• Title/Summary/Keyword: R2-loop

Search Result 283, Processing Time 0.028 seconds

Agonists of the Dioxin Receptor: Environmental Contaminants, Food Constituents, Microbial Metabolites, and Tumor Promoters

  • Schrenk, Dieter
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.11b
    • /
    • pp.90-105
    • /
    • 2002
  • The dioxin- or aryl hydrocarbon receptor (AhR) is a member of the Per-Arnt-Sim family of nuclear transcription factors exhibiting a basic helix-loop-helix structure. In its non-ligated state the AhR is associated with hsp 90 and the immunophilin-type XAP2. Upon ligand binding the associated proteins are released, the receptor dimerizes with the AhR nuclear trans locator protein Arnt, and binds to XREs (xenobiotic-responsive elements) in the 5'-flanking region of responsive genes thus modulating their transcription.(omitted)

  • PDF

Comparative Study on the Power Transfer Efficiency of Magnetic Resonance and Radio Frequency Wireless Power Transmission

  • Kim, Ye-Chan;Choi, Bo-Hee;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.232-234
    • /
    • 2016
  • In this paper, the power transfer efficiencies (PTEs) of magnetic resonance (MR) wireless power transmission (WPT) and radio frequency (RF) WPT are compared as a function of the distances between resonators (or antennas). The PTE of the C-loaded loop resonators during MR WPT was theoretically calculated and simulated at 6.78MHz, showing good agreement. The PTE of the patch antennas, whose area is the same as the C-loaded loop resonator during MR WPT, was theoretically calculated using the Friis equation and the equation by N. Shinohara and simulated at 5.8 GHz. The three results from the Friis equation, the equation by N. Shinohara, and from a full wave simulation are in strong agreement. The PTEs, when using the same size resonators and antennas are compared by considering the distance between the receiver and transmitter. The compared results show that the MR WPT PTE is higher than that of the RF WPT PTE when the distance (r) between the resonators (or antennas) is shorter. However, the RF WPT PTE is much higher than that of the MR WPT PTE when the distance (r) between the resonators (or antennas) is longer since the RF WPT PTE is proportional to $r^{-2}$ while the MR WPT PTE is proportional to $r^{-6}$.

The heat transfer characteristics of supercritical $CO_2$ in a horizontal tube (수평관내 $CO_2$의 초임계 영역내 열전달에 관한 연구)

  • Oh Hoo-Kyu;Lee Dong-Geon;Son Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.526-532
    • /
    • 2005
  • The cooling heat transfer coefficient of $CO_2$(R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter. a pre-heater and gas cooler(test section). The test section consists of a smooth, horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $400\;kg/m^{2}s$ and the inlet cooling pressure of 7.5 MPa to 10.0 MPa. The variation of heat transfer coefficient tends to decrease as cooling pressure of $CO_2$ increases. The heat transfer coefficient with respect to mass flux increases as mass flux increases. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with that predicted by Blasius's correlation. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Bringer-Smith.

Modeling and a Simple Multiple Model Adaptive Control of PMSM Drive System

  • Kang, Taesu;Kim, Min-Seok;Lee, Sa Young;Kim, Young Chol
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.442-452
    • /
    • 2017
  • This paper deals with the input-output modeling of a vector controlled PMSM drive system and design of a simple multiple model adaptive control (MMAC) scheme with desired transient responses. We present a discrete-time modeling technique using closed-loop identification that can experimentally identify the equivalent models in the d-q coordinates. A bank of linear models for the equivalent plant of the current loop is first obtained by identifying them at several operating points of the current to account for nonlinearity. Based on these models, we suggest a simple q-axis MMAC combined with a fixed d-axis controller. After the current controller is designed, another equivalent model including the current controller in the speed control loop shall be similarly obtained, and then a fixed speed controller is synthesized. The proposed approach is demonstrated by experiments. The experimental set up consists of a surface mounted PMSM (5 KW, 220V, 8 poles) equipped with a flywheel load of 220kg and a digital controller using DSP (TMS320F28335).

Design of a PLL Frequency Synthesizer for RSSI Applications Using Phase Noise Analysis (위상잡음 해석을 이용한 RSSI용 PLL 주파수합성기 설계)

  • Kim, Nam-Tae;Jeong, Jae-Han;Song, Han-Jung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.12
    • /
    • pp.28-34
    • /
    • 2011
  • In this paper, a PLL frequency synthesizer for RSSI applications is designed by phase noise analysis. Required synthesizer performance is achieved by optimizing the noise performance of PLL components and a loop transfer function, since its phase noise, lock time, and spur suppression capability are determined by the performance of loop components and loop filter characteristics. As an application example, a PLL frequency synthesizer for RSSI applications, which operates at the frequency of 2.288GHz, is designed using the phase noise analysis. The validity of the design technique is proved by experiments.

PLL Equivalent Augmented System Incorporated with State Feedback Designed by LQR

  • Wanchana, Somsak;Benjanarasuth, Taworn;Komine, Noriyuki;Ngamwiwit, Jongkol
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.2
    • /
    • pp.161-169
    • /
    • 2007
  • The PLL equivalent augmented system incorporated with state feedback is proposed in this paper. The optimal value of filter time constant of loop filter in the phase-locked loop control system and the optimal state feedback gain designed by using linear quadratic regulator approach are derived. This approach allows the PLL control system to employ the large value of the phase-frequency gain $K_d$ and voltage control oscillator gain $K_o$. In designing, the structure of phase-locked loop control system will be rearranged to be a phase-locked loop equivalent augmented system by including the structure of loop filter into the process and by considering the voltage control oscillator as an additional integrator. The designed controller consisting of state feedback gain matrix K and integral gain $k_1$ is an optimal controller. The integral gain $k_1$ related to weighting matrices q and R will be an optimal value for assigning the filter time constant of loop filter. The experimental results in controlling the second-order lag pressure process using two types of loop filters show that the system response is fast without steady-state error, the output disturbance effect rejection is fast and the tracking to step changes is good.

A Reference Spur Suppressed PLL with Two-Symmetrical Loops (기준 신호 스퍼의 크기를 줄인 두 개의 대칭 루프를 가진 위상고정루프)

  • Choi, Hyun-Woo;Choi, Young-Shig
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.5
    • /
    • pp.99-105
    • /
    • 2014
  • A reference spur suppressed PLL with two-symmetrical loops without changing the bandwidth which is optimized to suppress phase noise and reduce locking time has been designed. The principle of suppressing a reference signal spur is to stabilize the input voltage of voltage controlled oscillator (VCO). The proposed PLL consists of a phase-frequency detector(PFD) which has two outputs, two charge pumps(CP), two loop filters(LF), a divider and a VCO which has two inputs. Simulation results with $0.18{\mu}m$ CMOS process show that the reference spur is approximately suppressed to 1/2 of the reference spur in a conventional PLL. Even though there is a 5% process variation in the magnitude of R and C, the simulation result shows that the reference spur is still suppressed to 1/2 of the reference spur in a conventional PLL. The power consumption is 6.3mW at the power supply of 1.8V.

Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region (초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.

Vibrational control of an underactuated mechanical system (작동기가 불충분한 매니퓰레이터의 진동적 제어)

  • Lee, Kang-Ryeol;Hong, Keum-Shik;Lee, Kyo-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.151-154
    • /
    • 1997
  • An open loop vibrational control of underactuated mechanical systems with amplitude and frequency modulations is investigated. The underactuated systems considered in the paper are assumed to have free joints with no brake. The active joints are positioned first by a linearizing control, and then periodic oscillatory inputs are applied to them to move the remaining free joints to their desired states. A systematic way of obtaining averaged systems for the underactuated systems with oscillatory vibrations is developed. A complete solution to the open loop control strategy in terms of determining amplitudes and frequencies for general system is still under investigation. However, a specific control design for 2R manipulator which is obtained the averaging system is demonstrated.

  • PDF

Vibrational Control of an Underactuated Mechanical System : Control Design Using the Averaging Method (불충분한 작동기를 가진 기계시스템의 진동적제어: 평균화기법을 통한 제어 설계)

  • 이강렬;홍금식;이교일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.534-537
    • /
    • 1995
  • An open loop vibrational control of underactuated mechanical system with amplitude and frequency modulations is investigated. The underactuated systems sonsidered in the paper are assumed to have free joints with no brake. The active joints are positioned first by a linearizing control, and then periodic oscillatory input are applied to them to move the remaining free joints to their desired states. A systematic way of obtaining averaged systems for the underactuated systems with oscillatory vibration is developed. A complete solution to the open loop control strateegy in terms of determining amplitudes and frequencies for general system is still under investigation. However, a specific control design for 2R manipulator which is obtained through the averaged system is demonstrated.

  • PDF