• Title/Summary/Keyword: Rating Power

Search Result 514, Processing Time 0.025 seconds

Assessment of Available Transfer Capability (ATC) considering Real-time Weather Conditions (실시간 기상상태를 고려한 가용송전용량 산정)

  • Kim, Dong-Min;Bae, In-Su;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.485-491
    • /
    • 2010
  • Total Transfer Capability (TTC) should be pre-determined in order to estimate Available Transfer Capability (ATC). Typically, TTC is determined by considering three categories; voltage, stability and thermal limits. Among these, thermal limits are treated mainly in this paper on the evaluation of TTC due to the relatively short transmission line length of Korea Electric Power Corporation (KEPCO) system. This paper presents a new approach to evaluate the TTC using the Dynamic Line Rating (DLR) for the thermal limit. Since the approach includes not only traditional electrical constraints but also real-time environmental constraints, this paper obtains more cost-effective and exact results. A case study using KEPCO system confirms that the proposed method is useful for real-time operation and the planning of the electricity market.

Prediction of Dynamic Line Rating by Time Series Weather Models (시계열 기상 모델을 이용한 동적 송전 용량의 예측)

  • Kim, Dong-Min;Bae, In-Su;Kim, Jin-O;Chang, Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.35-38
    • /
    • 2005
  • This paper suggests the method that forecast Dynamic Line Rating (DLR). Thermal Overload Risk (TOR) of next time is forecasted based on current weather condition and DLR value by Monte Carlo Simulation (MCS). To model weather element of transmission line for MCS, we will propose the use of weather forecast system and statistical models that time series law is applied. Also, through case study, forecasted TOR probability confirmed can utilize by standard that decide DLR of next time. In short, proposed method may be used usefully to keep safety of transmission line and reliability of supply of electric Power by forecasting transmission capacity of next time.

  • PDF

The Study of the method of calculating Maximum voltage in Flux-Weakening Region (약계자 영역에서 최대전압 설정에 관한 연구)

  • 김장목;임익헌;류홍우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.26-30
    • /
    • 1999
  • The constraint condition is the stator voltage and the stator current to operate the motor in the flux weakening region. The maximum current is limited by the inverter current rating and the machine thermal rating. Given DC link voltage to control the motor in the flux weakening the maximum voltage is determined by considering PWM strategy, dead time, voltage drop of the inverter switching device, and the margin of the voltage for current forcing. In this paper, the new method to determine the available maximum voltage is derived by the analythic method and by considering the factors of the voltage drop. So Determining the maximum voltage is very useful to enlarge the speed operation region in the flux weakening operation, the utility of the maximum voltage is increased.

  • PDF

Magnetic Flux Saturation Analysis of Matching Transformer Considering Characteristic of Dynamic Voltage Restorer(DVR) (DVR의 특성을 고려한 매칭변압기의 자속포화 해석)

  • Shon, Jin-Geun;Kim, Dong-Joon;Kang, Min-Gu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.236-243
    • /
    • 2008
  • This paper analyses magnetic flux saturation of matching transformer considering characteristic of dynamic voltage restorer(DVR) system to solve voltage sags which are considered the dominant disturbances affecting power quality. This DVR consist of PWM inverter to inject arbitrary voltage, LC low pass filter and matching transformer for isolation and grid connection. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core of transformer. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, an advanced modeling method of magnetic flux saturation is used to analyze a magnitude and characteristic of magnetizing current. Simulation and experimental results considering characteristic of DVR system are provided to demonstrate the validity of the proposed analysis method.

Investigation of the Feasibility of a Bus-bar coupled SFCL in the 154 kV KEPCO Grid (154 kV 초전도 한류기 모선연계 적용 연구)

  • 윤용범;현옥배;황시돌;김혜림
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.291-293
    • /
    • 2003
  • Applicability and economical feasibility of a Superconducting Fault Current Limiter (SFCL) have been investigated using the PSS/E simulation for a bus bar coupling at the real 154 ㎸ KEPCO power grid near Seoul. For the investigated substation, the maximum fault current exceeds the interruption rating of 4 circuit breakers (CB) out of 9 installed in the substation. The simulation showed that a SFCL installed in the bus tie position effectively limits the fault currents to save 4 CBs, which are to be replaced by ones of gloater interruption rating, otherwise. We suggest that the optimum resistance of the SFCL be 10 Ohm for the given grid.

  • PDF

Management Approach Based on Quantitative Risk Assessment (정량적 리스크 평가를 기초로 한 경영관리)

  • Jung, Won
    • Journal of Applied Reliability
    • /
    • v.8 no.4
    • /
    • pp.167-179
    • /
    • 2008
  • System risk is the totality of all safety risks to customers, employees, suppliers, and other third parties that arise due to system operations. To assess the risk of major hazards with the potential to cause fatality to the customers and other members of the public, quantitative risk assessment methodologies are used. This paper presents the general principles of risk based management approach to improve the safety of high risk systems such as aviation, railway, and nuclear power plants. For the suitable risk control arrangement, case studies of acceptable risk level, risk rating matrix, and safety management philosophy are presented.

  • PDF

UPFC Model for Stability Study Considering the Controller Rating (UPFC 설비용량을 고려한 안정도 해석 모형)

  • Kim, H.M.;Kook, K.S.;Jeon, J.H.;Lee, Y.W.;Oh, T.K.;Jang, B.H.;Chu, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.269-272
    • /
    • 1998
  • This paper presents an UPFC(Unified Power Flow Controlled model that considered rating for stability study. The proposed UPFC model was implemented by PSS/E and IPLAN. As a control strategy for damping electromechnical oscillations, energy function method was adopted. By the adopted control law, the damping effect is robust with respect to loading condition, fault location and network structure. The effect of control of the UPFC model was demonstrated on a one machine infinite bus system.

  • PDF

The Study on Improvement of Audio Noise When 900MHz GSM Cellular Phone Built in HPC(Handheld PC) (GSM 모듈을 탑재한 HPC(Handheld PC)에서의 오디오 노이즈 개선에 관한 연구)

  • 박희봉;장복현;황금찬;박용서
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8A
    • /
    • pp.1169-1178
    • /
    • 1999
  • In this paper, the method to improve audio noise when GMS(Global System of Mobile Communication) is built in HPC(Handheld PC)is provided. The biggest problem with quality of audio is improved by connecting GSM module with wire to the widest erea near by HPC Power Ground to reduce impedance difference, and designing amplifier and earpiece, Result of measurement is satisfied with GSM Acoustic Standard. Standard of GSM Audio is declared in GSM 11.10 ETS 300 607-1. Measuring items corresponds to that standard and B&K Type 6712 is used for measurement. The list of measurement presented in this paper is Sending Sensitivity Frequency Response and SLR, Sending Loudness Rating( SLR level), Receiving Sensitivity Loudness Rating(RLR level), Talker Sidetone(STMR), Stability margin, and Echo Loss(ERL)

  • PDF

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

Investigation into Transformer Protective Relay Setting Rule Considering Error Ratio (오차를 고려한 765kV 변압기 보호 계전 정정룰 고찰)

  • Bae, Y.J.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Kim, S.T.;Choi, J.L.;Jeong, C.H.;Yoo, Y.S.;Cho, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.229-231
    • /
    • 2002
  • The digital current differential relaying scheme is widely used for primary protection of 765(kV) power transformer. The current differential relay pickup the internal fault at the threshold which is set at 30% of rating current. Margin of 30% include current transformer error 5%, relay error 5%, on load tap changer error 7% and margin factor 140% obtained from the field experience. In this paper transformer protection relay and relay setting rule of high voltage power system are discussed. And we verify the correctness of relay setting rule with current differential relay using Matlab simulation.

  • PDF