• Title/Summary/Keyword: Radiation intensity

Search Result 978, Processing Time 0.026 seconds

Review Study on the Measurement Tools of Scoliosis: Mainly on Non-radiological Methods (척추측만증 평가 척도에 관한 문헌 고찰: 비방사선 방법을 중심으로)

  • Kim, Dong-Joo;Choi, Seong-Kyeong;Jo, Hyo-Rim;Ha, Yu-bin;Choi, Sung-Hwan;Park, Seo-Hyun;Lee, Seung Deok;Keum, Dong-Ho;Sung, Won-Suk;Kim, Eun-Jung
    • The Journal of Korean Medicine
    • /
    • v.42 no.1
    • /
    • pp.75-98
    • /
    • 2021
  • Objectives: The purpose of this study is to investigate the characteristics, validity, and reliability of non-radiological assessment tools of scoliosis that have been studied so far. Methods: Electronic databases including Pubmed, Cochrane Library, CNKI, Science On, RISS, OASIS were searched by keywords including 'scoliosis assessment', 'scoliosis screening', 'physical examination', 'functional measurement', 'photography', and 'smartphone'. Results: 32 articles using radiation-free assessments were identified from 1,011 records. The mostly used non-radiological methods were Surface topography, Scoliometer, Ultrasound, Digital Infrared Thermal Imaging, and Photography. The other methods were Gait analysis, 3D depth sensor imaging, and Low intensity electromagnetic scan. Conclusions: It was found that non-radiological assessment tools might reduce the number of radiographs taken in scoliosis patients. To increase the reliability and validity, further research on the measurement tools of scoliosis will be needed.

Current Radiopharmaceuticals for Positron Emission Tomography of Brain Tumors

  • Jung, Ji-hoon;Ahn, Byeong-Cheol
    • Brain Tumor Research and Treatment
    • /
    • v.6 no.2
    • /
    • pp.47-53
    • /
    • 2018
  • Brain tumors represent a diverse spectrum of histology, biology, prognosis, and treatment options. Although MRI remains the gold standard for morphological tumor characterization, positron emission tomography (PET) can play a critical role in evaluating disease status. This article focuses on the use of PET with radiolabeled glucose and amino acid analogs to aid in the diagnosis of tumors and differentiate between recurrent tumors and radiation necrosis. The most widely used tracer is $^{18}F$-fluorodeoxyglucose (FDG). Although the intensity of FDG uptake is clearly associated with tumor grade, the exact role of FDG PET imaging remains debatable. Additionally, high uptake of FDG in normal grey matter limits its use in some low-grade tumors that may not be visualized. Because of their potential to overcome the limitation of FDG PET of brain tumors, $^{11}C$-methionine and $^{18}F$-3,4-dihydroxyphenylalanine (FDOPA) have been proposed. Low accumulation of amino acid tracers in normal brains allows the detection of low-grade gliomas and facilitates more precise tumor delineation. These amino acid tracers have higher sensitivity and specificity for detecting brain tumors and differentiating recurrent tumors from post-therapeutic changes. FDG and amino acid tracers may be complementary, and both may be required for assessment of an individual patient. Additional tracers for brain tumor imaging are currently under development. Combinations of different tracers might provide more in-depth information about tumor characteristics, and current limitations may thus be overcome in the near future. PET with various tracers including FDG, $^{11}C$-methionine, and FDOPA has improved the management of patients with brain tumors. To evaluate the exact value of PET, however, additional prospective large sample studies are needed.

Effect of Flight Altitude on Minimal Infrared Signature of Combat Aircraft (고도 변화에 따른 전투기 적외선 신호 최소 조건 분석)

  • Nam, Juyeong;Chang, Injoong;Lee, Yongwoo;Kim, Jihyun;Cho, Hyung Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.6
    • /
    • pp.375-382
    • /
    • 2020
  • Owing to the rapid development of infrared guided weapon systems, the threat to aircraft survivability is constantly increasing, and research on infrared stealth technologies are being conducted to ensure aircraft survival. In this study, we analyze the minimum infrared signature of an aircraft according to its flight altitude by considering the characteristics of infrared guided missiles, which detect the contrast signature between the aircraft and background. We conducted computational fluid dynamics simulations for the convective coefficient, and heat transfer simulations were performed considering convection, conduction, and radiation for flight conditions. Thus, we obtained the surface temperature distribution of the aircraft and analyzed the aircraft infrared signature based on the flow characteristics around it. Furthermore, the optimum emissivity for the minimum infrared signature was derived, and the effect of the infrared signature was analyzed when this optimum emissivity was applied to the fuselage surface for each flight condition.

Research on 5G Base Station Evaluation Method through Electromagnetic Wave Intensity Prediction Model (전자파 강도 예측 모델을 통한 5G 기지국 평가 기법 연구)

  • Lee, Yang-Weon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.4
    • /
    • pp.558-564
    • /
    • 2021
  • With the recent introduction of 5G, electromagnetic radiation sources are spreading throughout life, so it is necessary to establish a citizen-centered electromagnetic safety management system. In particular, the beamforming method of the 5G antenna increases the power density measurement of electromagnetic waves by more than 10 times when the wireless base station is installed, so it is unreasonable to determine the safety by physical measurement. Therefore, it is necessary to determine the presence or absence of electromagnetic wave safety in daily life through a predictive method by calculation through systematic model analysis. In this paper, in order to check the possibility of a 5G wireless base station using an electromagnetic wave numerical analysis tool as a way to solve this problem, we compared the measured values of the actual base stations and the predicted values through the prediction model to compare the reliability. A method of constructing a real-time base station electromagnetic wave strength prediction evaluation system combined with software was also proposed.

The Error of the Method of Angular Sections of Microwave Sounding of Natural Environments in the System of Geoecological Monitoring

  • Fedoseeva, E.V.;Kuzichkin, O. R.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.47-53
    • /
    • 2021
  • The article deals with the problems of application of microwave methods in systems of geoecological monitoring of natural environments and resources of the agro-industrial complex. It is noted that the methods of microwave radiometry make it possible, by the power of the measured intrinsic radio-thermal radiation of the atmosphere, when solving inverse problems using empirical and semi-empirical models, to determine such parameters of the atmosphere as thermodynamic temperature, humidity, water content, moisture content, precipitation intensity, and the presence of different fractions of clouds.In addition to assessing the meteorological parameters of the atmosphere and the geophysical parameters of the underlying surface based on the data of microwave radiometric measurements, it is possible to promptly detect and study pollution of both the atmosphere and the earth's surface. A technique has been developed for the analysis of sources of measurement error and their numerical evaluation, because they have a significant effect on the accuracy of solving inverse problems of reconstructing the values of the physical parameters of the probed media.To analyze the degree of influence of the limited spatial selectivity of the antenna of the microwave radiometric system on the measurement error, we calculated the relative measurement error of the ratio of radio brightness contrasts in two angular directions. It has been determined that in the system of geoecological monitoring of natural environments, the effect of background noise is maximal with small changes in the radiobrightness temperature during angular scanning and high sensitivity of the receiving equipment.

Effects of Gamma Irradiation on Inhibition of Urease Activity and Fishy Smell in Mackerel (Scomber japonicus) during Refrigerated Storage

  • Jeong, So-Mi;Kim, Han-Ho;Ryu, Si-Hyeong;Kang, Woo-Sin;Lee, Ji-Eun;Kim, Su-Ryong;Lee, Ga-Hye;Xu, Xiaotong;Byun, Eui-baek;Ahn, Dong-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.6
    • /
    • pp.808-815
    • /
    • 2022
  • In this study, gamma-irradiated mackerel (Scomber japonicus) meat was stored in a refrigerator for 20 days to examine the physicochemical changes related to fishy smell. The effect of gamma irradiation on the inhibition of the activity of crude urease extracted from Vibrio parahaemolyticus was also evaluated. Increased levels of trimethylamine (TMA) and volatile basic nitrogen (VBN) content, which are the main components causing fishy smell, were significantly reduced by day 20 of storage after gamma irradiation, indicating that freshness was maintained during storage. The ammonia nitrogen contents of 3, 7, 10, and 20 kGy gamma-irradiated groups were significantly decreased by 6.5, 15.2, 17.4, and 23.9%, respectively, compared to non-irradiated groups on day 20 of storage. In addition, urease activity decreased in a gamma irradiation intensity-dependent manner. Volatile organic compounds (VOCs) were measured during the storage of gamma-irradiated mackerel meat. The contents of ethanol, 2-butanone, 3-methylbutanal, and trans-2-pentenal, which are known to cause off-flavors due to spoilage of fish, were significantly reduced by day 20 of storage. Therefore, gamma irradiation can be considered useful for inhibiting urease activity and reducing fishy smell during fish storage.

Characterization of X-ray Emitted in the Ion Implantation Process of Semiconductor Operations (반도체 제조 이온주입 공정의 이온 임플란타 장치에서 엑스레이 발생 특성)

  • Dong-Uk Park;Kyung Ehi Zoh;Soyeon Kim;Seunghee Lee;Eun Kyo Jeong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.439-446
    • /
    • 2023
  • Objectives: The aims of this study are to investigate how X-rays are emitted to surrounding parts during the ion implantation process, to analyze these emissions in relation to the properties of the ion implanter equipment, and to estimate the resulting exposure dose. Eight ion implanters equipped with high-voltage electrical systems were selected for this study. Methods: We monitored X-ray emissions at three locations outside of the ion implanters: the accelerator equipped with a high-voltage energy generator, the impurity ion source, and the beam line. We used a Personal Portable Dose Rate and Survey Meter to monitor real-time X-ray levels. The SX-2R probe, an X-ray Features probe designed for use with the RadiagemTM meter, was also utilized to monitor lower ranges of X-ray emissions. The counts per second (CPS) measured by the meter were estimated and then converted to a radiation dose (𝜇Sv/hr) based on a validated calibration graph between CPS and μGy/hr. Results: X-rays from seven ion implanters were consistently detected in high-voltage accelerator gaps, regardless of their proximity. X-rays specifically emanated from three ion implanters situated in the ion box gap and were also found in the beam lines of two ion implanters. The intensity of these X-rays did not show a clear pattern relative to the devices' age and electric properties, and notably, it decreased as the distance from the device increased. Conclusions: In conclusion, every gap, in which three components of the ion implanter devices were divided, was found to be insufficiently shielded against X-ray emissions, even though the exposure levels were not estimated to be higher than the threshold.

Environmental Control in the Plant Factory System Influences Year-Round Production of Allium hookeri Leaves (삼채(Allium hookeri) 잎 연중생산을 위한 식물공장 환경제어 효과)

  • Jeong-Wook Heo;Jeong-Hyun Baek;Sung-Hyen Lee;Min-Jeong Kim;Chang-Kee Shim
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.4
    • /
    • pp.279-285
    • /
    • 2023
  • The demand for the fresh leaf of hooker chive, which is mainly used as functional roots and contains dietary sulfur or saponin, is increasing, but the leaves are only harvested 3-4 times per year under conventional field conditions. A plant factory system with different light qualities or intensities was applied for year-round production of the fresh leaves. Hooker chive (Allium hookeri) roots were hydroponically cultured under the plant factory with a mixture of blue plus red LEDs (Light-Emitting Diodes) and fluorescent lights for 50 weeks. Maximum leaf growth was attained with the 1.5 dS/m EC in the culture medium under the plant factory. The average leaf and shoot numbers of hooker chive grown hydroponically under a mixture of 200 µmol/m2/s LEDs increased by 147% and 140%, respectively compared to those under 100 µmol/m2/s LEDs at the 10th harvest. The leaf length of hooker chive grown under the LEDs treatment with the lowest light intensity significantly increased by 27% compared with the natural light treatment at the 10th harvest. However, there was no significant difference in leaf pigmentation between natural and 200 µmol/m2/s LEDs treatments. Plant factory with the mixture LEDs of blue and red lights can be applied for year-round production of hooker chive fresh leaves to ensure a stable supply of leafy vegetable throughout the year.

Evaluation and Prediction of Post-Hepatectomy Liver Failure Using Imaging Techniques: Value of Gadoxetic Acid-Enhanced Magnetic Resonance Imaging

  • Keitaro Sofue;Ryuji Shimada;Eisuke Ueshima;Shohei Komatsu;Takeru Yamaguchi;Shinji Yabe;Yoshiko Ueno;Masatoshi Hori;Takamichi Murakami
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.24-32
    • /
    • 2024
  • Despite improvements in operative techniques and perioperative care, post-hepatectomy liver failure (PHLF) remains the most serious cause of morbidity and mortality after surgery, and several risk factors have been identified to predict PHLF. Although volumetric assessment using imaging contributes to surgical simulation by estimating the function of future liver remnants in predicting PHLF, liver function is assumed to be homogeneous throughout the liver. The combination of volumetric and functional analyses may be more useful for an accurate evaluation of liver function and prediction of PHLF than only volumetric analysis. Gadoxetic acid is a hepatocyte-specific magnetic resonance (MR) contrast agent that is taken up by hepatocytes via the OATP1 transporter after intravenous administration. Gadoxetic acid-enhanced MR imaging (MRI) offers information regarding both global and regional functions, leading to a more precise evaluation even in cases with heterogeneous liver function. Various indices, including signal intensity-based methods and MR relaxometry, have been proposed for the estimation of liver function and prediction of PHLF using gadoxetic acid-enhanced MRI. Recent developments in MR techniques, including high-resolution hepatobiliary phase images using deep learning image reconstruction and whole-liver T1 map acquisition, have enabled a more detailed and accurate estimation of liver function in gadoxetic acid-enhanced MRI.

Analysis on on the Leaf Growth and Changes of Photosynthetic Characterization by Leaf Position in 'Changhowon Hwangdo' Peach (복숭아 '장호원황도'의 엽위별 잎 발달과 광합성능의 변화에 대한 분석)

  • Yoon, Ik Koo;Yun, Seok Kyu;Jun, Ji Hae;Nam, Eun Young;Kwon, Jung Hyun;Bae, Hae Jin;Moon, Byung Woo;Kang, Hee Kyoung
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.361-365
    • /
    • 2013
  • To investigate factors determining peach fruit quality, chlorophyll content by leaf positions, chlorophyll content of foliated leaf, change of leaf area, and photosynthetic capacity were monitored. Photosynthetic rate in response to radiation intensity and $CO_2$ concentration, and change of sucrose content after shading treatment also were investigated. Chlorophyll content was similar in $5-12^{th}$ leaves after 10 days of foliation, while young $13-16^{th}$ leaves showed lower chlorophyll contents. Chlorophyll content was 2.56 ${\mu}g/cm^2$ on May $28^{th}$, just after foliation, and rapidly increased up to 6.35 ${\mu}g/cm^2$ on June $12^{th}$. After this point, chlorophyll content gradually increased during two months showing the highest value of 9.03 ${\mu}g/cm^2$ on August $14^{th}$. Leaf area was 27.1 $cm^2$ just after foliation and 37.7 $cm^2$ on $10^{th}$ day of foliation increasing 10.6 $cm^2$ during 10 days. Leaf area slowly increased by 3.9 $cm^2$ during next one month. Photosynthetic capacity increased rapidly until the $30^{th}$ day of foliation showing the highest capacity of 13.8 ${\mu}mol/m^{-2}/sec^{-1}$. After this point, photosynthetic capacity decreased sharply. Photosynthetic rate in response to radiation intensity increased rapidly until the PPFD reached to 600 ${\mu}mol/m^{-2}/sec^{-1}$ and increased gradually from 600 ${\mu}mol/m^{-2}/sec^{-1}$ to 1200 ${\mu}mol/m^{-2}/sec^{-1}$ of PPFD and stayed stable beyond this point. Photosynthetic rate in response to $CO_2$ concentration increased until 600 ppm of $CO_2$. At higher $CO_2$ concentration, photosynthetic rate stayed stable or decreased. Sucrose content in leaves was not significantly different between control and shading group until one hour of shading treatment while decreased in shading group after two hours of treatment.