• Title/Summary/Keyword: Radiation Usage

Search Result 106, Processing Time 0.02 seconds

A Comparision of the Radiation dose by Distance and the Direction according to a Tube Position of the C-arm Unit (C-arm의 Tube 위치에 따른 거리 및 방향별 피폭선량 비교)

  • Kim, Jin-Su;Woo, Bong-Cheol;Kim, Sung-Jin;Lee, Kwan-Sup;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • In operation room, the use of the C-arm unit is increasing. So, the radiation dose of the person who work in operation room was even more increased than before. Thus, this study is shown the measurement of expose dose and the way for decrease of the radiation dose by using the C-arm unit. The experiment was performed with the C-arm unit and used a phantom which is similar to tissue of the human body and fluoro-glass dosimeter for dose measurement. The expose dose were measured by the tube position(over tube, under tube) of the C-arm unit, distance(50, 100$\sim$200cm), direction(I, II, III, IV), runtime(1min, 3min), wearing of the apron. The radiation dose was decreased twice and three times at under tube rather than over tube. The I direction was measured 20$\sim$30% more than the others. The biggest expose dose is 50cm from center on distance. The expose dose is decreased to far from center. In case of Wearing of the apron, the radiation dose was decreased 60$\sim$90% by the distance. But there weren't change of the radiation dose by C-arm tube position. In present, by increasing the usage of the C-arm unit, the radiation dose is inevitable. So, this study recommends us to use the under tube of the C-arm unit. Also, Wearing of the apron is required for minimum of the radiation exposure.

  • PDF

Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation (CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구)

  • Kong, Hyo-Geum;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

Proposal for Comprehensive Quality Control of Heavy-Ion Medical Accelerator

  • Kim, Dong-wook;Shin, Dong-oh;Shin, Young-hoon;Heo, Hyun-do
    • Progress in Medical Physics
    • /
    • v.28 no.2
    • /
    • pp.67-75
    • /
    • 2017
  • Prior to the introduction of a medical apparatus based on heavy-ion medical accelerator in Korea, a study is needed on quality control in clinical operation for the safe and appropriate usage of the instrument. Data relevant for the study were obtained via information sharing sessions and visits by the Particle Therapy Co-Operative Group (PTCOG) and other related academic associations. Furthermore, investigative analysis of the European and Japanese performance evaluation guidelines for heavy ion, as well as research on relevant literature, were conducted. In addition, instrumental standards were analyzed through an investigation of the current usage status of the heavy-ion medical accelerator, and further analysis was conducted on the evaluation methods for the performance, safety, and significance of the instrument. Based on these analyses, regular quality control procedures for heavy-ion medical accelerators in hospitals and other institutes were extrapolated. It is hoped that the results of this study will facilitate hospitals that have introduced heavy-ion medical accelerators, or are considering the implementation of the instrument, in their understanding of the fundamental standards and capabilities of the treatment system, as well as in establishing and carrying out quality control procedures for clinical operations such that it will contribute to the safety of patients and the efficiency of medical practitioners.

Applicability of the Solar Irradiation Model in Preparation of Typical Weather Data Considering Domestic Climate Conditions (표준기상데이터 작성을 위한 국내 기후특성을 고려한 일사량 예측 모델 적합성 평가)

  • Shim, Ji-Soo;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.12
    • /
    • pp.467-476
    • /
    • 2016
  • As the energy saving issues become one of the important global agenda, the building simulation method is generally used to predict the inside energy usage to establish the power-saving strategies. To foretell an accurate energy usage of a building, proper and typical weather data are needed. For this reason, typical weather data are fundamental in building energy simulations and among the meteorological factors, the solar irradiation is the most important element. Therefore, preparing solar irradiation is a basic factor. However, there are few places where the horizontal solar radiation in domestic weather stations can be measured, so the prediction of the solar radiation is needed to arrive at typical weather data. In this paper, four solar radiation prediction models were analyzed in terms of their applicability for domestic weather conditions. A total of 12 regions were analyzed to compare the differences of solar irradiation between measurements and the prediction results. The applicability of the solar irradiation prediction model for a certain region was determined by the comparisons. The results were that the Zhang and Huang model showed the highest accuracy (Rad 0.87~0.80) in most of the analyzed regions. The Kasten model which utilizes a simple regression equation exhibited the second-highest accuracy. The Angstrom-Prescott model is easily used, also by employing a plain regression equation Lastly, the Winslow model which is known for predicting global horizontal solar irradiation at any climate regions uses a daily integration equation and showed a low accuracy regarding the domestic climate conditions in Korea.

Establishment of Database System for Radiation Oncology (방사선 종양 자료관리 시스템 구축)

  • Kim, Dae-Sup;Lee, Chang-Ju;Yoo, Soon-Mi;Kim, Jong-Min;Lee, Woo-Seok;Kang, Tae-Young;Back, Geum-Mun;Hong, Dong-Ki;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.91-102
    • /
    • 2008
  • Purpose: To enlarge the efficiency of operation and establish a constituency for development of new radiotherapy treatment through database which is established by arranging and indexing radiotherapy related affairs in well organized manner to have easy access by the user. Materials and Methods: In this study, Access program provided by Microsoft (MS Office Access) was used to operate the data base. The data of radiation oncology was distinguished by a business logs and maintenance expenditure in addition to stock management of accessories with respect to affairs and machinery management. Data for education and research was distinguished by education material for department duties, user manual and related thesis depending upon its property. Registration of data was designed to have input form according to its subject and the information of data was designed to be inspected by making a report. Number of machine failure in addition to its respective repairing hours from machine maintenance expenditure in a period of January 2008 to April 2009 was analyzed with the result of initial system usage and one year after the usage. Results: Radiation oncology database system was accomplished by distinguishing work related and research related criteria. The data are arranged and collected according to its subjects and classes, and can be accessed by searching the required data through referring the descriptions from each criteria. 32.3% of total average time was reduced on analyzing repairing hours by acquiring number of machine failure in addition to its type in a period of January 2008 to April 2009 through machine maintenance expenditure. Conclusion: On distinguishing and indexing present and past data upon its subjective criteria through the database system for radiation oncology, the use of information can be easily accessed to enlarge the efficiency of operation, and in further, can be a constituency for improvement of work process by acquiring various information required for new radiotherapy treatment in real time.

  • PDF

Proton Therapy for Head and Neck Cancer: Current Clinical Applications and Future Direction (두경부암의 양성자치료: 현재의 임상 적용 및 발전 방향)

  • Oh, Dongryul
    • Korean Journal of Head & Neck Oncology
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Intensity-modulated radiation therapy (IMRT) using X-rays is a standard technique implemented for treating head and neck cancer (HN C). Compared to 3D conformal RT, IMRT can significantly reduce the radiation dose to surrounding normal tissues by using a highly conformal dose to the tumor. Proton therapy is a type of RT that uses positively charged particles named protons. Proton therapy has a unique energy deposit (i.e., Bragg peak) and greater biological effectiveness than that of therapy using X-rays. These inherent properties of proton therapy make the technique advantageous for HNC treatment. Recently, advanced techniques such as intensity-modulated proton therapy have further decreased the dose to normal organs with a higher conformal dose to the tumor. The usage of proton therapy for HNC is becoming widespread as the number of operational proton therapy centers has increased worldwide. This paper aims to present the current clinical evidence of proton therapy utility to HNC clinicians through a literature review. It also discusses the challenges associated with proton therapy and prospective development of the technique.

Determination of dosimetric dependence for effective atomic number of LDR brachytherapy seed capsule by Monte Carlo simulation

  • Berkay Camgoz;Dilara Tarim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2734-2741
    • /
    • 2023
  • Brachytherapy is a special case of radiotherapy. It should be arranged according to some principles in medical radiation applications and radiation physics. The primary principle is to use as low as reasonably achievable dose in all ionizing radiation applications for diagnostic and therapeutic treatments. Dosimetric distributions are dependent on radioactive source properties and radiation-matter interactions in an absorber medium such as phantom or tissue. In this consideration, the geometrical structure and material of the seed capsule, which surrounds a radioactive material, are directly responsible for isodose profiles and dosimetric functions. In this study, the radiometric properties of capsule material were investigated on dose distribution in a water phantom by changing its nuclear properties using the EGSnrc Monte Carlo (MC) simulation code. Effective atomic numbers of hypothetic mixtures were calculated by using different elements with several fractions for capsule material. Model 6711 brachytherapy seed was modeled by EGSnrc/Dosrcnrc Code and dosimetric functions were calculated. As a result, dosimetric parameters of hypothetic sources have been acquired in large-scale atomic number. Dosimetric deviations between the data of hypothetic seeds and the original one were analyzed. Unit dose (Gy/Particle) distributions belonging to different types of material in seed capsule have remarkably differed from the original capsule's data. Capsule type is major variable to manage the expected dose profile and isodose distribution around a seed. This study shows us systematically varied scale of material type (cross section or effective atomic number dependent) offers selective material usage in production of seed capsules for the expected isodose profile of a specific source.

The IRPA Young Generation Network: Activity Report from the Middle of 2018 to the Beginning of 2021

  • Andresz, Sylvain;Sakoda, Akihiro;Ha, Wi-Ho;Kabrt, Franz;Kono, Takahiko;Munoz, Marina Saez;Nusrat, Omar;Papp, Cinthia;Qiu, Rui;Bryant, Pete
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.143-150
    • /
    • 2021
  • Since its establishment in 2018, the Young Generation Network (YGN) has been dedicated, with support of the International Radiation Protection Association (IRPA), to a variety of activities to promote communication, collaboration and professional development of students and young professionals in the area of radiation protection and its allied fields. This article reports our recent activities from the middle of 2018 to the beginning of 2021, with highlights on some important events: "Joint JHPS-SRP-KARP Workshop of Young Generation Network" (December 2019 in Japan); contribution to "Nuclear Energy Agency Workshop on Optimization: Rethinking the Art of Reasonable" (January 2020 in Portugal); survey on the impact of coronavirus disease 2019 (COVID-19) on radiation protection among IRPA YGN members (March 2020); and contribution to IRPA15 (15th International Congress of the IRPA; January-February 2021, online). The discussion and insight obtained from each activity are also summarized. The IRPA YGN will aim to achieve its on-going activities and continue to follow the ways paved in the Strategic Agenda and despite the challenges raised by the COVID-19 pandemic. Namely, running an international survey (for example, on the usage of social media in radiation protection, and on the long-term consequences of the COVID-19 pandemic), engaging national YGNs, extending the network, finding new relationships with networks with an interest in the young generation and participation in (remote) events will be aspired for.

Estimated Exposure Dose and Usage of Radiological Examination of the National Health Screening (국가건강검진의 방사선검사 이용량 및 피폭선량 추정)

  • Gil, Jong Won;Park, Jong Hyock;Park, Min Hui;Park, Chan Young;Kim, So Young;Shin, Dong Wook;Kim, Won Dong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.142-149
    • /
    • 2014
  • Korea conducts a national health screening program to improve and check-up on public health and in recent years, the screening usage has been increased. Given the increased screening usage for radiographic exams, this study predicts the frequency of using radiographic exams and the exposure dose. This study estimates the usage of radiographic exams by isolating radiographic exams from the 2011 analysis of the national health insurance corporation, and estimates the public exposure dose by applying each procedure's dose table from UNSCEAR 2008. As a result of the analysis, in the 2011 National Health Screening, the average exposure dose per person is assumed to be 0.57 mSv, and depending on the type of screening program from the radiographic exam, an examinee could be exposed to between 0.2 mSv and 11.081 mSv. The frequency of using radiographic exposure was found to be 16,005,914 and the exposure dose was 6,311.76 person-Sv. The most frequent exam is the Chest X-ray, which was performed 1,070,567 (69.17%), and the UGI has the highest exposure dose at 5,217.94 person-Sv (82.67%). The outcome is categorized based on gender and age, excluding those under 39 years old. In all age groups, the screening usage and exposure dose are higher in females than in males. In particular, females between 50 and 54 years old have the highest screening usage (1,674,787, 10.5%) and exposure dose (701.59 person-Sv, 11.1%). As UGI accounts for 82.76% of procedures, except when done for medical purposes, if the government supports a voluntary UGI exam (which includes the UGI exam in the National Screening Program) or abolishes it completely, as seen overseas, the cost-effectiveness and validity of the UGI exam, as well as the exposure dose from the National Screening Program will all decrease significantly.

Esophageal Cancer, Gastric Cancer and the use of Pesticides in the Southwestern of Turkey

  • Yildirim, Mustafa;Kaya, Vildan;Yildiz, Mustafa;Demirpence, Ozlem;Gunduz, Seyda;Dilli, Utku Donem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2821-2823
    • /
    • 2014
  • Background: Esophageal and gastric cancer generally have a poor prognosis and may share common risk factors. It has been demonstrated that the pesticide usage may contribute to development of many cancer types. In this study, the relation between amount of pesticides used in agriculture and esophageal and gastric cancer incidence was researched. Materials and Methods: Findings from the data bank of the Ministry of Health Provincial Health Directorate Cancer Records Center between the years of 1998-2010 were used. All patients who were diagnosed with gastric and esophageal cancer histopathologically were included. Data for annual pesticide usage were obtained from Provincial Agriculture Directorate for the same time period. Statistical analysis was performed using the Spearman test. Results: One thousand eight hundred and ninety-six patients were involved in the study, 1,233 males (65%) and 663 females (35%), 230 with esophageal cancer (12.1%) and 1,666 with gastric cancer (87.9%). No statistically significant relation was apparent between pesticide amount used and esophageal cancer (p: 0.87). Conclusions: In our study, there was no relationship between pesticide usage and esophageal or gastric cancer. However, the time between pesticide usage and cancer development was not known, qualifying the comparison.