• 제목/요약/키워드: Raman Lidar

검색결과 48건 처리시간 0.02초

The Measurement of the LIDAR Ratio by Using the Rotational Raman LIDAR

  • Choi, Sung-Chul;Baik, Sung-Hoon;Park, Seung-Kyu;Cha, Hyung-Ki;Song, Im-Kang;Kim, Duk-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.174-177
    • /
    • 2010
  • The rotational Raman LIDAR technique has been used to accurately measure aerosol optical properties such as backscatter coefficient, extinction coefficient, and LIDAR ratio. In the case of the vibrational Raman technique, the ${\AA}$ngstr$\ddot{o}$om exponent, which has wavelength dependence on the particle properties, is assumed to obtain the extinction coefficient. However, this assumed ${\AA}$ngstr$\ddot{o}$m exponent can cause systematic errors in retrieving aerosol optical properties. In the case of the rotational Raman technique, the aerosol optical properties can be measured without any assumptions about the ${\AA}$ngstr$\ddot{o}$m exponent. In this paper, the LIDAR ratio was measured by using the rotational Raman LIDAR and vibrational Raman LIDAR in the troposphere. And, the LIDAR ratios measured by these two methods were compared.

라만-탄성 라이다를 이용한 황사 및 오염 에어러솔의 라이다 비 측정 연구 (Measurements of the Lidar Ratio for Asian Dust and Pollution Aerosols with a Combined Raman and Back-scatter Lidar)

  • 윤순창;이영지;김상우;김만해
    • 대기
    • /
    • 제20권4호
    • /
    • pp.483-494
    • /
    • 2010
  • The vertical profiles of the extinction coefficient, the backscatter coefficient, and the lidar ratio (i.e., extinction-to-backscattering ratio) for Asian dust and pollution aerosols are determined from Raman (inelastic) and elastic backscatter signals. The values of lidar ratios during two polluted days is found between 52 and 82 sr (July 22, 2009) and 40~60 sr (July 31, 2009) at 52 nm, with relatively low value of particle depolarization ratio (<5%) and high value of sun photometer-derived Angstrom exponent (> 1.2). However, lidar ratios between 25 and 40 sr are found during two Asian dust periods (October 20, 2009 and March 15, 2010), with 10~20% of particle depolarization ratio and the relatively low value of sun photometer-derived Angstrom exponent (< 0.39). The lidar ratio, particle depolarization ratio and color ratio are useful optical parameter to distinguish non-spherical coarse dust and spherical fine pollution aerosols. The comparison of aerosol extinction profiles determined from inelastic-backscatter signals by the Raman method and from elastic-backscatter signals by using the Fernald method with constant value of lidar ratio (50 sr) have shown that reliable aerosol extinction coefficients cannot be determined from elastic-backscatter signals alone, because the lidar ratio varies with aerosol types. A combined Raman and elastic backscatter lidar system can provide reliable information about the aerosol extinction profile and the aerosol lidar ratio.

이산화탄소 원격 계측을 위한 광 계수 방식의 라만 라이다 장치 개발 (Development of a Raman Lidar System Using the Photon-counting Method to Measure Carbon Dioxide)

  • 박선호;최인영;윤문상
    • 한국광학회지
    • /
    • 제35권2호
    • /
    • pp.71-80
    • /
    • 2024
  • 이산화탄소 원격 계측을 위한 라만 라이다 장치를 개발하기 위해 라만 라이다 장치의 소형화를 진행하고, 이에 스캐닝 장치를 결합하여 라만 라이다 시스템을 개발하였다. 개발한 시스템의 성능 검증을 위하여 가스 챔버를 약 87 m 거리에 위치시킨 후, 이산화탄소의 농도 변화에 따른 라만 산란 신호를 계측하였다. 그 결과 개발된 라만 라이다 장치를 이용하였을 때 약 0.67-40 vol% 사이의 농도에서 높은 선형성을 나타냄을 확인하였다.

라만 라이다를 이용한 대기 중 이산화탄소 혼합비 측정 (Ambient CO2 Measurement Using Raman Lidar)

  • 김대원;이한림;박준성;최원이;양지원;강형우
    • 대한원격탐사학회지
    • /
    • 제35권6_3호
    • /
    • pp.1187-1195
    • /
    • 2019
  • 우리는 처음으로 이산화탄소 지중 저장소에서 지표로 누출되는 이산화탄소를 원격으로 탐지 및 농도를 측정하는 라만 라이다 시스템을 개발하였다. 본 연구에서 개발한 라만 라이다의 송신단은 355 nm 파장에서 80 mJ의 에너지를 가진 레이저, 빔 익스펜더(Beam expender)로 구성되어 있으며 수신단은 망원경, 광학 수신기 및 검출기 등으로 구성된다. 실내 이산화탄소 셀 측정에서 라만 라이다의 이산화탄소 농도 측정 정확도는 99.89%였다. 또한, 우리는 라만 라이다의 이산화탄소 원거리 측정 능력을 평가하기 위해서 부경대학교에서 2019년 10월에 일주일간 야외 측정을 수행하였다. 이산화탄소 지점 측정 장비는 라만 라이다로 부터 300 m, 350 m 떨어진 곳에 위치하였다. 야외 측정 결과에서 라만 라이다로 측정된 이산화탄소 농도와 지점 측정 장비로 측정된 이산화탄소 농도와 좋은 상관관계를 보여준다. 라만 라이다와 지점 측정 장비로 측정된 이산화탄소 농도도 사이의 상관 계수(R), 평균 절대 오차(Mean Absolute Error; MAE), 평균 제곱근 오차(Root Mean Square Error; RMSE), 는 각각 0.67, 2.78 ppm, 3.26 ppm 이다.

광 계수 방식의 라만 라이다 시스템을 이용한 원격 수소 가스 농도 계측 방법에 대한 연구 (Study of a Method for Measuring Hydrogen Gas Concentration Using a Photon-counting Raman Lidar System)

  • 최인영;백성훈;차정호;김진호
    • 한국광학회지
    • /
    • 제30권3호
    • /
    • pp.114-119
    • /
    • 2019
  • 본 논문은 원격으로 수소 가스의 계측이 가능한 광 계수 방식의 소형 라만 라이다 시스템 개발에 관한 것이다. 수소 가스에 의한 라만 신호는 매우 미약한 신호로서, 신호 대 잡음비가 매우 낮다. 광 계수기는 광 판별기를 갖고 있어, 레이저에 의하여 발생한 배경 신호의 전기적 잡음을 제거할 수 있는 장점을 갖고 있다. 본 연구에서는 출력이 낮은 레이저와 광 계수기를 이용하여 소형의 라만 라이다 시스템을 개발하였다. 개발된 광 계수 방식의 라만 라이다 시스템의 원격 수소 가스 검출 능력을 증명하기 위하여 수소 가스 농도를 조절할 수 있는 가스 챔버를 이용하여 수소 가스 농도 측정 실험을 수행하였다. 그 결과 10 m 거리에서 최소 0.65 vol.%의 수소 가스 농도 검출이 가능하였다.

라만 라이다 시스템을 이용한 라이다 중첩함수 산출 (Retrieval of Lidar Overlap Factor using Raman Lidar System)

  • 노영민;;신동호;이경화
    • 한국대기환경학회지
    • /
    • 제25권5호
    • /
    • pp.450-458
    • /
    • 2009
  • The range-dependent overlap factor of a lidar system can be determined experimentally if a Raman backscatter signal by molecule is measured in addition to the usually observed elastic backscatter signal, which consists of a molecular component and a particle component. The direct determination of the overlap profile is presented and applied to a lidar measurement according to variation of telescope field-of-view and distance between telescope and transmitting laser. The retrieval of extinction coefficient by Raman method can generate high errors for heights below planetary boundary layer if the overlap effect is ignored. The overlap correction method presented here has been successfully applied to experimental data obtained in Gwangju, Korea.

라만 라이다의 석영 채널을 이용한 고도별 황사 농도 산출 (A Retrieval of Vertically-Resolved Asian Dust Concentration from Quartz Channel Measurements of Raman Lidar)

  • 노영민;이권호;이한림
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.326-336
    • /
    • 2011
  • The Light Detection and Ranging (Lidar) observation provides a specific knowledge of the temporal and vertical distribution and the optical properties of the aerosols. Unlike typical Mie scattering Lidars, which can measure backscattering and depolarization, the Raman Lidar can measure the quartz signal at the ultra violet (360 nm) and the visible (546 nm) wavelengths. In this work, we developed a method for estimating mineral quartz concentration immersed in Asian dust using Raman scattering of quartz (silicon dioxide, silica). During the Asian dust period of March 15, 16, and 21 in 2010, Raman lidar measurements detected the presence of quartz, and successfully showed the vertical profile of the dust concentrations. The satellite observations such as the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) confirmed spatial distribution of Asian dust. This approach will be useful for characterizing the quartz dominated in the atmospheric aerosols and the investigations of mineral dust. It will be especially applicable for distinguishing the dust and non-dust aerosols in studies on the mixing state of Asian aerosols. Additionally, the presented method combined with satellite observations is enable qualitative and quantitative monitoring for Asian dust.

수소 가스 검출용 라만 라이다 측정기의 성능 평가를 위한 기초 연구 (A Basic Study for the Performance Evaluation of a Raman LiDAR Detector for Detecting Hydrogen Gas)

  • 조원보;임윤규;김양균;박병직
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.205-211
    • /
    • 2023
  • Hydrogen gas is light and diffuses very quickly. Therefore, when a leakage accident occurs, the damage is great, so a technology that can quickly measure the leakage in the air at a long distance is needed. In order to develop hydrogen gas leaked in the atmosphere in a non-contact manner, an experiment was performed to measure hydrogen gas using a lidar technology using the Raman effect. Hydrogen Raman signals were detected using a UV LED light source, which is a Raman light source, and a spectrometer in the ultraviolet region including an optical filter in the 400-430 nm band. To develop this, a Raman lidar optical structure was designed to measure the hydrogen Raman signal at a certain distance, and the hydrogen Raman spectrum was confirmed using a standard gas to evaluate the performance of this optical structure. The linearity was found to be 0.99 using hydrogen standard gas (10, 50, 100, 500, 1,000 ppm). Accordingly, a Raman lidar capable of measuring hydrogen gas rapidly diffusing in the air in an open state was developed to improve the limitations of existing hydrogen sensors.

수증기의 연직 분포 측정을 위한 라만 라이다 장치의 개발 및 GNSS, MWR 장비와 상호 비교연구 (Development of Raman LIDAR System to Measure Vertical Water Vapor Profiles and Comparision of Raman LIDAR with GNSS and MWR Systems)

  • 박선호;김덕현;김용기;윤문상;정해두
    • 한국광학회지
    • /
    • 제22권6호
    • /
    • pp.283-290
    • /
    • 2011
  • 수증기의 혼합비를 측정하기 위하여 라만 라이다 시스템을 설계 제작하였다. 시스템을 검증하기 위하여 가강수량과 분포에 대하여 상용 마이크로파 라이오메터(MWR)와 GPS 신호를 이용하는 방법과 비교 연구를 수행하였다. GNSS 방법으로 측정한 총가강수량과 본 라이다 방법에서는 작은 차이를 보였는데, 이는 라이다 방법으로 얻을 수 있는 수증기의 측정고도가 제한적이기 때문이다. 반면에 MWR 방법과 라이다 방법으로 얻은 고도에 따른 수증기량은 수증기량이 급격하게 변하는 구름 경계나 경계고도 근처에서 심한 차이를 보이고 있었다. MWR은 그 밀도가 급격하게 변하는 곳에서 취약한 점을 보였으나 개발된 라만 라이다의 경우는 그 밀도가 급격히 변하는 곳에서도 측정이 원활하게 이루어지고 있음을 알 수 있었다.