• 제목/요약/키워드: ROOFTOP OF A BUILDING

검색결과 120건 처리시간 0.022초

Millimeter-wave diffraction-loss model based on over-rooftop propagation measurements

  • Kim, Kyung-Won;Kim, Myung-Don;Lee, Juyul;Park, Jae-Joon;Yoon, Young Keun;Chong, Young Jun
    • ETRI Journal
    • /
    • 제42권6호
    • /
    • pp.827-836
    • /
    • 2020
  • Measuring the diffraction loss for high frequencies, long distances, and large diffraction angles is difficult because of the high path loss. Securing a well-controlled environment to avoid reflected waves also makes long-range diffraction measurements challenging. Thus, the prediction of diffraction loss at millimeter-wave frequency bands relies on theoretical models, such as the knife-edge diffraction (KED) and geometrical theory of diffraction (GTD) models; however, these models produce different diffraction losses even under the same environment. Our observations revealed that the KED model underestimated the diffraction loss in a large Fresnel-Kirchhoff diffraction parameter environment. We collected power-delay profiles when millimeter waves propagated over a building rooftop at millimeter-wave frequency bands and calculated the diffraction losses from the measurements while eliminating the multipath effects. Comparisons between the measurements and the KED and GTD diffraction-loss models are shown. Based on the measurements, an approximation model is also proposed that provides a simple method for calculating the diffraction loss using geometrical parameters.

통계적 방법을 이용한 복층 저소음포장의 소음저감효과 분석 (An Analysis on Noise Reduction Effects of Two-Layer Low Noise Pavements using Statistical Methods)

  • 이상혁;한대석;유인균;이수형
    • 한국도로학회논문집
    • /
    • 제19권6호
    • /
    • pp.1-11
    • /
    • 2017
  • PURPOSES : The purpose of this study is to compare noise reduction quantities between before/after two-layer low noise pavement implementation using equivalent noise level analysis and to analyze the noise reduction effects of the two layer low noise pavement with a statistical method such as the Anderson-Darling Test. METHODS : In order to compare and to analyze noise reduction effects between before/after two-layer low noise pavement implementation, data acquisition as noise levels on a roadside and an apartment rooftop was conducted in the study area. The equivalent noise level was estimated in order to compare noise reduction quantities and the Anderson-Darling Test was carried out for estimating noise reduction effects of the two-layer low noise pavement. RESULTS : The equivalent noise levels of before/after two-layer low noise pavement implementation for the roadside during the daytime are 65.355 dB and 63.520 dB and during the nighttime are 62.463 dB and 59.088 dB. The equivalent noise levels for the apartment rooftop during daytime are 57.301 dB and 59.088 dB and during the nighttime are 54.616 dB and 52.464 dB. Also two-layer low noise pavement decreased the noise reduction effects estimated with the statistical method as the Anderson-Darling test for the roadside during the daytime by around 66.68% and decreased noise reduction effects on the roadside during the nighttime by 0.70%. Moreover it reduced noise reduction effects in the apartment rooftop during the daytime and nighttime by 0% and 96.32%, respectively. CONCLUSIONS : Based on the result of this study, two-layer low noise pavement can positively affect noise reduction during both the daytime and nighttime according to the results of estimating the equivalent noise levels and the Anderson-Darling test.

옥상부 외단열 및 외방수 공법 제안에 관한 기초연구 (A study on the External Insulation and Waterproof Method of Rooftop)

  • Jang, Dae-Hee
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.137-138
    • /
    • 2019
  • To overcome the limitation in relation to thermal insulator's selection and installation method that is suitable for exterior insulation and waterproof construction methods, a production basis of thermal insulators of which manufacturing knowhow is held by companies was ensured and future-oriented construction methods to adopt new materials were applied. Performance verification was conducted through performance and mock-up tests of thermal transmittance on the cross sections where the flexible insulators were applied based on the improved prototype and performance data were obtained. To overcome the biggest drawbacks (walking feeling and damage etc.) in the exterior insulation and waterproof construction method, inserting a protective layer between thermal insulator and water-proof layer was proposed, and polypropylene corrugated cardboards.

  • PDF

고해상도 위성영상으로부터 건물 정위 레이어 자동추출 (Automated Extraction of Orthorectified Building Layer from High-Resolution Satellite Images)

  • 김승희;김태정
    • 대한원격탐사학회지
    • /
    • 제39권3호
    • /
    • pp.339-353
    • /
    • 2023
  • 고해상도 위성영상의 제공이 증가함에 따라 위성영상의 위치정확도 향상이 요구되고 있다. 이를 위해 기복변위를 제거하고 인공지물의 정위가 수립된 정사영상 생성의 중요성이 높아지고 있다. 본 논문에서는 기존에 구축된 건물 높이 데이터베이스를 이용하여 원본 위성영상에서의 건물 옥상면과 건물포함영역을 자동으로 추출하였다. 이후 추출된 건물 옥상면을 정위치 편집하여 건물 정위 레이어(layer)를 생성하였다. 추출된 건물포함영역을 이용하여 위성영상에서 건물영역을 공백 처리하여 비건물 정위 레이어를 생성하였다. 이후, 실감정사 건물레이어와 실감정사 비건물레이어를 중첩하여 최종 정사영상을 제작하였다. 본 연구에서 제안한 방법은 KOMPSAT-3 및 KOMPSAT-3A 위성영상을 이용해 실험하였으며, 실험 결과를 수치지형도와 중첩하여 검증을 수행하였다. 실험결과 건물 정위 레이어는 0.4 m의 위치 오차를 가지는 것으로 나타났다. 제안 방법을 통해 도심지역에 대한 자동 실감정사영상 생성의 가능성을 확인하였다.

Building Integrated Photovoltaics: Technical and Aesthetic Prospects

  • Polgampola Chamani Madara;Hasnain Yousuf;Muhammad Aleem Zahid;Suresh Kumar Dhungel;Youngkuk Kim;Junsin Yi
    • 한국전기전자재료학회논문지
    • /
    • 제37권2호
    • /
    • pp.154-163
    • /
    • 2024
  • The energy demand in the world is expected to exceed 740 million TJ by 2040 and our dependence on fossil fuels needs to be switched to sustainable and renewable energy sources like solar energy. Building Integrated Photovoltaic (BIPV) is one of the best approaches to extracting solar energy. There are more than 200 BIPV products in the market currently but when it comes to integrating these products into the technical aspects such as buildings' structural integrity, thermal, daylight retainment and aesthetic prospects to be considered. The share of BIPV integration potential of different building types in the world of residential, agricultural, industrial, commercial and other buildings account for 66%, 4.8%, 8.1%, 19.9%, and 1.2% accordingly. Many solar technologies developed to achieve architectural requirements, but the main problem is the trade-off between efficiency and aesthetic appeal, which is less than 10% in coloured and transparent solar modules. This paper discusses the different applications of solar photovoltaics (PV) in building architecture, technical requirements, and different module technologies. The article provides a comprehensive guide for researchers and designers working on the development of BIPV integrations.

옥상 및 인공지반 방근공사에 적용되는 TPO시트의 재생 소재 적용에 따른 인장성능 변화 연구 (Study on tensile performance change by recycled materials of TPO sheet applied to rooftop and artificial ground Rootproofings)

  • 김선도;김진성
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.103-104
    • /
    • 2018
  • Recently, in addition to greening of roof and artificial soil, Rootproofing to prevent damage to the waterproof layer and structures by roots is recognized as an important task. Therefore, various related products and construction methods have been developed and applied in the field. However, in the case of synthetic polymer-based sheets most commonly used in domestic construction sites, Most are produced using 100% new materials that are not suitable for green trends such as resource conservation and environmental protection. Therefore, in this study, we developed TPO sheet using recycled material, which is a technology that can secure eco-friendliness by utilizing recycled resources. As a result of the evaluation of tensile performance of the TPO sheet according to the recycled material content, The tensile strength of the specimens with the recycled content of 50 ~ 70% was the highest, The elongation rate of the specimen with the recycled content of 30 ~ 40% was the best.

  • PDF

방수시트의 평행접합방법에 따른 인장성능 평가연구 (A Study on the Evaluation of Tensile Performance According to Pareral Jointing Methods of the Sheet Membrane Waterproofing System)

  • 이정윤;오미현;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술대회지
    • /
    • pp.39-44
    • /
    • 2004
  • A heat and room temperature construction method of asphalt have been mainly applying to rooftop waterproofing in concrete structure, and the rest construction method are sheet, membrane and mortar waterproofing construction method. In particular, joint method in sheet waterproof method is as overlap joint which on being reinforced with fiber and tape, have been applying for job site to mechanical fix using protection disk and anchorage and metal ironwork on the end of sheet. These construction method cause cutting off joint of sheet as behavior of structure according to repairs of sheet itself and thermal conduct, outdoor air environment. In conclusion, we analyzed and examined the application of various sheets and piece ashes about superior 'I' joint which divide from one and the other sheet and progressed about joint construction method of fixing method for overlap.

  • PDF

건축물 안전관리 실태분석을 통한 중점안전관리 대상 및 요소 설정에 관한 연구 (A Study on the Critical Safety Management Buildings and factors by Analyzing the Actual State of Building Safety Management)

  • 김은희
    • 대한건축학회논문집:계획계
    • /
    • 제35권4호
    • /
    • pp.37-44
    • /
    • 2019
  • According to the statistical surveys and studies, insufficient maintenance in the use of existing buildings caused fire and collapse accidents. In this respect, I analyzed the data managed by the current building maintenance and inspection system to find out the actual state of safety management and proposed two significant results. First, regarding the state of the buildings, the safety management status of the small-sized ones, where 20 years or more passed after construction, is the worst and a priority improvement plan is required. Second, there are eight deeply concerning factors for the fire incidents and collapse accidents of buildings. In the order of high risk, these factors are structural strength (seismic design), exterior wall finishing material, basement floor, interior finishing materials, other evacuation facilities, corridors stairs entrances, rooftop, fire partition. We need to have more special designs and management plans regarding high-risk factors as a system to prevent accidents in the building.

옥상 노출방수용 PVC 방수시트의 방위별(남, 북) 장기옥외폭로에 따른 물성 변화 연구 (A Study on Changes of Physical Properties of Rooftop Exposed Waterproofing PVC Sheet based on Longterm Outdoor Exposure Testing with Bearings (North, South))

  • 안기원;문유석;김천학;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.147-148
    • /
    • 2015
  • Exposed type waterproofing PVC sheets installed on structure rooftops are subject to changes in physical properties after longterm exposure to sunlight. Particularly when consideration the rotational movement of sunlight over the day through the course of the sun rising from the east and setting in the west, in the case of flat roofs the amount of UV ray the the surface of the PVC waterproofing sheet receives may be even throughout, but in cases of slanted rooftops the sunlight exposure may be uneven across the surface. In this regard, this study examines the effect uneven sunlight exposure on the exposed type waterproofing PVC sheets installed on slanted rooftops.

  • PDF

방송사 건물의 친환경 설계 적용 요소에 대한 에너지 소비 분석 연구 (The Energy Consumption Analysis for the Eco-friendly Design Application Factors of a Broadcasting Building)

  • 김배영;윤혜경
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.41-48
    • /
    • 2018
  • This study is expected to provide some basic data on how to apply more economical and efficient eco-friendly factors to reduce the carbon emissions. It has been scrutinized and analyzed the environmental factors of passive eco-friendly elements along with active eco-friendly elements as more efficient factors for energy conservation based on the case of a newly constructed broadcasting building with the green building certification in Sangam-dong DMC area. The first analysis was the energy consumption trends in Korea and the necessity of energy saving. Secondly, it was examined the energy consumption in the current status of the broadcasting building. Thirdly, it was looked into the correlation between the eco-friendly design application factors applied to the broadcasting building and the energy consumption types. As a result of the analysis, the application of fan and feed pump inverter along with ventilation system of waste heat recovery ventilation system were more meaningful in accordance with the economic feasibility of broadcasting buildings rather than economical effect of passive elements such as rooftop garden, reinforcement of building insulation. Also, the application of lighting control had the economical feasibility. Therefore, when it is intended to change the green building certification energy related evaluation items of the similar broadcasting building types, it is necessary to change the direction of adding weight to the more economical active element items in the future.