References
- Kubota N, Suzuki M, Furusawa Y, et al. A comparison of biological effects of modulated carbon-ions and fast neutrons in human osteosarcoma cells. Int J Radiat Oncol. 1995;33:135-41. https://doi.org/10.1016/0360-3016(95)00029-X
- Ishizaki A, Ishii K, Kanematsu N, et al. Development of an irradiation method with lateral modulation of SOBP width using a cone-type filter for carbon ion beams. Med Phys. 2009;36:2222-7. https://doi.org/10.1118/1.3130021
- Tessonnier T, Boehlen TT, Cerutti F, et al. Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg ion beam therapy center. Phys Med Biol. 2017.
- Mar t isikova M, Jakel O. Dosimet ric proper t ies of Gafchromic(R) EBT films in medical carbon ion beams. Phys Med Biol. 2010;55:5557-67. https://doi.org/10.1088/0031-9155/55/18/019
- Tessonnier T, Mairani A, Brons S, Haberer T, Debus J, Parodi K. Experimental dosimetric comparison of 1H, 4He, 12C and 16O scanned ion beams. Phys Med Biol. 2017;62:3958-82. https://doi.org/10.1088/1361-6560/aa6516
- Torikoshi M, Minohara S, Kanematsu N, Komori M, et al. Irradiation system for HIMAC. J Radiat Res. 2007;48:Suppl A, A15-25. https://doi.org/10.1269/jrr.48.A15
- Pavlovic M. Oblique gantry: An alternative for heavy-ion cancer therapy, Strahlentherapie und Onkologie: Organ der Deutschen Rontgengesellschaft 1999;175:Suppl 2, 24-6. https://doi.org/10.1007/BF03038881
- Gueulette J, Wambersie A. comparison of the methods of specifying carbon ion doses at NIRS and GSI. J Radiat Res. 2007;48:Suppl A, A97-A102. https://doi.org/10.1269/jrr.48.A97
- Lu HM, Kooy H. Optimization of current modulation function for proton spread-out Bragg peak fields. Med Phys. 2006;33:1281-7. https://doi.org/10.1118/1.2188072
- Yeboah C, Sandison GA, Chvetsov AV. Intensity and energy modulated radiotherapy with proton beams: Variables affecting optimal prostate plan. Med Phys. 2002;29:176-189. https://doi.org/10.1118/1.1445409
- Moreno JO, Pullia MG, Priano C, Lante V, Necchi MM, Savazzi S. Study of the magnets used for a mobile isocenter carbon ion gantry. J Radiat Res. 2013;54: Suppl 1, i147-54. https://doi.org/10.1093/jrr/rrt041
- Blattmann H. Beam delivery systems for charged particles. Radiat Environ Biophys. 1992;31:219-31. https://doi.org/10.1007/BF01214829
- Chen CC, Chang C, Moyers MF, Gao M, Mah D. Technical note: Spot characteristic stability for proton pencil beam scanning. Med Phys. 2016;43:777-82. https://doi.org/10.1118/1.4939663
- Heeg P, Eickhoff H, Haberer T. Conception of heavy ion beam therapy at Heidelberg University (HICAT), Zeitschrift fur Medizinische Physik. 2004;14:17-24. https://doi.org/10.1078/0939-3889-00197
- Cao Y, Li JQ, Sun LT, et al. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy. Rev Sci Instrum. 2014;85:02A960. https://doi.org/10.1063/1.4852335
- Muramatsu M, Hojo S, Iwata Y, et al. Development of a compact ECR ion source for various ion production. Rev Sci Instrum. 2016;87:02C110. https://doi.org/10.1063/1.4935221
- Souda H, Yamada S, Kanai T, et al. Operation status of the electron cyclotron resonance ion source at Gunma University. Rev Sci Instrum. 2014;85:02A934. https://doi.org/10.1063/1.4833922
- Tinschert K, Iannucci R, Lang R. Electron cyclotron resonance ion sources in use for heavy ion cancer therapy. Rev Sci Instrum. 2008;79:02C505.
- Winkelmann T, Cee R, Haberer T, et al. Electron cyclotron resonance ion source experience at the Heidelberg Ion Beam Therapy Center. Rev Sci Instrum. 2008;79:02A331.
- Schulz-Ertner D, Nikoghosyan A, Hof H, et al. Carbon ion radiotherapy of skull base chondrosarcomas. Int J Radiat Oncol. 2007;67:171-7. https://doi.org/10.1016/j.ijrobp.2006.08.027
- Ferlay J, Steliarova-Foucher E, Lortet-Tieulent J, et al. Cancer incidence and mortality patterns in Europe: eEstimates for 40 countries in 2012. Eur J Cancer. 2013;49:1374-403. https://doi.org/10.1016/j.ejca.2012.12.027
- Kamada T, Tsujii H, Blakely EA, J. et al. Carbon ion radiotherapy in Japan: An assessment of 20 years of clinical experience. Lancet Oncology. 2015;16:e93-e100. https://doi.org/10.1016/S1470-2045(14)70412-7
- Tsujii H, Mizoe JE, Kamada T, et al. Overview of clinical experiences on carbon ion radiotherapy at NIRS. Radiother Oncol. 2004;73 Suppl 2,S41-9.
- Kamada T. Clinical evidence of particle beam therapy (carbon). Int J Radiat Oncol. 2012;17:85-8.
- Oh CM, Won YJ, Jung KW, et al. Community of populationbased regional cancer, cancer statistics in Korea: Incidence, mortality, survival, and prevalence in 2013. Cancer Research and Treatment: Official Journal of Korean Cancer Association 2016;48:436-50. https://doi.org/10.4143/crt.2016.089
- Kamo K, Sobue T. Cancer statistics digest: Mortality trend of prostate, breast, uterus, ovary, bladder and kidney and other urinary tract cancer in Japan by birth cohort. Japanese Journal of Clinical Oncology 2004;34:561-3. https://doi.org/10.1093/jjco/hyh100
- Saika S, Sobue T. [Cancer statistics in the world], Gan to kagaku ryoho. Cancer Chemother 2013;40:2475-80.
- Hata M, Tokuuye K, Sugahara S, et al. Proton beam therapy for aged patients with hepatocellular carcinoma. Int J Radiat Oncol. 2007;69:805-12. https://doi.org/10.1016/j.ijrobp.2007.04.016
- Hata M, Tokuuye K, Kagei K, et al. Hypofractionated highdose proton beam therapy for stage I non-small-cell lung cancer: preliminary results of a phase I/II clinical study. Int J Radiat Oncol. 2007;68:786-93. https://doi.org/10.1016/j.ijrobp.2006.12.063
- Yonai S. [Guideline for the handling and management of radioactive materials in ion beam radiotherapy facility], Igaku butsuri: Nihon Igaku Butsuri Gakkai kikanshi. Japanese Journal of Medical Physics 2012;32:81-5.
- Sheehan M, Timlin C, Peach K, et al. Position statement on ethics, equipoise and research on charged particle radiation therapy. J Med Ethics. 2014;40:572-5. https://doi.org/10.1136/medethics-2012-101290
- Durante M, Orecchia R, Loeff ler JS. Charged-particle therapy in cancer: Clinical uses and future perspectives. Nat Rev Clin Oncol. 2017.
- Ui-Jung Hwang YGL, Kim DW, Shin DO, et al. Study on staffing of medical physicist in the field of radiation therapy. Progress in Medical Physics 2012;23:10.
- Klein EE. A grid to facilitate physics staffing justification. J Appl Clin Med Phys. 2009;11:2987.
- Van Loon R. The role and contribution of a medical physicist in a radiology department. Journal belge de radiologie 1997;80:12-6.
- Mills MD. Analysis and practical use: The Abt Study of medical physicist work values for radiation oncology physics services, round II. Journal of the American College of Radiology 2005;2:782-9. https://doi.org/10.1016/j.jacr.2005.02.009
- Kayama T, Nemoto K. [Current Status and Future Prospects of Charged Particle Radiation Therapy]. No shinkei geka: Neurological Surgery 44; 2016:449-54.