• Title/Summary/Keyword: Radiological technology

Search Result 2,476, Processing Time 0.038 seconds

Protective Effects of Chitosanoligosaccharide on Gamma Ray-Induced Hepatic Damage in Mice (생쥐에서 키토산올리고당의 감마선 저항 효과)

  • Kim, Jung-Sam;Roh, Young-Bok
    • Applied Microscopy
    • /
    • v.33 no.2
    • /
    • pp.155-168
    • /
    • 2003
  • The purpose of this study was to evaluate the effect the radiation-resistance of chitosan on the mice. A healthy male ICR mice were used for experiment. The SOD and MDA activity was measured from the liver of mice at 48 and 72 hours after the irradiation. The ultrastructural changes of the liver by irradiation was observed at 24, 48 and 72 hours after irradiation. The experimental groups were divided into three groups. Group 1 was the control group which was not treated with chitosanoligosaccharide before or after iradiation. Group 2 was the prefeeding group which chitosanoligosaccharide solution was supplied by feeding ad libitum for 30 days before irradiation. Group 3 was the postfeeding group which chitosanoligosaccharide solution was supplied by feeding after irradiation. In all groups 10 mice were used. The results were as follow: The SOD and MDA activity of the prefeeding group was decreased significantly (P<0.01). Control group - The nuclei were condensed. The mitochondria and rough endoplasmic reticulum (rER) were extended and the ribosome was dropped from the rER. Prefeeding group - The nuclei were rounded. The mitochondria was elongated. And the rER attached ribosomes. Postfeeding group - The nuclei were slightly condensed. The mitochondria and the rER were extended and the ribosome was dropped from the rER. It was concluded that the chitosanoligosaccharide was effective in the radiation-protection. So, chitosan would have the potential as the radiation-protection materials.

Radiation Dose using Chest CT for Patients with Pneumoconiosis Complication - Comparison with International Guidelines - (진폐요양환자의 흉부 CT촬영에 사용된 선량 - 국내외 진단 참고 준위와 비교 -)

  • Lee, Won-Jeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.206-212
    • /
    • 2014
  • We report here on the results of evaluating the radiation doses using chest computed tomography (CT) for patients with pneumoconiosis complication. For the first time, we visited the 17 MIPs to evaluate the dose-length product (DLP, $mGy{\cdot}cm$), CT unit, and protocols of scanning and image reconstruction those is routinely used for treating patients with pneumoconiosis who have complication. All statistical analysis was performed using the Statistical Program for Social Sciences (SPSS ver. 19.0, Chicago, IL, USA). Mean of total DLP was $727.7mGy{\cdot}cm$, ranging from 272.0 to $1228.7mGy{\cdot}cm$. DLP from obtaining parenchymal lung images was significantly reduced than that from obtaining total lung images (555.9 vs. 707.2, p<0.001). Third quartile of total and pre-scanning DLP was 1036.1 and $504.1mGy{\cdot}cm$, respectively. Chest CT radiation doses for patients with pneumoconiosis complication are similar with korean diagnostic reference level as well as international guidelines.

A Comparative Study on the Head and Neck Radiation Therapy for Dynamic Conformal Arc Therapy and Volumetric Modulated Arc Therapy (두경부 방사선 치료 시 입체조형동적회전조사치료와 용적변조회전조사치료에 관한 연구)

  • Kim, Deok-Ki;Choi, CheonWoong;Choi, Jae-hyock;Won, Hui-su;Park, Cheol-soo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.6
    • /
    • pp.208-218
    • /
    • 2015
  • Recently, radiation therapy is used in the CT existing conventional two-dimensional radiation image, and set the size and location of the tumor in a manner that the image is going to change the treatment plan. After using the simulation using CT, radiation therapy it is four-dimensional or three-dimensional treatment made possible. and radiation therapy became the more effective ever before. High technology radiation therapy such as the treatment of SRS,IMRT, IGRT, SBRT, is a need to try contemplating the possibility to apply appropriate analysis and situation, so it has its own characteristics. and then it is believed that it is necessary to analyze and try it worries the proper applicability of the situation. The configuration of the various treatment that is applicable in many hospitals is necessary to try to determine how to practically apply the patients. Critical organs surrounding tumor give a small dose to avoid side effects and then the tumor has the therapeutic effect by providing a larger dose than before the radiation treatment.

The effect of Bu-Zhong-Yi-Qi-Tang on ultraviolet B-induced skin damages in mouse (자외선 B 조사 마우스에서 피부손상에 대한 보중익기탕의 효과)

  • Kim, Joong-Sun;Lee, Hae-June;Song, Myoung-Sub;Seo, Heung-Sik;Moon, Changjong;Kim, Jong-Choon;Bae, Chun-Sik;Jo, Sung-Kee;Kim, Sung-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.49 no.1
    • /
    • pp.17-22
    • /
    • 2009
  • The effect of Bu-Zhong-Yi-Qi-Tang (BZYQT) on the changes of ultraviolet (UV) light B radiation-induced apoptotic sunburn cell (SBC) and epidermal ATPase-positive dendritic cell (DC) in SKH1- hr or ICR mouse were investigated. The mice were treated with UVB (200 mJ/$cm^2$) and were sacrificed 24 h later. BZYQT (50 mg/kg of body weight) or vehicle (saline) was given i.p. at 36 and 12 h before irradiation, and 30 min after irradiation or BZYQT cream (0.2%) or cream base (vehicle) was topically treated at 24 h and 15 min before irradiation, and immediately after irradiation. The skin of SKH1-hr mouse prepared from the back of untreated mice exhibited about 0.3 SBC/cm length of epidermis, and 24 h after UV irradiation, the applied areas show an increased number of SBCs. But the frequency of UVB-induced SBC formation was reduced by intraperitoneal injection of BZYQT extract (p < 0.01). The numbers of DC in normal ICR mouse were 628.00 ${\pm}$ 51.56 or 663.20 ${\pm}$ 62.58 per $mm^2$ of ear epidermis. By 1 day after UVB treatment, the number of ATPase-positive cells/$mm^2$ were decreased by 39.0% or 27.1% in i.p. or topical application group with vehicle. Treatment of BZYQT was associated with increase of 33.9% in i.p. group (p < 0.05) or 2.7% in topical application group in the number of ATPase positive cells compared with the irradiation control group. The results presented herein that BZYQT administration could reduce the extent of skin damages produced by UVB.

Study on the Institutional Control Period Through the Post-drilling Scenario Of Near Surface Disposal Facility for Low and Intermediate-Level Radioactive Waste (중·저준위 방사성폐기물 천층처분시설에서 시추 후 거주시나리오 평가를 통한 폐쇄 후 제도적 관리기간 연구)

  • Hong, Sung-Wook;Park, Jin-Baek;Yoon, Jung-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.59-68
    • /
    • 2014
  • The public's access to the disposal facilities should be restricted during the institutional control period. Even after the institutional control period, disposal facilities should be designed to protect radiologically against inadvertent human intruders. This study is to assess the effective dose equivalent to the inadvertent intruder after the institutional control period thorough the GENII. The disposal unit was allocated with different kind of radioactive waste and the effects of the radiation dose to inadvertent intruder were evaluated in accordance with the institutional control period. As a result, even though there is no institutional control period, all were satisfied with the regulatory guide, except for the disposal unit with only spent filter. However, the disposal unit with only spent filter was satisfied with the regulatory guide after the institutional control period of 300 years. But the disposal unit with spent filter mixed with dry active waste could shorten the institutional control period. So the institutional control period can be reduced through the mixing the other waste with spent filter in disposal unit. Therefore, establishing an appropriate plan for the disposal unit with spent filter and other radioactive waste will be effective for radiological safety and reduction of the institutional control period, rather than increasing the institutional control period and spending costs for the maintenance and conservation for the disposal unit with only spent filter.

Analysis of change of internal organ in the Inter-and Intrafraction using MVCT (MVCT를 이용한 치료 간(Interfraction) 그리고 치료 중(Intrafraction) 내부 장기 변화 분석)

  • Jung, Won Seok;Kim, Ju Ho;Kim, Young Jae;Shin, Ryung Mi;Oh, Jeong Hun;Jeong, Geon A;Jo, Jun Young;Kim, Gi Chul;Choi, Tae Kyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.115-126
    • /
    • 2014
  • Purpose : Depending on a variety of therapeutic areas using MVCT(Megavoltage computed tomography) intra-and interfraction is to evaluate changes in patient position. Materials and Methods : In this study, head and neck, thorax, liver, and prostate tumor patients, 48 people with a full course of treatment for patients with various MVCT scan was performed. Average 60 per patient MVCT images were acquired and analyzed. Results : Interfraction error thorax and abdomen, and pelvis in the longitudinal difference was more than 3 mm. Intrafraction to see a change after the end of treatment MVCT taken, and the results confirmed Intrafraction 2 mm in motion around the longitudinal difference. In addition, due to changes in the movement before and after treatment, Inter-and Intrafraction difference was found. Conclusion : In the present study, the Head and Neck, Thorax, liver, prostate cancer in patients with inter-and intrafraction changes and target the appropriate fixtures to complete the outline of the margin would be helpful is considered.

The effect of patient position on dose in radiation therapy of liver cancer (환자 자세가 간의 방사선 치료 시 선량에 미치는 영향)

  • Jung, Won Seok;Kim, Ju Ho;Kim, Young Jae;Shin, Ryung Mi;Oh, Jeong Hun;Jeong, Geon A;Jo, Jun Young;Kim, Gi Chul;Choi, Tae Kyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Purpose : To analyze tumor's movement and volume change from changing position in order to minimize movement caused by breathing. Materials and Methods : We conducted survey of 14 patients with HCC(Hepatocellular carcinoma). Patient immobilization device was made in two ways(Supine position, prone position) and from image acquisition, tumor's movement, volume and dose are analyzed. Results : The mean movement of target(LR, Left-right) in supine position and prone position was $2.76{\pm}1.25mm$, $2.21{\pm}0.93mm$. AP(Anterior-posterior) and SI(Superior-inferior) was $4.02{\pm}1.63mm$, $11.56{\pm}3.08mm$, $3.36{\pm}1.17mm$, $7.45{\pm}1.96mm$. Treatment volume was decreased and normal liver volume was increased in prone position. Conclusion : We could reduce the margin of the treatment volume by minimizing the movement of liver caused by breathing. Especially in prone position, it is considered to be able to decrease the movement of the liver and increase normal liver volume.

Differences in Target Volume Delineation Using Typical Radiosurgery Planning System (각각의 방사선수술 치료계획시스템에 따른 동일 병변의 체적 차이 비교)

  • Han, Su Chul;Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.265-270
    • /
    • 2013
  • Correct target volume delineation is an important part of radiosurgery treatment planning process. We designed head phantom and performed target delineation to evaluate the volume differences due to radiosurgery treatment planning systems and image acquisition system, CT/MR. Delineated mean target volume from CT scan images was $2.23{\pm}0.08cm^3$ on BrainSCAN (NOVALS), $2.13{\pm}0.07cm^3$ on Leksell gamma plan (Gamma Knife) and $2.24{\pm}0.10cm^3$ on Multi plan (Cyber Knife). For MR images, $2.08{\pm}0.06cm^3$ on BrainSCAN, $1.94{\pm}0.05cm^3$ on Leksell gamma plan and $2.15{\pm}0.06cm^3$ on Multi plan. As a result, Differences of delineated mean target volume due to radiotherapy planning system was 3% to 6%. And overall mean target volume from CT scan images was 6.36% larger than those of MR scan images.

Pulmonary Function and Influence Factors among Residents around Gwangyang Steel Mill (광양 제철소 주변지역 거주자들의 폐기능과 영향 요인)

  • Hong, Eun-Ju;Ahn, Gi-Sub;Chung, Eun-Kyung;Choi, Jae-Ho;Guo, Xinbiao;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.182-192
    • /
    • 2011
  • Objectives: This study aims to identify the influential factors on the pulmonary function of targeted general residents in the areas surrounding Gwangyang Steel Mill. Methods: An PFT (Pulmonary Function Test) was conducted from May 2007 to November 2007 on 974 target residents (438 male, 536 female), including an exposed group (674 people) who resided within a radius of 5 km from Gwangyang Steel Mill in Gwangyang-si, Jeollanam-do and a control group (300 people) who resided outside a radius of 15 km. A survey related to personal characteristics, life habits, respiratory diseases and allergic symptoms, medical histories and living environments of the residents was also conducted to identify influential factors on pulmonary function. Results: As %$FEV_1$ and %FVC of the exposed group are 99.17% and 96.98%, respectively, and those of the control group are 105.47% and 101.91%, respectively, with the PFT values of the exposed group being lower than those of the control group (p<0.001), it turns out that the pollution in the industrial complex is likely to trigger a reduction in the pulmonary function of local residents. The odds ratio analysis result for asthma diagnosis history indicates that the odds ratios tend to be higher among surveyed residents who are living near above-average traffic volumes and are using beds, where it is statistically meaningful that especially the odds ratios are higher if the residences are closer to roads (p<0.01, CI=1.12-4.52). The factors that affect the FEV1 are identified as smoking, passive smoking, asthma diagnosis history, nasal congestion symptoms and allergic eye disease ($R^2$=0.154, p<0.001). The factors that affect the FVC are identified as smoking, passive smoking, asthma diagnosis history and allergic coryza ($R^2$=0.158, p<0.001). In addition, the analysis result for the relevance of air pollution levels to pulmonary function ($FEV_1$, FVC) shows that FEV1 and FVC tend to decrease as the concentration of $O_3$ increases. Conclusions: We believe that this study may provide preliminary data for the development of preventive measures for health effects on the residents and environmental health control measures for environmental pollution in the industrial complex area.

Evaluating the Effectiveness of Work with the Remote System in PACS Room (PACS실에서 원격시스템을 이용한 업무의 효율성 평가)

  • Kim, Ji-Hye;Lee, Jong-Woong;Lee, Seung-Jin;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.171-175
    • /
    • 2011
  • Server and Pi view management, external image and internal image Copy Import business in PACS room is through the medical assistance. Import and Copy, and in particular the number of cases is increasing the number of import is a fast growing trend. Although the increase in workload With limited human resources to increase business efficiency so Remote system is using PACS room. This remote system will want to evaluate the effectiveness of using the service. Amount of data each 437.5 MB, Copy and Import time is to compare and evaluate sees by use 1 PC. 4 PC, 4 PC+ remote system. The use of the remote system before the January 2010 to June daily average waiting time and the use of the remote system after the January 2011 to June compared to a daily average patient waiting time, evaluate. Using the remote system in January 2011 to June Find out the average remote utilization. The biggest difference on the four copy and eight continued, Were performed two times faster by use 4 PC+ remote system than use 4 PC and four times faster than use 1 PC. Before using the remote system, the daily average wait time is 14.5 minutes after using the daily average 10.2 minutes, waiting time 30% of the existing waiting time was 4.3 minutes, to reduce. Using the remote system in January 2011 to June the average daily number of cases is 107 number and The number of remote and on average 35 cases with 32% in a day remote usage. The use of the remote system to Import, CD Copy and greatly increase the efficiency of their time could be. Hours due to efficiency could also reduce customer waiting time. As a result, the manpower and the use of a remote system over time to maximize efficiency in business hours, work was evaluated by.

  • PDF