• Title/Summary/Keyword: R2R system

Search Result 6,932, Processing Time 0.037 seconds

Study on the Performance Improvement for an Automobile Air Conditioning System Using Alternative Refrigerant R1234yf (대체냉매 R1234yf를 적용한 자동차용 에어컨 시스템의 성능 향상에 관한 연구)

  • Cho, Honghyun;Lee, Hoseong;Park, Chasik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.4
    • /
    • pp.201-207
    • /
    • 2013
  • The performance of automobile air conditioning systems of R1234yf was evaluated and compared with that of R134a. In particular, the performance evaluation was carried out by installing an internal heat exchanger in order to improve the performance of the system used in R1234yf. A performance comparison between the R1234yf and R134a for automotive air conditioning revealed that the cooling capacity and COP of the 1234yf system without the IHX decreased by up to 7% and 4.5%, respectively, but those with the IHX decreased by up to 1.8% and 2.9%, respectively.

A Study on the Refrigerant Characteristics of the Organic Rankine Cycle Power System Using the Waste Heat of the Main Propulsion Engine (선박 주 추진 엔진폐열을 이용하는 고온도차발전시스템의 냉매특성에 관한 연구)

  • Song, Young-uk;Jee, Jae-hoon;Park, Sang-kyun;Oh, Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.839-845
    • /
    • 2021
  • In this study, it shows the efficiency of each refrigerant through simulation method for ORC (Organic Rankine Cycle) power generation that converts waste heat discarded by ship exhaust into electricity for the purpose of reducing CO2 emission and increasing ship waste heat recovery. by Simulation was performed with waste heat from the exhaust gas which is relatively high temperature and cooling sea water which is relatively low temperature from ships. As a result of the sea water cooling ORC power generating system, efficiency of the working fluid with R717 is highest as a 2.86 % and the next working fluid is R152a, R134a, R143a and R125a.

COHEN-MACAULAY MODULES OVER NOETHERIAN LOCAL RINGS

  • Bahmanpour, Kamal
    • Bulletin of the Korean Mathematical Society
    • /
    • v.51 no.2
    • /
    • pp.373-386
    • /
    • 2014
  • Let (R,m) be a commutative Noetherian local ring. In this paper we show that a finitely generated R-module M of dimension d is Cohen-Macaulay if and only if there exists a proper ideal I of R such that depth($M/I^nM$) = d for $n{\gg}0$. Also we show that, if dim(R) = d and $I_1{\subset}\;{\cdots}\;{\subset}I_n$ is a chain of ideals of R such that $R/I_k$ is maximal Cohen-Macaulay for all k, then $n{\leq}{\ell}_R(R/(a_1,{\ldots},a_d)R)$ for every system of parameters $a1,{\ldots},a_d$ of R. Also, in the case where dim(R) = 2, we prove that the ideal transform $D_m(R/p)$ is minimax balanced big Cohen-Macaulay, for every $p{\in}Assh_R$(R), and we give some equivalent conditions for this ideal transform being maximal Cohen-Macaulay.

oneM2M Standard based Low Altitude Drone/UAV Traffic Management System (oneM2M 표준 기반 저고도 무인기 관리 및 운영시스템)

  • Ahn, Il-Yeop;Park, Jong-Hong;Sung, Nak-Myoung;Kim, Jaeho;Choi, Sung-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.301-307
    • /
    • 2018
  • Unmanned Aerial Vehicles (i.e., drone) are gaining a lot of interest from a wide range of application domains such as infrastructure monitoring and parcel delivery service. In those service scenarios, multiple UAVs are involved and should be reliably operated by so-called UAV management system. For that, we propose oneM2M standard based UAV management and control system which is specifically targeted at traffic management of low-altitude UAVs. In this paper, we include oneM2M platform architecture and its implementation for UAV management system in conjunction with UAV interworking procedure.

A Study on the Factors of Job Satisfaction of the Dietitians Working in Hospitals (병원영양사의 직무만족요인에 대한 조사연구)

  • 이현숙
    • Journal of Nutrition and Health
    • /
    • v.29 no.6
    • /
    • pp.651-660
    • /
    • 1996
  • The purpose of this study was to examine and analyze the degrees and the influence factors of job satisfaction of dietitians working in hospitals in relation to performance of duty in their works and to provide effective management of hospital dietitians for high quality health and food service in hospital. The questionaire was prepared with reference to the previous studies on job satisfaction of dietitians working in hospitals throughout the nation. 201 dietitians in the country were surveyed. The period of research was from January 20 to February 28, 1995. The results are as follows. 1) In regard to the degree of job satisfaction of hospital dietitians, they showed the highest degree of job satisfaction in the relationships with fellow dietitians followed by worth and self-confidence, aptitude and interests, relationships with cooks, job stability, degree of recognition of the dietitians competence, supervision of the superiors, degree of application of professional knowledge, work load, wage level, degree of recognition of the importance of duty, cooperative relationships with load, wage level, degree of recognition of the importance of duty, cooperative relationships with doctors, degree of performance of clinical work, the number of dietitians, the prromotion system, and welfare system in that order. On the other hand, they showed the highest dissatisfaction with food service facilities. 2) The influence factors on job satisfaction are as follows. (1) Wage factor : Shorter weekday working hours and higher bonuses make greaster job satisfaction (R2=0.3115). (2) Working condition factor : Larger number of monthly holidays(R2=0.5142), shorter weekday working hours(R2=0.1077), longer previous food service experience and computer utilization (R2=0.1432) make greater job satisfaction. (3) Welfare factor : Welfare system (R2=0.4132) and promotion system (R2=0.1624) have to do with computer utilization. Job stability has to do with marital status and computer utilization (R2=0.1165). consequently, those married dietitians who use computers show higher job satisfaction. (4) Human relationship factor : Smaller mumber of patients receiving food makes greater job satisfaction (R2=0.1334). (5) Superivision factor : Shorter weekday working hours and larger number of monthly holidays make greater job satisfaction (R2=0.1709). (6) Achievement factor : Marriage, larger number of dietitians(R2=9.2293), age, larger number of monthly holiday, higher monthly wages and computer utiliazation (R2=0.1088) make greater job satisfaction. (7) Speciality factor : Marriage, longer current hospital tenure, higher position and working in seoul(R2=0.1142) make higher job satisfaction. (8) Job inclination factor : working in general hospitals rather than in oriental hispitals, working in seoul(R2=0.1776) and better bonuses(R2=0.1078)make greater job satisfaction. As a result, the following is suggested for the job satisfaction of hospital dietitions on the basis of this study : hospital dietitians can achieve miximum job satisfaction through smooth relationships with coworkers, and the responsible managers should improve welfare and working conditions for the job satisfaction of hospital dietitians.

  • PDF

A Development of 2MVA Battery Energy Storage System (2MVA급 배터리 에너지 저장시스템 개발)

  • Kim, Soo-Hong;Kim, Tae-Hyeong;Kim, Yun-Hyun;In, Dong-Seok;Kwon, Byung-Ki;Choi, Chang-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.174-181
    • /
    • 2012
  • Energy storage system connected to the grid has two functions such as the surplus power of a grid is stored in batteries or the energy stored in batteries will supply to the grid when the grid needs. The battery energy storage system consist of power condition system (PCS) for power supply and battery conditioning system (BCS). Lithium-ion batteries are mainly used. In this paper, the battery energy storage system connected to the grid described. The configuration of the 2MVA class power control system using water cooling and battery system are presented. And control method for the system and the output filter design method are proposed. Experimental verification of the proposed system is provided with 2MVA PCS and 500kWh BCS.

Sensitivity enhancement of H2 gas sensor using PbS quantum dots (황화납 양자점 감지막을 통해 감도가 개선된 수소센서)

  • Kim, Sae-Wan;Kim, Na-Ri;Kwon, Jin-Beom;Kim, Jae Keon;Jung, Dong Geon;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.388-393
    • /
    • 2020
  • In this study, a PbS quantum dots (QDs)-based H2 gas sensor with a Pd electrode was proposed. QDs have a size of several nanometers, and they can exhibit a high surface area when forming a thin film. In particular, the NH2 present in the ligand of PbS QDs and H2 gas are combined to form NH3+, subsequently the electrical characteristics of the QDs change. In addition to the resistance change owing to the reaction between Pd and H2 gas, the resistance change owing to the reaction between the NH2 of PbS QDs and H2 gas increases the current signal at the sensor output, which can produce a high output signal for the same concentration of H2 gas. Using the XRD and absorbance properties, the synthesis and particle size of the synthesized PbS QDs were analyzed. Using PbS QDs, the sensitivity was significantly improved by 44%. In addition, the proposed H2 gas sensor has high selectivity because it has low reactivity with heterogeneous gases such as C2H2, CO2, and CH4.

Performance Characteristics of R744 OTEC Power Cycle with Operation Parameters (운전조건에 따른 R744용 해양온도차 발전 사이클의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.580-585
    • /
    • 2012
  • In this paper, the cycle performance analysis for condensation and evaporation capacity, total work and efficiency of ocean thermal energy conversion power system using R744 ($CO_2$) is presented to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include superheating and subcooling degree, evaporation and condensation temperature, pump and turbine efficiency. The main results were summarized as follows : The evaporation capacity of R744 increases with superheating and subcooling degree, but decreases with the increasing condensation temperature. The total work increases with superheating and subcooling degree of R744, but decreases with the increasing evaporating temperature. And, the efficiency increases with subcooling and superheating degree, but decreases with the increasing condensation temperature. Therefore, superheating and subcooling degree, evaporation and condensation temperature and pump and turbine efficiency of R744 OTEC power system have an effect on the evaporation and condensation capacity, total work and efficiency of this system. With a thorough grasp of these effect, it is necessary to design the OTEC power cycle using R744.

Quantitative Relationship between Body Composition and Muscular Strength Measured with the Biodex System 3 (Biodex System3을 사용한 근력측정과 체조성의 양적조건과의 관련성)

  • Lee, Sang-Un;Kim, Yong-Kwon;Sato, Kouki
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.208-215
    • /
    • 2003
  • This study measured body composition and muscular strength, to examine their relationship, using the Bioelectrical Impedance (IB) method and biodex system3, respectively, in 44 healthy male(20) and female(24) university students. 1. Muscular strength of the upper extremities correlated significantly with fat-free mass(FFM) with $r=.604{\sim}.630$ and intracellular fluid(ICF) with $r=.672{\sim}.668$ in males and FFM with $r=.416{\sim}.552$, ICF with $r=.432{\sim}.564$ and extracellular fluid(ECF) with $r=.429{\sim}.463$ in females. 2. Muscular strength of the lower extremities correlated significantly with FFM with $r=.522{\sim}.785$, ICF with $r=.501{\sim}.739$ and ECF with $r=.498{\sim}.796$ in males and FFM with $r=.642{\sim}.660$, ICF with $r=.627{\sim}.671$ and ECF with $r=.572{\sim}.623$ in females. 3. Muscular strength of the trunk correlated with FFM with $r=.595$, ICF with $r=.627$, ECF with $r=.448$ in males, but did not correlate significantly with body composition in females. These results suggest that total body water(TBW) and ICF may be factors directly associated with muscular strength as well as physical fitness.

  • PDF