was verified through simulation and experiments. At DC link capacitance of 375 uF, the magnitude of ripple voltage decreased to 8 Vpp from 74 Vpp in the voltage control loop, and the total harmonic distortion of the current was improved.

배전용 정지형 보상기의 상태관측기를 이용한 순시 유효/무효전력 보상 (Instantaneous Active/Reactive Power Compensation of Distribution Static Compensator using State Observer)

  • 김형수;최종우
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1377-1382
    • /
    • 2008
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensation current and the other part is the current control. Conventional researches use a LPF(low pass filter) to eliminate ripple component at the calculation of compensation current. But this method has a problem that LPF's characteristics restrict the compensation performance of instantaneous active and reactive power. This paper proposes a calculation of compensation current using state observer that can be a counterproposal of conventional methods using LPF. Improved performance of instantaneous active and reactive power compensation was shown by experiments.

전력용 MOSFET Inverter에 의한 무방전력보상에 관한 연구 (A Study on the Compensation of Reactive Power by Power MOSFET INVERTER)

  • 이계호;김동필
    • 대한전기학회논문지
    • /
    • 제36권3호
    • /
    • pp.163-170
    • /
    • 1987
  • It is known that reactive component of AC power in the power system gives no energy to outside and cuses enlargiment of power apparatus, voltage fluctuation and unstability of power system. The power conversion system and control system which are composed of power semiconductor devices such as tyristor, transistor, GTO and so on have been appeared as new sources of reactive power. So the cmpensation of reactive power in power semiconductor systems is one of impending problem on the point of energy conservation and inprovement of power factor. This paper treates the fundamental review of the current type power compensation system that compensates the reactive power by MOSFET inverter. This inverter detects not only the reactive power of fundamental wave but also that of all harmoics created in the power semiconductor system and is scheduled to control by sampled value.

  • PDF

디지탈 제어기에 의한 예비전원장치 (SPS)에서의 고조파 및 무효전력보상 (Harmonic and Reactive power compensation of standby power supply(SPS) using digital controller)

  • 박가우;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.498-501
    • /
    • 1994
  • This paper presents a digital calculation method of instantaneous reactive power component for standby power supply(SPS) system. Reactive current is defined in time domain, calculated instantaneously by using a TMS320C25. The theoretical analysis is verified by the digital simulation and experimental results.

  • PDF

확장된 3차원 전류 좌표계에 의한 능동전력필터의 보상성능 평가 (Compensating Performance Evaluation of Active Power Filters Using the Expanded 3-D Current Coordinates)

  • 김정근;임영철;정영국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.292-295
    • /
    • 2003
  • Conventional methods in time / frequency domain for evaluating the compensation performance of active power filters are not provided easy solutions. So, the authors have previously proposed 3-D current coordinates which is composed into active component, fundamental reactive component and distorted component of nonlinear loads current. This method has excellent performance, but can not evaluate the characteristics of nonlinear load current whether it is inductive or capacitive. Therefore, To overcome problems mentioned previously, this paper deals with the simple Average power theory and the expanded 3-D current coordinates for evaluating the compensation performance of active power filters. To confirm the validity, active power filters simulator is developed using C-language. From the simulation, results are discuss their utility.

  • PDF