The Analysis of the LCL Set-up Parameters for Satellite Power Distribution (위성전원분배를 위한 LCL 동작 파라미터 설정분석)

  • Lim, Seong-Bin;Jeon, Hyun-Jin;Kim, Kyung-Soo;Kim, Tae-Youn
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.56-64
    • /
    • 2011
  • In this paper, the characteristics of LCL set-up parameters for the satellite load distribution are analyzed under the electrical system environment, implemented the LCL circuits and evaluated the performance and its behaviour. Recently, it is implemented the load distribution circuit by latching current limiter(LCL) rather than conventional fuse and relay for the protection of the satellite power system from a fault load. The LCL circuit is composed of the electrical components, not mechanical parts with the fuse and relay. When detected the over current on a fault load, it is activated to maintain the trip-off level for set-up time and then cut-off the load power by the active control. It is more flexible and provided a chance to reuse of the load in case of temporarily event, but the fuse and relay can't be used again after activating due to the physical disconnection. However, for implementation of LCL circuit, it should be carefully considered the behavior of the LCL circuit under the worst electrical system environment and applied it to define the set-up parameters related with over-current inhibition.

UPnP Protocol Extension for Contents Sharing among Digital Home Networks (디지털 홈 네트워크 간 콘텐츠 공유를 위한 UPnP 확장 기법)

  • 이현룡;김종원
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10c
    • /
    • pp.151-153
    • /
    • 2004
  • 홈 네트워크의 보급과 P2P 기반의 커뮤니티가 활성화되는 추세로 미루어 볼 때 가까운 장래에 사용자들은 홈 네트워크에 기반한 커뮤니티를 형성하길 원할 것으로 예측되며, 이를 지원하기 위해 표준에 근간한 접근 방법이 제시되어야 한다. 따라서 본 논문에서는 홈 네트워킹을 위한 대표적인 프로토콜인 UPRP 에 기반하여 홈 네트워크간의 콘텐츠 공유를 지원하는 방안을 모색한다. UPnP포럼에서 정의하는 표준 기능에 UPnP프로토콜의 특성을 이용한 RelayModule을 구현하고 추가함으로 UPnP에 기반한 홈 네트워크 사이의 연결을 지원하고 더 나아가 디지털 콘텐츠 공유를 지원한다.

  • PDF

Method and implementation for reducing standby power consumption in intermediate capacity power supply with Power Line Communication (전력선통신기능 적용 중.대용량 전원공급장치의 대기전력 절감방법 및 구현)

  • Son, Do-Sun;Kim, Ki-Hyun;Kim, Sang-Cheol;Jeon, Eui-Seok;Lee, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1947-1948
    • /
    • 2008
  • This paper presents the implementation of Power Line Communication(PLC) module which can reduce standby-power consumption. The suggested PLC module consists of PLC modem, coupling circuit, ZCP(Zero-Cross Point) Circuit and main SMPS control relay. The test results under power line communication test-bed used home appliance show the 77% saving of standby-power.

  • PDF

A Study on Efficient Interface between Point Machine and Interlocking System for High Speed and Conventional Railroad (고속 및 일반철도용 연동장치와 선로전환기간 효율적 인터페이스 방안 연구)

  • Lee, Jae-Ho;Kang, Shin-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1747-1751
    • /
    • 2014
  • Interlocking system along with point machine for efficient route control secures safety of train operation by interchanging information each other. However, various types of interlocking system and point machine operating on bender specific interface bring obstacles to effective maintenance and safety. In this paper, we have investigated on interface methods to suggest standard interface module applicable to various operating system

Design and Implementation of Large Capacity Cable Checking System using an I/O Buffer Method (입.출력 버퍼방식을 이용한 대용량 케이블 점검 시스템 설계 및 구현)

  • 양종원
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.103-115
    • /
    • 2002
  • This paper describes the results on the design and implementation of large capacity cable checking system using I/O buffer method. The I/O buffer module which has feedback loops with input and output buffers is designed with logic gate in the VME board and controlled by MPC860 microprocessor. So this system can check a lot of cable at the same time with less size and less processing time than that of relay matrix method with the A/D converter. The size of the I/O buffer module can be variable according to the number of cable. And any type of cable can be checked even if the pin assignment of cable is changed.

A Development of Web-based Safety Evaluation System of Motor-Operated-Valve in Nuclear Power Plant (웹기반 원전 동력구동밸브 안정성 평가 시스템 개발)

  • Bae, J.H.;Lee, K.N.;Kim, W.M.;Park, S.K.;Lee, D.H.;Kim, J.C.;Hong, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.903-908
    • /
    • 2001
  • A web-based client/server program, MOVIDIK(Motor-Operated-Valve Integrated Database Information of KEPCO) has been developed to perform a design basis safety evaluation for a motor-operated-valve(MOV) in the nuclear power plant. The MOVIDIK consists of seven analysis modules and one administrative module. The analysis module calculates a differential pressure on the valve disk, thrust/torque acting at a valve stem, maximum allowable stress, thermal-overload-relay selection, voltage degradation, actuator output and margin. In addition, the administrative module manages user information, approval system and code information. MOVIDIK controls a huge amount of evaluation data and piles up the safety information of safety-related MOV. The MOVIDIK will improve the efficiency of safety evaluation work and standardize the analysis process for the MOV.

  • PDF

A Study on the Development of Signal Matching Module for Heterogeneous Network in WCDMA (WCDMA 이동통신망에서 이종간 네트워크 신호 정합 모듈 개발에 관한 연구)

  • Yoo, DongJoo;Kim, Keunsik
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.85-91
    • /
    • 2017
  • This paper concerns the design of a matching module system enabling the RF signal to be harmonized between the new base stations (RRH) and the repeater in the same frequency band of the asynchronous transfer network. This matching system controls the RF Gain Control of the module while monitoring the quality of the quality. Additionally, the RF environment has been adapted accordingly to adjust the RF Gain Control to match the receiver characteristics of the relay. As a result of this study, we improved the quality of the interface between the new base stations and existing relays.

Control And Monitoring Of Air Circuit Breaker Using Digital Protective Relay (디지털보호계전기를 이용한 기중차단기 제어 및 모니터링)

  • Lee, Sung-Hwan;Park, Sang-Bae;Ahn, Ihn-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.240-242
    • /
    • 2001
  • On this research, to catch up with international trend on the power system utilities move to be digitalized and move to network is certainly technological on the global business world, to compete with advanced foreign countries in the range of transmit and distribute power system and to take possession of first market share within country, we talked over a monitoring system to diagnose, monitor ACB(Air Circuit Breaker) only which is operated on the low level voltage Power plant. AMS(ACB Monitoring System) have be configured with several modules such as engine module which acquire engineering data from HICM360/860(Communication Control Units) and analyze and save it, database module which restore data and can be inquired, system monitoring view module which reflects fields information within a second, realtime trend window, historical trend window, reports as daily and yearly. In a near future, AMS must upgrade GUI to have easy to handle and have to have a field test to fit on real plants, so it will have faith in system reliability as it can apply power plant monitoring system in wide.

  • PDF

The Design and Implementation of DELAY Module for Real-Time Broadcast Delay (실시간 방송 지연을 위한 DELAY 모듈의 설계 및 구현)

  • Ahn, Heuihak;Gu, Jayeong;Lee, Daesik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.3
    • /
    • pp.45-53
    • /
    • 2019
  • Moving image sharing technology has developed various servers and programs for personal broadcasting. In this paper, we propose the method of transmitting the multiple moving image, including the output channel of external streaming server. It also implements and tests multiple real-time broadcast channel automatic transmission systems that assign multiple output channels to automatic output channels. As a result of the experiment, it is easy to allocate moving image to broadcast channels that are output through the external streaming server's output channels regardless of the size of the streaming server, enabling the management of efficient output channels at the time of transmission of multiple moving image. The moving image can be provided through streaming method regardless of the type of moving image from the moving image provider terminal, and the moving image transmission can be controlled in various ways, including adding and changing channels for which the moving image is sent, and sending delayed to the moving image.

IoT based Cleaner Control System using Smart Devices

  • Ye Ho Shin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.5
    • /
    • pp.1-8
    • /
    • 2023
  • In this paper, we implement a control system for an IoT-based backpack type vacuum cleaner using a smart device such as a smart phone or smart watch. The implementation system consists of control module produces, control module programming, and smart device programming. The control module is made of Arduino Nano, HM-10 BLE(Bluetooth Low Energy) module and relays as basic parts. The smart device exchanges signals with the control module via bi-directional BLE communication, which allows it to control the start/stop of the vacuum cleaner. Backpack type vacuum cleaners are effective for cleaning high places that require the use of ladders. However, it is often necessary to take off the backpack type cleaner to start/stop it. The IoT-based vacuum cleaner control system implemented in this paper fundamentally solves the problem by allowing users to control the start/stop of the vacuum cleaner without taking it off.