• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.036 seconds

Ultrasonographic Features of Medullary Thyroid Carcinoma: Do they Correlate with Pre- and Post-Operative Calcitonin Levels?

  • Cho, Kyung Eun;Gweon, Hye Mi;Park, Ah Young;Yoo, Mi Ri;Kim, Jeong-Ah;Youk, Ji Hyun;Park, Young Mi;Son, Eun Ju
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3357-3362
    • /
    • 2016
  • Purpose: To correlate ultrasonographic (US) features of medullary thyroid carcinoma (MTC) with preoperative and post-operative calcitonin levels. Materials and Methods: A total of 130 thyroid nodules diagnosed as MTC were evaluated. Two radiologists retrospectively evaluated preoperative US features according to size, shape, margin, echogenicity, type of calcification, and lymph node status. Postoperative clinical and imaging follow-up (mean duration $31.9 {\pm} 22.5$ months) was performed for detection of tumor recurrence. US features, presence of LN metastasis, and tumor recurrence were compared between MTC nodules with and without elevated preoperative calcitonin (>100 pg/mL). Those with normalized and non-normalized postoperative calcitonin levels groups were also compared. Results: Common US features of MTCs were solid internal content (90.8%), irregular shape (44.6%), circumscribed margin (46.2%), and hypoechogenicity (56.2%). Comparing MTC nodules with and without elevated preoperative calcitonin levels, the size and shape of MTC nodule and lymph node metastasis showed statistical significance (p<0.05). Postoperative calcitonin normalization correlated with US features of tumor size (p=0.002), margin (p=0.034), shape ($p{\leq}0.001$), and presence of calcification (p=0.046). Tumor recurrence and LN metastasis were more prevalent in patients without normalization of postoperative calcitonin than in those with normalization (p=0.001). Conclusions: Serum calcitonin measurement is helpful for early diagnosis and predicting prognosis. Postoperative calcitonin measurement is also important for postoperative US follow up, especially in cases with larger nodule size, presence of calcification, irregular shape, and irregular margin.

Evolution of Radiological Treatment Response Assessments for Cancer Immunotherapy: From iRECIST to Radiomics and Artificial Intelligence

  • Nari Kim;Eun Sung Lee;Sang Eun Won;Mihyun Yang;Amy Junghyun Lee;Youngbin Shin;Yousun Ko;Junhee Pyo;Hyo Jung Park;Kyung Won, Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1089-1101
    • /
    • 2022
  • Immunotherapy has revolutionized and opened a new paradigm for cancer treatment. In the era of immunotherapy and molecular targeted therapy, precision medicine has gained emphasis, and an early response assessment is a key element of this approach. Treatment response assessment for immunotherapy is challenging for radiologists because of the rapid development of immunotherapeutic agents, from immune checkpoint inhibitors to chimeric antigen receptor-T cells, with which many radiologists may not be familiar, and the atypical responses to therapy, such as pseudoprogression and hyperprogression. Therefore, new response assessment methods such as immune response assessment, functional/molecular imaging biomarkers, and artificial intelligence (including radiomics and machine learning approaches) have been developed and investigated. Radiologists should be aware of recent trends in immunotherapy development and new response assessment methods.

Differences in the panoramic appearance of cleft alveolus patients with or without a cleft palate

  • Takeshi Fujii;Chiaki Kuwada;Yoshitaka Kise;Motoki Fukuda;Mizuho Mori;Masako Nishiyama;Michihito Nozawa;Munetaka Naitoh;Yoshiko Ariji;Eiichiro Ariji
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.25-31
    • /
    • 2024
  • Purpose: The purpose of this study was to clarify the panoramic image differences of cleft alveolus patients with or without a cleft palate, with emphases on the visibility of the line formed by the junction between the nasal septum and nasal floor(the upper line) and the appearances of the maxillary lateral incisor. Materials and Methods: Panoramic radiographs of 238 patients with cleft alveolus were analyzed for the visibility of the upper line, including clear, obscure or invisible, and the appearances of the maxillary lateral incisor, regarding congenital absence, incomplete growth, delayed eruption and medial inclination. Differences in the distribution ratio of these visibility and appearances were verified between the patients with and without a cleft palate using the chi-square test. Results: There was a significant difference in the visibility distribution of the upper line between the patients with and without a cleft palate (p<0.05). In most of the patients with a cleft palate, the upper line was not observed. In the unilateral cleft alveolus patients, the medial inclination of the maxillary lateral incisor was more frequently observed in patients with a cleft palate than in patients without a cleft palate. Conclusion: Two differences were identified in panoramic appearances. The first was the disappearance (invisible appearance) of the upper line in patients with a cleft palate, and the second was a change in the medial inclination on the affected side maxillary lateral incisor in unilateral cleft alveolus patients with a cleft palate.

Development and Testing of a Machine Learning Model Using 18F-Fluorodeoxyglucose PET/CT-Derived Metabolic Parameters to Classify Human Papillomavirus Status in Oropharyngeal Squamous Carcinoma

  • Changsoo Woo;Kwan Hyeong Jo;Beomseok Sohn;Kisung Park;Hojin Cho;Won Jun Kang;Jinna Kim;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.1
    • /
    • pp.51-61
    • /
    • 2023
  • Objective: To develop and test a machine learning model for classifying human papillomavirus (HPV) status of patients with oropharyngeal squamous cell carcinoma (OPSCC) using 18F-fluorodeoxyglucose (18F-FDG) PET-derived parameters in derived parameters and an appropriate combination of machine learning methods in patients with OPSCC. Materials and Methods: This retrospective study enrolled 126 patients (118 male; mean age, 60 years) with newly diagnosed, pathologically confirmed OPSCC, that underwent 18F-FDG PET-computed tomography (CT) between January 2012 and February 2020. Patients were randomly assigned to training and internal validation sets in a 7:3 ratio. An external test set of 19 patients (16 male; mean age, 65.3 years) was recruited sequentially from two other tertiary hospitals. Model 1 used only PET parameters, Model 2 used only clinical features, and Model 3 used both PET and clinical parameters. Multiple feature transforms, feature selection, oversampling, and training models are all investigated. The external test set was used to test the three models that performed best in the internal validation set. The values for area under the receiver operating characteristic curve (AUC) were compared between models. Results: In the external test set, ExtraTrees-based Model 3, which uses two PET-derived parameters and three clinical features, with a combination of MinMaxScaler, mutual information selection, and adaptive synthetic sampling approach, showed the best performance (AUC = 0.78; 95% confidence interval, 0.46-1). Model 3 outperformed Model 1 using PET parameters alone (AUC = 0.48, p = 0.047) and Model 2 using clinical parameters alone (AUC = 0.52, p = 0.142) in predicting HPV status. Conclusion: Using oversampling and mutual information selection, an ExtraTree-based HPV status classifier was developed by combining metabolic parameters derived from 18F-FDG PET/CT and clinical parameters in OPSCC, which exhibited higher performance than the models using either PET or clinical parameters alone.

Diagnosis of Unruptured Intracranial Aneurysms Using Proton-Density Magnetic Resonance Angiography: A Comparison With High-Resolution Time-of-Flight Magnetic Resonance Angiography

  • Pae Sun Suh;Seung Chai Jung;Hye Hyeon Moon;Yun Hwa Roh;Yunsun Song;Minjae Kim;Jungbok Lee;Keum Mi Choi
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.575-588
    • /
    • 2024
  • Objective: Differentiating intracranial aneurysms from normal variants using CT angiography (CTA) or MR angiography (MRA) poses significant challenges. This study aimed to evaluate the efficacy of proton-density MRA (PD-MRA) compared to high-resolution time-of-flight MRA (HR-MRA) in diagnosing aneurysms among patients with indeterminate findings on conventional CTA or MRA. Materials and Methods: In this retrospective analysis, we included patients who underwent both PD-MRA and HR-MRA from August 2020 to July 2022 to assess lesions deemed indeterminate on prior conventional CTA or MRA examinations. Three experienced neuroradiologists independently reviewed the lesions using HR-MRA and PD-MRA with reconstructed voxel sizes of 0.253 mm3 or 0.23 mm3, respectively. A neurointerventionist established the gold standard with digital subtraction angiography. We compared the performance of HR-MRA, PD-MRA (0.253-mm3 voxel), and PD-MRA (0.23-mm3 voxel) in diagnosing aneurysms, both per lesion and per patient. The Fleiss kappa statistic was used to calculate inter-reader agreement. Results: The study involved 109 patients (average age 57.4 ± 11.0 years; male:female ratio, 11:98) with 141 indeterminate lesions. Of these, 78 lesions (55.3%) in 69 patients were confirmed as aneurysms by the reference standard. PD-MRA (0.253-mm3 voxel) exhibited significantly higher per-lesion diagnostic performance compared to HR-MRA across all three readers: sensitivity ranged from 87.2%-91.0% versus 66.7%-70.5%; specificity from 93.7%-96.8% versus 58.7%-68.3%; and accuracy from 90.8%-92.9% versus 63.8%-69.5% (P ≤ 0.003). Furthermore, PD-MRA (0.253-mm3 voxel) demonstrated significantly superior per-patient specificity and accuracy compared to HR-MRA across all evaluators (P ≤ 0.013). The diagnostic accuracy of PD-MRA (0.23-mm3 voxel) surpassed that of HR-MRA and was comparable to PD-MRA (0.253-mm3 voxel). The kappa values for inter-reader agreements were significantly higher in PD-MRA (0.820-0.938) than in HR-MRA (0.447-0.510). Conclusion: PD-MRA outperformed HR-MRA in diagnostic accuracy and demonstrated almost perfect inter-reader consistency in identifying intracranial aneurysms among patients with lesions initially indeterminate on CTA or MRA.

CT-Based Fagotti Scoring System for Non-Invasive Prediction of Cytoreduction Surgery Outcome in Patients with Advanced Ovarian Cancer

  • Na Young Kim;Dae Chul Jung;Jung Yun Lee;Kyung Hwa Han;Young Taik Oh
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1481-1489
    • /
    • 2021
  • Objective: To construct a CT-based Fagotti scoring system by analyzing the correlations between laparoscopic findings and CT features in patients with advanced ovarian cancer. Materials and Methods: This retrospective cohort study included patients diagnosed with stage III/IV ovarian cancer who underwent diagnostic laparoscopy and debulking surgery between January 2010 and June 2018. Two radiologists independently reviewed preoperative CT scans and assessed ten CT features known as predictors of suboptimal cytoreduction. Correlation analysis between ten CT features and seven laparoscopic parameters based on the Fagotti scoring system was performed using Spearman's correlation. Variable selection and model construction were performed by logistic regression with the least absolute shrinkage and selection operator method using a predictive index value (PIV) ≥ 8 as an indicator of suboptimal cytoreduction. The final CT-based scoring system was internally validated using 5-fold cross-validation. Results: A total of 157 patients (median age, 56 years; range, 27-79 years) were evaluated. Among 120 (76.4%) patients with a PIV ≥ 8, 105 patients received neoadjuvant chemotherapy followed by interval debulking surgery, and the optimal cytoreduction rate was 90.5% (95 of 105). Among 37 (23.6%) patients with PIV < 8, 29 patients underwent primary debulking surgery, and the optimal cytoreduction rate was 93.1% (27 of 29). CT features showing significant correlations with PIV ≥ 8 were mesenteric involvement, gastro-transverse mesocolon-splenic space involvement, diaphragmatic involvement, and para-aortic lymphadenopathy. The area under the receiver operating curve of the final model for prediction of PIV ≥ 8 was 0.72 (95% confidence interval: 0.62-0.82). Conclusion: Central tumor burden and upper abdominal spread features on preoperative CT were identified as distinct predictive factors for high PIV on diagnostic laparoscopy. The CT-based PIV prediction model might be useful for patient stratification before cytoreduction surgery for advanced ovarian cancer.

A new bite block for panoramic radiographs of anterior edentulous patients: A technical report

  • Park, Jong-Woong;Symkhampha, Khanthaly;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Panoramic radiographs taken using conventional chin-support devices have often presented problems with positioning accuracy and reproducibility. The aim of this report was to propose a new bite block for panoramic radiographs of anterior edentulous patients that better addresses these two issues. Materials and Methods: A new panoramic radiography bite block similar to the bite block for dentulous patients was developed to enable proper positioning stability for edentulous patients. The new bite block was designed and implemented in light of previous studies. The height of the new bite block was 18 mm and to compensate for the horizontal edentulous space, its horizontal width was 7 mm. The panoramic radiographs using the new bite block were compared with those using the conventional chin-support device. Results: Panoramic radiographs taken with the new bite block showed better stability and bilateral symmetry than those taken with the conventional chin-support device. Patients also showed less movement and more stable positioning during panoramic radiography with the new bite block. Conclusion: Conventional errors in panoramic radiographs of edentulous patients could be caused by unreliability of the chin-support device. The newly proposed bite block for panoramic radiographs of edentulous patients showed better reliability. Further study is required to evaluate the image quality and reproducibility of images with the new bite block.

Rare Case Report on Nevus of Ota

  • Chandak, Rakhi;Degwekar, Shirish;Chandak, Manoj;Bhowte, Rahul;Rawlani, Shivlal
    • Journal of Korean Dental Science
    • /
    • v.3 no.1
    • /
    • pp.43-47
    • /
    • 2010
  • Nevus of Ota is a hamartoma of dermal melanocytes. Clinically, Nevus of Ota is manifested as blue or gray patch on the face; such condition is congenital or acquired and is within the distribution of branches of the trigeminal nerve. The nevus can be unilateral or bilateral. In addition to skin, it may involve ocular and oral mucosal surfaces. The case of an 18-year old female with unilateral bluish black macule on the right side of the face since birth is presented. She also had a bluish patch on the right shoulder at birth, which disappeared when she turned 10 years. The pathogenesis of Nevus is unknown, and effective treatment has been realized with pigment-specific lasers.

  • PDF

Condylar jugular diverticulum: A report of 3 cases

  • Jagtap, Rohan;Wazzan, Taggreed;Hansen, Matthew;Kashtwari, Deeba
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.251-256
    • /
    • 2019
  • Jugular bulb diverticulum is an irregular extension of the jugular bulb into the temporal bone that may be symptomatic or asymptomatic. The jugular bulb has rarely been reported to extend into the occipital condyle; such extension is termed a condylar jugular diverticulum and is characterized as a defect in the occipital condyle contiguous with the jugular bulb. This report details 3 cases of condylar jugular diverticulum. Extension of the jugular bulb into the ipsilateral occipital condyle was noted as an incidental finding on cone-beam computed tomographic (CBCT) images of 3 patients. All 3 patients were asymptomatic, and this finding was unrelated to the initial area of interest. CBCT use is becoming ubiquitous in dentistry, as it allows 3-dimensional evaluation, unlike conventional radiography. Proper interpretation of the entire CBCT is essential, and recognition of the indicators of condylar jugular diverticulum may prevent misdiagnosis of this rare entity.