Dosimetric Comparison of 6 MV Flattening Filter Free and 6 MV Stereotactic Radiosurgery Beam Using 4 mm Conical Collimator for Trigeminal Neuralgia Radiosurgery

  • Mhatre, Vaibhav R;Chadha, Pranav;Kumar, Abhaya P;Talapatra, Kaustav
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.107-113
    • /
    • 2018
  • Background: The purpose of our study was to compare the dosimetric advantages of Flattening filter free (FFF) beams for trigeminal neuralgia patients using 4 mm conical collimators over previously treated patients with 6 MV SRS beam. Materials and Methods: A retrospective study was conducted for 5 TN patients who had been previously treated at our institution using frame-based, LINAC-based stereotactic radiosurgery (SRS) on Novalis Tx using 6 MV SRS beam were replanned on 6X FFF beams on Edge Linear accelerator with same beam angles and dose constraints using 4 mm conical collimator. The total number of monitor units along with the beam on time was compared for both Edge and Novalis Tx by redelivering the plans in QA mode of LINAC to compare the delivery efficiency. Plan quality was evaluated by homogeneity index (HI) and Paddick gradient index (GI) for each plan. We also analyzed the doses to brainstem and organ at risks (OARs). Results and Discussion: A 28% beam-on time reduction was achieved using 6X FFF when compared with 6X SRS beam of Novalis Tx. A sharp dose fall off with gradient index value of $3.4{\pm}0.27$ for 4 mm Varian conical collimator while $4.17{\pm}0.20$ with BrainLab cone. Among the 5 patients treated with a 4 mm cone, average maximum brainstem dose was 10.24 Gy for Edge using 6X FFF and 14.28 Gy for Novalis Tx using 6X SRS beam. Conclusion: The use of FFF beams improves delivery efficiency and conical collimator reduces dose to OAR's for TN radiosurgery. Further investigation is warranted with larger sample patient data.

광섬유 센서를 이용한 EED 전자파 방사 위해도 분석 (Analysis of Electromagnetic Radiation Hazard for Electro-explosive Device Using Fiber Optic Sensor)

  • 김응조;윤기은;윤태훈;김재창
    • 한국전자파학회논문지
    • /
    • 제9권6호
    • /
    • pp.725-734
    • /
    • 1998
  • When the EED is exposed to the high power radiation, it is possible to verify systems survivability through measuring the induced current of EED. The usual method of performing a system level test is to replace the EED's with modified units from which the explosive charge has been removed and replaced with the fiber optic sensor. The thermal transient test was performed to obtain the temperature vs current characteristic curve for optical sensor installed in EED. The currents measured when the system is exposed to a known EME are compared to the proposed specfication about the EED and a decision is made on whether system is safe or not.

  • PDF

스네이크 라인 선열 안테나 (The Snaked-line Array Antenna)

  • 양인응;이상설;오승엽
    • 대한전자공학회논문지
    • /
    • 제10권5호
    • /
    • pp.21-30
    • /
    • 1973
  • X-Band용으로 높은 이득을 갖는 스네이크라인 선열안테나의 감쇠상수와 복사모양에 관하여 논한다. 등가적으로 폭사저항에 상당한 감쇠상수는 대략 스네이크라인의 굴곡크기를 뜻하는 Sin θa의 자승함수로 변화한다. 선열의 지향성은 스네이크라인의 수와 각 라인의 고유수에 의해서 결정된다.

  • PDF

뇌 확산강조 자기공명영상에 대한 정량적, 성적 평가: 1.5 T와 3.0 T 기기 비교 (Quantitative and Qualitative Evaluation of Brain Diffusion Weighted Magnetic Resonance Imaging: Comparision with 1.5 T and 3.0 T Units)

  • 구은회;동경래
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.227-230
    • /
    • 2016
  • DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging. In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5T and 3.0T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5T.

보건의료 빅데이터를 활용한 의료장비 및 방사선사 인력 현황 연구 : 2020-2021년 자료를 기준으로 (A Study on the Status of Medical Equipment and Radiological Technologists using Big Data for Health Care: Based on Data for 2020-2021)

  • 장현철
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.667-673
    • /
    • 2021
  • 4차 산업혁명 시대에 진입하면서 방사선 의료 기술 개발의 혁신 및 고도화에 따라 방사선사의 업무 범위는 더욱더 확대될 것으로 판단된다. 본 연구에서는 의료장비 및 방사선사 인력 현황을 파악하여 4차 산업혁명시대 변화에 있어 방사선 의료기술분야 인재 양성 계획, 진로 및 취업 상담에 기초자료를 제공하고자 하였다. 보건의료 빅데이터를 이용하여 2020년부터 2분기 자료와 2021년 2분기 자료를 통해 분석하였다. 연구결과 2020년 대비 2021년 종별 의료장비 현황 비교 결과 C-Arm X-선 검사 장비가 6,638대로 5.83% 가장 높게 증가하였으며, 다음 순으로 MRI 검사 장비 1,811대 5.29%, 혈관조영 검사 장비 725대 5.22%, 일반 X-선 검사 장비 21,557대 3.99%, CT 검사 장비 2,136대 3.03%, 유방 검사 장비 3,425대 3.00% 증가하였다. 2020년 대비 2021년 전체 방사선사 인력 현황 비교 결과 29,038명으로 2.73% 증가하였다. 지역별 방사선사 인력 현황 비교 결과 경기 지역에서 5.96%로 가장 높게 증가하였으며, 다음순으로 강원 지역 5.66%, 충남지역 3.81% 증가하였다. 의료장비 및 방사선사 인력이 증가하는 상황에서 대학에서는 4차 산업혁명 시대의료 방사선 기술영역에서 적용할 수 있는 맞춤형 인공지능 및 빅데이터에 관한 이해 및 활용과 관련된 교과목 개발을 통한 전문적 지식과 실무역량을 갖춘 방사선사 양성이 필요하며, 협회 차원에서는 새로운 일자리 창출 및 취업 향상을 위한 적극적인 정책이 필요할 것으로 생각된다.

Flavonoids of Rosa roxburghii Tratt Act as Radioprotectors

  • Xu, Ping;Zhang, Wen-Bo;Cai, Xin-Hua;Lu, Dan-Dan;He, Xiao-Yang;Qiu, Pei-Yong;Wu, Jiao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권19호
    • /
    • pp.8171-8175
    • /
    • 2014
  • Background: To study the radioprotective effects of flavonoids from Rosa roxburghii Tratt (FRT). Materials and Methods: The radioprotective effects of FRT were investigated by examining cell viability, 30-day survival of mice and the number of colony-forming units in spleen (CFU-S) after total-body 60Co irradiation. Results: The survival rates of irradiated cells gradually increased with increasing concentrations of FRT. The survival rate was the highest at 87% with a concentration of $30{\mu}g/mL$. Pretreatment with FRT was needed to realize its radioprotective activity in mice at the dose of 60 mg/kg. With the increasing doses of 30 mg/kg, 60 mg/kg and 120 mg/kg, the numbers of CFU-S increased, and were significantly different compared with the control group. Conclusions: Pretreatment with FRT prior to irradiation resulted in significantly higher cell survival at 24 h after 5 Gy radiation, increased 30-day survival in mice after exposure to a potentially lethal dose of 8 Gy, and resulted in a higher number of CFU-S in mice after exposure to a dose of 6 Gy. These results collectively indicate that FRT is an effective radioprotective agent.

속중성자선의 선량분포에 관한 연구 (Fast Neutron Beam Dosimetry)

  • 이효남;지영훈;지광수;이동한
    • 대한방사선치료학회지
    • /
    • 제9권1호
    • /
    • pp.71-81
    • /
    • 1997
  • I. Objective and Importance of the Project We have been using MC-50 cyclotron and NT-50 neutron therapy machine for treating cancer patients since 1986 at Korea Cancer Center Hospital. It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine (Task Group 18), European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induce the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. II. Scope and Contents of the Project For establishing a unique technique of measurement and inventing a standard method of measurement of fast neutron beam, 1. to grasp the physical characteristics of neutron therapy machine 2. to study the principles for measrement of fast neutron beam 3. to get the dose distribution (dose rate, percent-depth dose, flatness etc) throught the actual measurement 4. to compare our data with those being cited world-widely.

  • PDF

Determination of defect depth in industrial radiography imaging using MCNP code and SuperMC software

  • Khorshidi, Abdollah;Khosrowpour, Behzad;Hosseini, S. Hamed
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1597-1601
    • /
    • 2020
  • Background: Non-destructive evaluation of defects in metals or composites specimens is a regular method in radiographic imaging. The maintenance examination of metallic structures is a relatively difficult effort that requires robust techniques for use in industrial environments. Methods: In this research, iron plate, lead marker and tungsten defect with a 0.1 cm radius in spherical shape were separately simulated by MCNP code and SuperMC software. By 192Ir radiation source, two exposures were considered to determine the depth of the actual defined defect in the software. Also by the code, displacement shift of the defect were computed derived from changing the source location along the x- or y-axis. Results: The computed defect depth was identified 0.71 cm in comparison to the actual one with accuracy of 13%. Meanwhile, the defect position was recognized by disorder and reduction in obtained gamma flux. The flux amount along the x-axis was approximately 0.5E+11 units greater than the y-axis. Conclusion: This study provides a method for detecting the depth and position of the defect in a particular sample by combining code and software simulators.

RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰 (Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS.)

  • 문언철
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

이동형 치과 X선 발생장치의 공간선량 분포 (Spatial Dose Distribution from Portable Hand-Held Dental X-Ray Equipment)

  • 한경순;안성민
    • 치위생과학회지
    • /
    • 제15권3호
    • /
    • pp.254-258
    • /
    • 2015
  • 치과병의원에서 사용하고 있는 이동형 치과 X선 발생장치를 이용하여 두경부 마네킹에 X선을 조사할 때 주변의 공간선량을 측정하고, 동일한 방법으로 고정형 X선 발생장치에 적용하여 측정된 공간선량을 상호 비교하며, 더불어 기기 및 위치별 공간선량을 비교 분석한 결과는 다음과 같다. 이동형 X선 발생장치의 평균 공간선량은 $37.51{\mu}Sv$로 고정형 X선 발생장치의 $10.77{\mu}Sv$보다 매우 높았다(p<0.001). 이동형 X선 발생장치의 기기별 공간선량은 $17.77{\mu}Sv$부터 $68.90{\mu}Sv$까지 큰 차이를 나타냈다(p<0.05). 위치별로는 직전 위치가 $54.14{\mu}Sv$로 가장 높았고, 직우 위치가 $13.60{\mu}Sv$로 가장 낮았으며, 직좌와 직후 위치는 $42.12{\mu}Sv$, $40.18{\mu}Sv$로 유사하였다(p<0.01). 이상의 결과를 통해 이동용 치과 X선 발생장치는 이동 불가능한 환자만을 대상으로 제한적으로 시행하여야 하며, 반드시 환자와 술자 모두 납 방어복을 착용하여 방사선 피폭을 최소화해야 할 것이다.