• Title/Summary/Keyword: RF test

Search Result 697, Processing Time 0.031 seconds

A Characteristic Analysis of the RF Sensitivity for Electro-explosive Device (전기 기폭 장치 RF 민감도 특성 분석)

  • 김응조;최태인;윤태훈;김재창
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.927-934
    • /
    • 1999
  • A measuring system was integrated for the testing of live EED with continuous wave RF stimulus at low frequency range(1~250 MHz) and pulsed RF stimulus at high frequency range(8~10 GHz). The test system, set-up method and test procedure for the RF sensitivity of EED are described in this paper. The Bruceton method is applied to obtain distribution statistics such as mean firing level, standard deviation of the distribution and confidence levels for various applied firing signals.

  • PDF

Test-bed Design for the Evaluation of Wireless Communication System on Small Launch Vehicle (소형 발사체 무선 통신시스템 검증을 위한 테스트 베드 설계)

  • Lee, Dae-Hyun;Oh, TaeckKeun;Park, Dong-Hwa;Lee, Hong-Ki;Park, Dong-Hyun;Song, Ho-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.311-318
    • /
    • 2018
  • In this paper, test-bed for the evaluation of wireless communication system on a small launch vehicle is proposed. The proposed test-bed consists of antenna test-coupler, RF attenuators, and RF switch modules. The antenna test-coupler isolates antennas for each band and transmits / receives wireless signals. The RF attenuator and switch are used for path selection of testing signal path. In design and measurement result of the antenna test-coupler, the antenna test-coupler has shielding effect higher than 39.3, 47.1, 56.1 dB at UHF-, S-, X-band. Through testing on small launch vehicle wireless communication system, we were able to successfully transmit and receive data between each test system and launch vehicle with antenna path switching.

Vacuum Characteristics of KSTAR ICRF Antenna during RF Operation (고주파 인가시의 KSTAR ICRF 안테나의 진공특성)

  • Bae, Young-Dug;Kwak, Jong-Gu;Hong, Bong-Geon
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.314-324
    • /
    • 2006
  • The vacuum characteristics of the KSTAR ICRF antenna were experimentally investigated. The fabricated antenna was installed in the RF Test Chamber(RFTC) which has a vacuum system with an effective pumping speed of 1015 l/s. The time variations of RFTC pressure, total gas load and ultimate pressure were measured before the RF test. RF conditioning effect was studied by repeating RF pulses at low power level. A time variation of the RFTC pressure was measured during a RF power was applied to the antenna. Threshold pressure at which a RF breakdown occurs was investigated. Whenever the pressure was higher than $10^{-4}$ mbar, the RF breakdown occurred. During a long pulse testing, the temperature of the antenna and RFTC pressure were measured to investigate long pulse limitation of the maximum available voltage without any cooling, which were compared with testing results with a water cooling of the antenna.

A Study on Performance Requirement of I/Q Impairments for RF Implementation in W-CDMA User Equipment (W-CDMA 사용자장치 RF 구현을 위한 I/Q 열화성능요구규격 연구)

  • Lee, Il-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.148-154
    • /
    • 2005
  • This paper deals with performance degradations caused by RF I/Q impairments such as amplitude mismatch and phase mismatch in W-CDMA user equipment which uses QPSK(Quadrature Phase Shift Keying) modulation. The impacts of I/Q impairments on the BER(Bit Error Rate) are analyzed by using the variations of adjacent symbol distance. The BER versus amplitude mismatch and phase mismatch with QPSK constellation is reviewed through Matlab simulation. Performance degradation produced by RF I/Q impairments is measured with the implemented RF transceiver and modulation/demodulation test equipments through EVM(Error Vector Magnitude). The minimum performance requirements of amplitude mismatch and phase mismatch in W-CDMA user equipment are presented from the point of hardware implementation and the test method of the impairments is also included.

A Characteristics of RF Sensitivity for a Firing Fuse (기폭용 퓨즈의 RF 감도 특성)

  • 간종만;권준혁
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.573-578
    • /
    • 2004
  • EED consists of bridgewire, explosive charge, lead pins and metal case. If a firing signal is injected to EED, the explosive charge in EED is initiated by heating of bridgewire. Electromagnetic waves radiated from high power transmitters or radars can also cause unexpected firing of EED. Therefore, EMC design and test requirements for EED in military specifications are established and applied. This report describes the characteristics of RF sensitivity fur a firing fuse which is used fur EMC test instead of a real EED installed in aircraft. RF firing level of the fuse was predicted using transmission line(TL) theory. n sensitivity and RF sensitivity specified in military specifications were measured.

Investigation of Relation between EFTB Test and RF Conductive Immunity Test Using BER and Baseband Signal

  • Kuwabara, Nobuo;Irie, Yasuhiro;Hirasawa, Norihito;Akiyama, Yoshiharu
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.274-281
    • /
    • 2011
  • High-speed telecommunication systems are influenced by electromagnetic environments because they need a wide bandwidth to transmit signals. Immunity tests of telecommunication equipment are effective for improving its immunity to electromagnetic environments. However, immunity tests are expensive to carry out because there are several different tests. The correlation among the tests should therefore be examined in order to reduce the kinds of tests that are necessary. This paper investigates the correlation between the electrical fast transient/burst (EFTB) test and the radio frequency (RF) conductive immunity test. Imitation equipment was constructed with a balun, and a baseband signal was transmitted from the associated equipment to the imitation equipment. Then, disturbances were applied to the equipment, and the telecommunication quality was evaluated by using the bit error rate (BER). The results from the EFTB test indicated that the BER was less than $6{\times}10^{-5}$ and the value was independent of the peak value. The results from the RF conductive immunity test indicated that the BER was affected by the longitudinal conversion loss (LCL).

Testing and Self Calibration of RF Circuit using MEMS Switches

  • Kannan, Sukeshwar;Kim, Bruce;Noh, Seok-Ho;Park, Se-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.882-885
    • /
    • 2011
  • This paper presents testing and self-calibration of RF circuits using MEMS switches to identify process-related defects and out of specification circuits. We have developed a novel multi-tone dither test technique where the test stimulus is generated by modulating the RF carrier signal with a multi-tone signal generated using an Arbitrary Waveform Generator (AWG) with additive white Gaussian noise. This test stimulus is provided as input to the RF circuit and peak-to-average ratio (PAR) is measured at the output. For a faulty circuit, a significant difference is observed in the value of PAR as compared to a fault-free circuit. Simulation is performed for various circuit conditions such as fault-free as well as fault-induced and their corresponding PARs are stored in the look-up table. This testing and self-calibration technique is exhaustive and efficient for present-day communication systems.

  • PDF

Discharge Characteristics of Large-Area High-Power RF Ion Source for Neutral Beam Injector on Fusion Devices

  • Chang, Doo-Hee;Park, Min;Jeong, Seung Ho;Kim, Tae-Seong;Lee, Kwang Won;In, Sang Ryul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.241.1-241.1
    • /
    • 2014
  • The large-area high-power radio-frequency (RF) driven ion sources based on the negative hydrogen (deuterium) ion beam extraction are the major components of neutral beam injection (NBI) systems in future large-scale fusion devices such as an ITER and DEMO. Positive hydrogen (deuterium) RF ion sources were the major components of the second NBI system on ASDEX-U tokamak. A test large-area high-power RF ion source (LAHP-RaFIS) has been developed for steady-state operation at the Korea Atomic Energy Research Institute (KAERI) to extract the positive ions, which can be used for the NBI heating and current drive systems in the present fusion devices, and to extract the negative ions for negative ion-based plasma heating and for future fusion devices such as a Fusion Neutron Source and Korea-DEMO. The test RF ion source consists of a driver region, including a helical antenna and a discharge chamber, and an expansion region. RF power can be transferred at up to 10 kW with a fixed frequency of 2 MHz through an optimized RF matching system. An actively water-cooled Faraday shield is located inside the driver region of the ion source for the stable and steady-state operations of RF discharge. The characteristics and uniformities of the plasma parameter in the RF ion source were measured at the lowest area of the expansion bucket using two RF-compensated electrostatic probes along the direction of the short- and long-dimensions of the expansion region. The plasma parameters in the expansion region were characterized by the variation of loaded RF power (voltage) and filling gas pressure.

  • PDF

Predicting the CPT-based pile set-up parameters using HHO-RF and PSO-RF hybrid models

  • Yun Dawei;Zheng Bing;Gu Bingbing;Gao Xibo;Behnaz Razzaghzadeh
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.673-686
    • /
    • 2023
  • Determining the properties of pile from cone penetration test (CPT) is costly, and need several in-situ tests. At the present study, two novel hybrid learning models, namely PSO-RF and HHO-RF, which are an amalgamation of random forest (RF) with particle swarm optimization (PSO) and Harris hawks optimization (HHO) were developed and applied to predict the pile set-up parameter "A" from CPT for the design aim of the projects. To forecast the "A," CPT data along were collected from different sites in Louisiana, where the selected variables as input were plasticity index (PI), undrained shear strength (Su), and over consolidation ratio (OCR). Results show that both PSO-RF and HHO-RF models have acceptable performance in predicting the set-up parameter "A," with R2 larger than 0.9094, representing the admissible correlation between observed and predicted values. HHO-RF has better proficiency than the PSO-RF model, with R2 and RMSE equal to 0.9328 and 0.0292 for the training phase and 0.9729 and 0.024 for testing data, respectively. Moreover, PI and OBJ indices are considered, in which the HHO-RF model has lower results which leads to outperforming this hybrid algorithm with respect to PSO-RF for predicting the pile set-up parameter "A," consequently being specified as the proposed model. Therefore, the results demonstrate the ability of the HHO algorithm in determining the optimal value of RF hyperparameters than PSO.

The Chemical Screening of Caryophyllaceae Plants (석죽과식물(石竹科植物)의 성분검색(成分檢索))

  • Chung, Dong-Kyu;Kim, Tae-Hee;Lee, Yong-Ran
    • Korean Journal of Pharmacognosy
    • /
    • v.9 no.2
    • /
    • pp.83-88
    • /
    • 1978
  • From phytochemical screening of the seven species of Caryophyllaceae, that is, one species of Melandrium, and Dianthus and Pseudostellaria, two species of Stellaria and Cerastium the following compounds were identified. 1) aldehyde, sugars, other reducing compounds and glycosides from the above mentioned seven species of Caryophyllaceae were identified by thin layer chromatography method and comparison of Rf values with the standard substances. 2) Saponins, steroids and terpenoids showed positive reaction with the Froth testing in all of seven plants. Five species of plant showed positive reaction with Liebermann-Buchard test. 3) Flavonoid and polyphenolic compounds were identified by the spots in TLC-test and chlorogenic acid showed the same Rf values with the standard substances. 4) The spots of alkaloid were shown at Rf=0.68 (Stellaria aquatica) and at Rf=0.71 (Pseudostellaria palibiniana) and at Rf=0.70, and 0.44 (Dianthus sinensis).

  • PDF