• Title/Summary/Keyword: Radiologic Science

Search Result 479, Processing Time 0.025 seconds

The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography (Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향)

  • Kwon, Soonmu;Park, Changhee;Park, Jeongkyu;Son, Woonheung;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • Chest radiography has been typically performed at SID of 180 cm. Image quality and patient dose were investigated between 180 cm and 340 cm by 20 cm intervals at 120 kVp and 320 mAs with the AEC. VGA was performed for qualitative assessment and SNR was analysed for quantitative assessment on the image of the chest phantom. Patients dose was measured by ESAK and PCXMC was used for effective dose. As a result, when using the standard of SID of 180 cm which is typically used in the clinical practice, in the case of ESAK, 240 cm, 280 cm, and 320 cm were 8.7%, 11.47%, and 13.56% respectively therefore significant reduction was confirmed. In the case of effective dose, 2.89%, 4.67%, and 6.41% in the body and 5.08%, 6.09%, and 9.6% in lung were reduced. In the case of SNR, 9.04%, 8.24%, and 11.46% were respectively decreased especially, by 8.03% between SID of 260 cm and 300 cm, but SNR was 5.24 up to 340 cm. There were no significant differences in VGA thus the image is valuable in diagnosis. It is predicted that increasing SID up to 300 cm in digital chest radiography can reduce patient dose without decreasing image quality.

Quality Management for Mammography Equipment and Mammography (유방촬영장치와 유방검사를 위한 품질관리)

  • zheng, Hao Yang;Cho, Pyong Kon;Kim, Tae Woo;Kim, Jung Soo;Jang, Hyon Chol;Lee, Mi Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.683-692
    • /
    • 2018
  • Mammography using mammography equipment is a method of examination that is being employed most widely to diagnose the early stages of breast cancer. Detecting or diagnosing a fibrous tissue, micro calcification, or mass in the breast is influenced by the quality management of mammography equipment considerably. Particularly in mammography, quality management refers to a behavior of figuring out and correcting all sorts of hindrance factors that can cause all the problems related to the equipment associated with the diminishment of diagnosed area due to the reduction of image quality in clinical imaging in advance and maintaining a consistent level of image quality and obtaining a proper image. Here, these researchers aim to summarize and report the general contents of quality management in mammography using mammography equipment.

The Use of Continuous Confidence Judgments in ROC of Digital Radiography (디지털 X선영상 평가에서 연속확신도법 ROC의 적용)

  • Kim, Hark-Sung;Lee, In-Ja;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.147-151
    • /
    • 2009
  • In general, the discrete confidence judgments that use five-step assessment method have been used to assess the medical images by ROC. TPF or FPF can be computed easily with this independent reading test. However, during experiments, it happens frequently that adequate distribution for observers is required to smoothly estimate the ROC curve. In addition, data becomes invalid for distribution of the created categories. To solve such problems or to apply the ROC interpretation to data that is not obtained from the experimental observation, the continuous confidence judgements (CCJ) has been proposed, which implements ROC interpretation using continuously-distributed experimental results without category classification has been used. As the use of CCJ to assess medical images was barely reported in Korea, we applied it to the assessment of chest digital images in this study. The results showed that a smooth ROC curve was obtained conveniently by the commercialized program and the characteristic value was measured easily. Therefore, it is recommended that this method can be applied to the assessment of digital medical images.

  • PDF

Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography (CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과)

  • Jung, Mi-Young;Kweon, Dae-Cheol;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.307-312
    • /
    • 2009
  • The purpose of our study was to determine the eyeradiation dose when performing routine multi-detector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth eye shield when performing head MDCT. Examinations were performed with a 64MDCT scanner. To compare the shielded/unshielded lens dose, the examination was performed with and without bismuth shielding in anthropomorphic phantom. To determine the average lens radiation dose, we imaged an anthropomorphic phantom into which calibrated photoluminescence glass dosimeter (PLD) were placed to measure the dose to lens. The phantom was imaged using the same protocol. Radiation doses to the lens with and without the lensshielding were measured and compared using the Student t test. In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded brain. The mean radiation doses to the eyewith the shield and to those without the shield were 21.54 versus 10.46 mGy, respectively. The lens shield enabled a 51.3% decrease in radiation dose to the lens. Bismuth in-plane shielding for routine eye and head MDCT decreased radiation dose to the lenswithout qualitative changes in image quality. The other radiosensitive superficial organs specifically must be protected with shielding.

  • PDF

Evaluating the Effects of Inferiority Management Using a Group Counseling Program for University Students in Health Science (보건계열 대학생의 집단상담 프로그램을 활용한 열등감 관리의 효과 분석)

  • Lee, Myung Hwa;Park, Young Joon;Jang, Hyon Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.557-563
    • /
    • 2019
  • The objective of this study was to identify factors affecting the positive and negative responses of undergraduate students to inferiority by using a group counseling program to manage the inferiority of undergraduate students majoring in health science. This study sampled 30 undergraduate students attending the health science department of S University and divided them into a treatment group and a control group. The treatment group received an inferiority management group counseling program twice a week 120 minutes each from November 20, 2018, to January 2, 2019 eight sessions in total. The inferiority response criterion was applied before-treatment, after-treatment, and follow-up to verify the effectiveness of the program. The analysis results showed that the inferiority management group counseling program significantly decreased the negative response of undergraduate students to inferiority and significantly increased the positive response to inferiority. These results suggest that the inferiority management counseling program can lower the negative attitude and enhance the positive attitude toward the inferiority, which is caused by comparing themselves with their peers.

Proposal of CT Simulator Quality Assurance Items (전산화단층 모의치료장치의 정도관리 항목 제안)

  • Kim, Yon-Lae;Yoon, Young-Woo;Jung, Jae-Yong;Lee, Jeong-Woo;Chung, Jin-Beom
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.367-373
    • /
    • 2021
  • A quality assurance of computed tomography(CT) have done seven items that were water attenuation coefficient, noise, homogeneity, spatial resolution, contrast resolution, slice thickness, artifact using by standard phantom. But there is no quality assurance items and methods for CT simulator at domestic institutions yet. Therefore the study aimed to access the CT dose index(CTDI), table tilting, image distortion, laser accuracy, table movement accuracy and CT seven items for CT simulator quality assurance. The CTDI at the center of the head phantom was 0.81 for 80 kVp, 1.55 for 100 kVp, 2.50 for 120 mm, 0.22 for 80 kVp at the center of the body phantom, 0.469 for 100 kVp, and 0.81 for 120 kVp. The table tilting was within the tolerance range of ±1.0° or less. Image distortion had 1 mm distortion in the left and right images based on the center, and the laser accuracy was measured within ±2 mm tolerance. The purpose of this study is to improve the quality assurance items suitable for the current situation in Korea in order to protect the normal tissues during the radiation treatment process and manage the CT simulator that is implemented to find the location of the tumor more clearly. In order to improve the accuracy of the CT simulator when looking at the results, the error range of each item should be small. It is hoped that the quality assurance items of the CT simulator will be improved by suggesting the quality assurance direction of the CT simulator in this study, and the results of radiation therapy will also improve.

A Case Report of Cholangiocarcinoma Arising from a Biliary Adenofibroma: Radiologic Findings and Review of Literature (담도선섬유종에서 발생한 담관암: 증례 보고 및 문헌적 고찰)

  • Hyun-Ji Lim;Mi-Suk Park;Young Nyun Park;Sun Il Kim;Yeo-Eun Kim;Cheong Hoon Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.721-728
    • /
    • 2021
  • Biliary adenofibromas are rare biliary epithelial tumors that are classified as benign. Nevertheless, some cases have been reported to show malignant transformations. The radiologic findings of biliary adenofibromas and their malignant transformation are not well-established because of their rarity. We present a case of a cholangiocarcinoma arising from a biliary adenofibroma assessed using ultrasonography, CT, and MRI. The differential diagnoses include other hepatic tumors.

The Odontogenic Keratocysts : A Consideration of the Clinical and Radiologic Features (치성각화낭 : 임상 및 방사선학적 고찰)

  • Lee Ji-Youn;Lee Jang- Yeol;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.199-205
    • /
    • 2000
  • Purpose: To determine whether the significant relationship exists between radiographic appearance, whether it is unilocular or multilocular, and its corresponding clinical and histologic features by examining the odontogenic keratocyst clinically, radiologically and histologically. Materials and Methods: This study was conducted on 48 cases of odontogenic keratocyst from the files of Dental Hospital, Yonsei University for the years 1982 through 1995. Results and Conclusions : The mean age of patients was 30.5 years in the unilocular group and 35.5 years in the multilocular group. The male to female ratio was 1 : 1.06 in the unilocular group and 1 : 1.75 in the multilocular group. The chief complaint was swelling in both groups(unilocular 35.1 %, multilocular 54.5%). In the occurrence site, the border of the lesion, the displacement and external root resorption of the adjacent teeth, there were no statistically significant difference between the unilocular group and multilocular group, but in the border type, there was statistically significant difference (x²-test, p<0.05)wo recurred cases were observed among 11 cases of odontogenic keratocyst. One was unilocular case and the other was multilocular case.

  • PDF

Ultrastructure of Spermatozoa of the Slender Catfish, Pseudobagrus brevicorpus (Teleostei, Bagridae) with Phylogenetic Considerations (꼬치동자개 (Pseudobagrus brevicorpus) 정자의 미세구조와 계통적 고찰(경골어류, 메기목, 동자개과))

  • KIM Kgu Hwan;LEE Joon Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.480-485
    • /
    • 2003
  • Morphology of the spermatozoa from the testes of the catfish (Pseudobagrus brevicorpus) was studied by transmission and scanning electron microscopy. The spermatozoa of P. brevicorpus are approximately $82.25\pm0.06\;{\mu}m$ in length and relatively simple cells composed of a spherical head, a short midpiece and a tail as in most teleost fish, The nucleus measuring about $2.00\pm0.02\;{\mu}m$ in length is depressed with a deep nuclear fossa of about $1.05\pm0.03\;{\mu}m$ in length three fifths of the nuclear length. The nuclear fossa contains the proximal and distal centrioles. The two centrioles are oriented approximately $150^{\circ}$ to each other. The mitochondria are arranged in two layers and their number is 12 or more. They are separated from the axoneme by the cytoplasmic canal. The axoneme is the 9+2 microtubular pattern and has inner but no outer dynein arms as in other bagrids. The axonemal fins were the closed to axonemal doublet 3 and 8. The axonemal fins and lost outer dynein arm are shared in Bagridae and the deep nuclear fossa is shared in Siluriformes. The axonemal fins observed in Bagridae and Amblycipitidae of Siluriformes might be the apomorphic character in Ostariophysi.

A Study on Reduction Effect of Processing Wastewater by Introduction of PACS (PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구)

  • Ko, Shin-Kwan;Han, Dong-Kyoon;Kim, Wook-Dong;Kang, Bung-Sam;Yang, Han-Jun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.167-175
    • /
    • 2007
  • There are some positive effects by the introduction of PACS(Picture Archiving Communication System). This study is to analyze the mutual relation between before and after of the introduction of PACS in terms of the environment effect. It is supposed to cause the reduction of developing and fixing wastewater according to the increase in the rate of a non-film. This study will also show the amount of wastewater. Target places were the department of image medicine(diagnostic radiation) of the general hospitals in Seoul and Gyeonggi-Do, which are equiped with full PACS. The authors examined questionnaires on the number of projection, the number of indirect projection, the amount of the film used, the number of radiation image CD loan, the amount of the developing and fixing solution used, the change of the amount of fixing wastewater. According to the analysis, we analyzed the change of the amount of developing and fixing solution per a film and the change of the amount of developing and fixing wastewater which is supposed to be reduced proportionally by the introduction of PACS. We got conclusion as below after analyzing 8 hospitals except the largest and the least amount of examination, film used, developing and fixing solution and the amount of developing and fixing wastewater in order to decrease the deviation from 10 general hospitals located in Seoul and Gyeonggi-Do. We compared data one year before adopting PACS Versus 3 years after adopting PACS. 1. The frequences of examination increased to 7,357.7 cases per month but the amount of film used decreased to 90%, from 42,774.4 to 4,181.88 after adopting the PACS. 2. 3 years after adopting PACS, monthly average amount of developing solution used decreased to 92% and the monthly average amount of fixing solution decreased to 86%. 3. Monthly average amount of developing solution used per film increased to 1.49 times and fixing solution increased as much as three times. 4. Monthly average wastewater for developing decreased to 88% and wastewater for fixing decreased up to 87%. 5. Monthly average wastewater for developing per film increased to 3.77 times and wastewater for fixing increased to 3.85 times. Although the amount of film used and the amount of developing and fixing wastewater affected by the reduction of the developing and fixing solution became less on the whole by introduction of PACS, they did not decrease proportionally. Moreover the amount of the developing and fixing solution used and the amount of developing and fixing wastewater per a film increased. That means the expectation for an environmental improvement differs from the actual condition.