Combined Exercise in Premenopausal Women Effects on Body Composition and Bone Mineral Density (복합운동이 폐경 전 성인여성의 신체조성 및 골밀도에 미치는 영향)

  • Kim, Kyung-Hee;Lee, Jung-Hee;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.145-155
    • /
    • 2017
  • The purpose of this study was to compare and analyze changes in body composition and bone mineral density (BMD) during combined exercise in premenopausal women who did not take regular diet or regular physical activity within 6 months, In addition to being able to recognize the importance of pre-menopausal women's health and exercise, it also provides basic data for the development of educational programs for early prevention of osteoporosis prevention education I want to. The average age of the subjects in their 30s was 35.44 years and their height was 158.89 cm in their 30s. The average age of the subjects in their 40s was 41.89 and their average height was 160.78 cm in their 40s. Body composition, BMI, and body fat percentage were higher in the 30s, and bone mineral content, lean body mass, skeletal muscle mass, body weight, body fat mass and waist circumference were higher in their forties. Lumbar spine BMD and femur density were higher in their 30s than their 40s. Body composition, skeletal muscle mass, and fat mass increased in the 30s body composition by age - related complex exercise in premenopausal women, body fat mass, body fat percentage, waist circumference decreased. Body mass, body fat, body fat percentage, and BMI decreased in the 40s. The lumbar spine, the lumbar spine, the lumbar spine, and the femur were increased in the lumbar spine, the lumbar spine, the femur, and the femur. In the post-analysis results, changes in body composition were statistically significant due to decrease in muscle mass, body weight, body fat mass and BMI after combined exercise. In the change of bone density, lumbar spine BMD was measured as lumbar spine 1, lumbar spine 2, lumbar spine 3, And the femur density was increase.

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

Nuclear Terrorism and Global Initiative to Combat Nuclear Terrorism(GICNT): Threats, Responses and Implications for Korea (핵테러리즘과 세계핵테러방지구상(GICNT): 위협, 대응 및 한국에 대한 함의)

  • Yoon, Tae-Young
    • Korean Security Journal
    • /
    • no.26
    • /
    • pp.29-58
    • /
    • 2011
  • Since 11 September 2001, warnings of risk in the nexus of terrorism and nuclear weapons and materials which poses one of the gravest threats to the international community have continued. The purpose of this study is to analyze the aim, principles, characteristics, activities, impediments to progress and developmental recommendation of the Global Initiative to Combat Nuclear Terrorism(GICNT). In addition, it suggests implications of the GICNT for the ROK policy. International community will need a comprehensive strategy with four key elements to accomplish the GICNT: (1) securing and reducing nuclear stockpiles around the world, (2) countering terrorist nuclear plots, (3) preventing and deterring state transfers of nuclear weapons or materials to terrorists, (4) interdicting nuclear smuggling. Moreover, other steps should be taken to build the needed sense of urgency, including: (1) analysis and assessment through joint threat briefing for real nuclear threat possibility, (2) nuclear terrorism exercises, (3) fast-paced nuclear security reviews, (4) realistic testing of nuclear security performance to defeat insider or outsider threats, (5) preparing shared database of threats and incidents. As for the ROK, main concerns are transfer of North Korea's nuclear weapons, materials and technology to international terror groups and attacks on nuclear facilities and uses of nuclear devices. As the 5th nuclear country, the ROK has strengthened systems of physical protection and nuclear counterterrorism based on the international conventions. In order to comprehensive and effective prevention of nuclear terrorism, the ROK has to strengthen nuclear detection instruments and mobile radiation monitoring system in airports, ports, road networks, and national critical infrastructures. Furthermore, it has to draw up effective crisis management manual and prepare nuclear counterterrorism exercises and operational postures. The fundamental key to the prevention, detection and response to nuclear terrorism which leads to catastrophic impacts is to establish not only domestic law, institution and systems, but also strengthen international cooperation.

  • PDF

The Bone Mineral Density Impact Factors of Adult Women before the Menopause - based on the National Health and Nutrition Examination Survey - (폐경 전 성인여성의 골밀도 영향 요인 - 국민건강영양조사 자료를 이용하여 -)

  • Kim, Kyung-Hee;Lee, Jung-Hee;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.147-168
    • /
    • 2015
  • In this research, we have analyzed the impact factors on the bone mineral density thru the examination of bone density difference in the entire femur, femoral neck and lumbar of adult women before the menopause in accordance with the general features, lifestyle, eating habits, health and body composition. The survey was conducted among adult women before the menopause and older than 30 years based on the data of the National Health and Nutrition Examination Survey carried out in the 4th term (2008-2009) and 5th term (2010-2011) and we would like to provide the research results for the establishment of recommendations or guidelines for the treatment of adult women before the menopause with regard to the impact factors on the bone mineral density and for the development of health education materials for the accurate measurement of bone mineral density of young women in order to prevent the postmenopausal osteoporosis. With respect to the general features of adult women before the menopause, the bone mineral density was higher in the entire femur at age 40-44, femoral neck at 35-39, in high-school education level, in the earlier menarche group, without smoking experiences, with regular walking time and exercise frequency and with the habits of eating no hamburger or pizza. With regard to the body composition, the bone mineral density was higher in obesity and lower in underweight cases, higher among people with abdominal obesity and weight control experiences. In terms of total body fat ratio, total amount of fat and muscle, the bone mineral density got gradually increased from the 1st quarter (Q1) to the 4th quarter(Q4). The obesity, disease, total amount of fat and muscle were shown to be significantly related with the bone mineral density in this research and it is required for young women to keep the adequate weight and the normal BMI in order to increase the bone mineral density. For the prevention of osteoporosis, it is advised to keep the right habits including regular exercise and no smoking discipline from the growing period and achieve the maximum bone mass thru the control of proper weight from a young age.

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

A Comparative Study on the Quality of Living for Therapeutic Cancer and Hospiece Patients (치료 암환자와 호스피스 환자에 대한 삶의 질 비교)

  • Kim SeungKook;Rhee DongSoo;Rou JaeMan;Kim JongDeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.79-89
    • /
    • 2004
  • This study carried a comparative analysis of quality of living perceived by cancer and hospiece patients who received radiotheraphy, and influential factors in order to provide basic data for nursing goals and establishment of strategy. The subjects of the study were 50 cancer patients who were more than twenty years old and was receiving radiotheraphy in therapeutic radiology department of C university hospital, and fourteen hospiece patients who were in J hospital in Gwangju. They were conveniently sampled according to the selection standard, and researchers personally interviewed them using questionnaire and patient scripts to obtain necessary data. The results were presented as follows: 1. When cancer and hospiece patients were examined demographically, the number of 60 year-old patients were the most. The subjects whose marriage period was more than thirty-one years were the most. In medical expense, more than $70.0\%$ of the patients bore their expenses themselves. 2. When disease-related characteristics of the cancer and pospiece patients were exmained, more than $75\%$ of the patients had experience of being in hospital, and more than $60.0\%$ experienced operation. However, for prevalence period, $57.5\%$ of the cancer patients had less than six months, and $64.3\%$ of the hospiece patients had more than two years. 3. For physical symptoms of cancer patients, $77.5\%$ had fatigue, $60.0\%$ had loss of appetite, and $52.5\%$ had loss of weight while for the hospiece patients, $100\%$ had loss of weight, and $92.9\%$ had fatigue and loss of appetite. For the cancer patients, $0.0\%$ had swelling, and $7.5\%$ had bleeding, For the hospiece patients, $7.1\%$ had change in skin, and $14.3\%$ had diarrhea. 4. Mean score of the cancer subjects were as follows: family support, social support, emotional and spiritual support, physical symptoms, and periods were 3.87, 2.88, 3.10, 2.80, and 2.94 respectively. Those of the hospiece patients were 3.80, 1.96, 1.58, 2.64 and 3.24 respectively. 5. Mean score of family support of both patients were almost identical, but in character, a considerable difference was found: 3.10 and 1.58. In qualify of living, the mean score of hospiece patients was slightly lower.

  • PDF

Relationship between Knowledge, Attitude, Behavior, and Self-Efficacy on the Radiation Safety Management of Radiation Workers in Medical Institutions (의료기관 방사선종사자의 방사선안전관리에 대한 지식, 태도 및 행위와 자기효능감 간의 관련성)

  • Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • Radiation safety managements in medical institutions are needed to protect certain radiation damages as a part of National Coalition. This study investigates the characteristics of self-efficacy that become the major factor on the knowledge, attitude, and behavior on the radiation safety management of radiation workers as an approach of educational aspects and analyzes the relationship between such factors to provide basic materials for improving the activity level of radiation safety managements. In order to implement the goal or this study, a survey was performed for 1,200 workers who were engaged in radiation treatments in medical centers, such as general hospital, university hospital, private hospital, and public health center for 42 days from July 23,2006. Then, the results of the analysis can be summarized as follows: 1. Average scores on knowledge, attitude, and behavior in the radiation safety management were presented as $75.76{\pm}11.20$, $90.55{\pm}8.59$, $80.58{\pm}11.70$, respectively. Also, the average score of self-efficacy was recorded as $73.55{\pm}9.82$. 2. Knowledge levels in the radiation safety management showed significant differences according to the sex, age, marriage, education, and experience. Also, males of married, older, highly educated, and largely experienced represented high knowledge levels. Attitude levels in the radiation safety management showed certain significant differences according to the type of medical centers in which private hospitals showed a relatively low level compared to that of high levels in university hospitals. Behavior levels in the radiation safety management also represented significant differences according to the age, marriage, education, experience, and types of medical centers. Factors in married, general hospital, older, highly educated, and largely experienced showed high behavior levels. In addition, the self-efficacy showed certain differences according to the marriage and types of medical centers. Factors in married and general hospital demonstrated high self-efficacy levels. 3. Relationship between knowledge, attitude, behavior, and self-efficacy on the radiation safety management showed statistical differences according to the relationship between the knowledge and the attitude, the knowledge and the behavior, the attitude and the behavior, the attitude and the self-efficacy, and the behavior and the self-efficacy. The relationship between the behavior and the self-efficacy was represented as r = 0.482, which was the strongest relationship in such factors. Also, the knowledge and self-efficacy didn't show certain relationships.

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF

Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study) (수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로))

  • CHOI, Sung-Hyun;JO, Hwang-Woo;Dong, Kyung-Rae;Chung, Woon-Kwan;Choi, Eun-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.