• Title/Summary/Keyword: Quality Test

Search Result 11,035, Processing Time 0.037 seconds

Sleep Quality Evaluation Using Self-Reported Questionnaires in Patients with Burning Mouth Syndrome

  • Jin, Jung-Yong;Lee, Kyung-Eun;Suh, Bong-Jik
    • Journal of Oral Medicine and Pain
    • /
    • v.41 no.4
    • /
    • pp.188-194
    • /
    • 2016
  • Purpose: Burning mouth syndrome (BMS) is ambiguous and enigmatic oral condition. Sleep disturbance is one of the most prevalent complaints of patients with chronic pain. The aim of this study was to estimate general sleep characteristics and propensity in patients with BMS. Methods: A total of thirty BMS patients and thirty healthy control subjects were investigated. Self-reported measures of sleep quality were conducted using two widely used methods; the Pittsburgh Sleep Quality Index (PSQI) and Epworth Sleepiness Scale (ESS). Data were analyzed with one-way ANOVA, chi-square, Fisher's exact test, Kruskal-Wallis test, Holm method with 95% confidence interval and p<0.05 significant level. Results: BMS patients showed more poor sleepers than those in control subjects in both ESS and PSQI test. BMS patients also showed statistically significant poorer sleep quality compared with control subjects in both test. When BMS group were divided into three groups on the basis of numeric rating scale, the higher score subjects had, the more mean rank they had in the PSQI. Conclusions: BMS patients showed up poor sleep characteristics and propensity than control group, and they also showed the more severe the pain was, the worse the sleep quality was.

The field-test of Power Quality Meter and Power Management System in order to verify the performance (PQM 및 PQMS 성능검증을 위한 실증시험)

  • Choi, Sun-Kyu;Song, Il-Keun;Kwon, Tae-Ho;Han, Jae-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

DEVELOPMENT OF A SOUND QUALITY INDEX FOR THE EVALUATION OF BOOMING NOISE OF A PASSENGER CAR BASED ON REGRESSIVE CORRELATION

  • LEE J. K.;PARK Y. W.;CHAI J. B.;JANG H. K.
    • International Journal of Automotive Technology
    • /
    • v.6 no.4
    • /
    • pp.367-374
    • /
    • 2005
  • This paper proposes a sound quality index to evaluate the vehicle interior noise. The index was developed using a correlation analysis of an objective measurement and a subjective evaluation data. First, the objective set of measurements was obtained at two specified driving conditions. One is from a wide-open test condition and the other is from a constant-speed test condition. At the same time, subjective evaluation was carried out using a score of ten scale where 17 test engineers participated in the experiment. The correlation analysis between the psycho-acoustic parameters derived from the objective measurement and the subjective evaluation was performed. The most critical factors at both test conditions were determined, and the corresponding equations for the sound quality were obtained from the multiple factor regression method. Finally, a comparative work between previous index and present index was performed to validate the effectiveness of the proposed index.

The Correlation Study of the Jury Test and Sound Quality Metrics Evaluation for Impact Sound of the Golf Club (골프채 타격음에 대한 청취실험과 음질 평가지수 관련 연구)

  • Park, Hee-Jun;Kim, Kwan-Ju;Park, Jin-Gue;Kim, Sang-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.595-598
    • /
    • 2005
  • The impact sound of the golf club is one of the major factors to purchase it. Sound qualify evaluation techniques are mostly developed for harmonic sounds. Sound quality metrics for the impact sound is proposed in this study. Jury test, one of the typical subjective evaluation scheme, is carried out for evaluating the sound quality of 11 different golf drivers. Above subjective classification results are assumed to be the right answers. Conventional objective evaluation methods such as Zwicker loudness sensory pleasantness are calculated. Wavelet analysis and instantaneous loudness are applied in order to evaluate the transient sounds, which shows better correlation with the results from those by jury test.

  • PDF

A Test on Quality Improvement of Printed Circuit Board Using Mold Compensation (금형보정을 이용한 PCB 품질향상에 관한 실험)

  • 전영호;권이장
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.1
    • /
    • pp.135-141
    • /
    • 1997
  • The Copper-Clad Laminate (CCL) is a main electronic component of specialtype printed circuit boards (PCBs) such as Silver Through Hole PCB. This CCL should have high reliability under the aging test, and usually the test is done at a higher temperature (110-$150^{\circ}C$) than the normal. Then, this test condition of high temperature may cause such quality problems as hole eccentricity and reduction of distance between part holes. After measuring the CCL shrinkage affected by temperature, the correction factor of a press mold was a, pp.ied to solve these problems. The results showed that the tolerance of hole pitch(${\pm}$$100{\mu}m$) was satisfactory and the internal and external failure costs were reduced by 55%.

  • PDF

Investigation of Market Status of Imported Tires and Quality Evaluation (국내 교체용 타이어 수입실태 및 품질 성능 평가)

  • Hong, Seung-Jun;Lee, Ho-Guen
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.1-6
    • /
    • 2005
  • In domestic replacement tire market, imported tires are increasing condinuously. Because there is no institute officially investigating tire safety and performance, domestic drivers can be exposed to defective tires with no regulations. In this study we performed investigation of replacement tire market status and amount of imported tires. Over $90\%$ of imported tires are for passenger car and the number of total imported tires is increasing in recent years. Low price tires imported from Southeast Asia and China are selected to evaluate quality level. Basic inspection, indoor test, outdoor test, material test are conducted to evaluate the selected tires and compared with tires of domestic maker. From test results quality level of the selected tires could be found.

The Evaluation of Catalytic Trap Oxidizer on a City Bus (市內버스 煤煙防止를 위한 觸媒酸化濾過裝置의 實用化 硏究)

  • Cho, Kang-Rae;Kim, Yang-Kyun;Eom, Myung-Do;Kim, Chong-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.79-87
    • /
    • 1989
  • In order to reduce the smoke emission from the in-service city bus, this study was evaluated the particulate reduction efficiency and regeneration ability of the catalitic trap oxidizer (CTO) on the city bus (D0846HM engine) equipped with it. Before the on-road CTO test, the laboratory test of CTO on engine test-bench was performed. Reduction efficiencies of smokes and particulates were 54 and 45%, and those of gaseous pollutants such as carbon monoxide (CO) and hydrocarbons (HC) were 90 and 60%. In order to evaluate the regeneration ability of the CTO by the catalytic oxidation of trapped particulate, field test was performed on the in-service road. The regeneration temperature was 350$^\circ$ which was same with the exhaust temperature of city bus.

  • PDF

Status and Prospect of Test Methods of Quality Silicone Water Repellent for Protecting Reinforced Concrete

  • Sun, H.Y.;Yuan, Z.Y.;Yang, Z.;Shan, G.L.;Shen, M.X.
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.141-150
    • /
    • 2017
  • Impregnating with quality silicone water repellent on the concrete surface is an effective method of protecting concrete. Quality silicone water repellent has been widely used in the engineering profession because of its desirable properties such as hydrophobicity, keeping concrete breathable and preserving the original appearance of the concrete. The companies in China that produce silicone water repellent are listed. Test methods in the specifications or standards about silicone water repellent in China are summed. The test methods relative to durability of concrete impregnated with silicone water repellent (such as resistant to chloride ion penetration, resistant to alkali, resistance to freezing and thawing and weatherability etc.) and the constructive quality (such as water absorption rate, impregnating depth and the dry velocity coefficient etc.) are compared and analyzed. The results indicate that there are differences among test methods relative to different specifications with the same index and therefore, confusion has ensued when selecting test methods. All test methods with the exception of the method of water absorption rate by using a Karsten flask are not non-destructive methods or conducted in a laboratory. Finally, further research on silicone water repellent during application is proposed.

Bearing Capacity Evaluation of Drilled Shaft for Top & Down Method (탑다운 기초 현장타설말뚝의 지지력 평가)

  • Cho, Chun-Whan;Kim, Hong-Mook;Kim, Woong-Kyu;Kwon, Se-Oh;Sung, Byung-Wan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.58-65
    • /
    • 2004
  • Recently, the top & down method with drilled shafts as a foundation of high rise building is often adopted for the purpose of construction period reduction and construction cost effectiveness. It is common to omit the loading test as a Quality assurance on account of the high capacity of drilled shafts for the top & down method. It seems that the capacity of drilled shaft in recent top & down method is beyond that of conventional loading test method.However, the quality assurance for the drilled shaft as foundation of high rise building becomes much more important since the drilled shaft should bear much higher working load. It may be a small scale test pile could be an alternative as a quality assurance for the drilled shaft with high capacities. Through a case study, this paper gives an idea for solving the limitation of the conventional loading test method for the quality assurance of drilled shaft with high capacities. In particular, this paper analyzed the scale effect for a small drilled shaft installed into bedrock, which could be used for an alternative.

  • PDF

Effects of Hand Acupuncture Therapy on Sleep Quality in Sleep Disrupted Adults - Verification by Polysomnography and Cerebral Blood Flow Test - (수지요법이 수면장애를 가진 성인의 수면의 질에 미치는 효과 - 수면다원검사 및 뇌혈류 검사를 통한 검증 -)

  • Hwang, Eun-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.7
    • /
    • pp.1108-1118
    • /
    • 2007
  • Purpose: The purpose of this study was to identify the effects of hand acupuncture therapy on sleep quality by means of a sleep questionnaire, polysomnography and a cerebral blood flow test in $30{\sim}59$ year old adults. Methods: The study was a sham controlled design. Twenty-two adults were assigned to the pellet stimulating group (11) or sham group (11). The pellet stimulating group received hand acupuncture therapy using New Seoam Press Pellets number 1 for 4 weeks. On the other hand, the sham group used the same Adhesive tape in terms of shape, size and quality as New Seoam Press Pellets number 1 for 4 weeks. A Transcranial Doppler Ultrasonography and Carotid Duplex Ultrasonography examination were used for evaluating cerebral blood flow. Data was analyzed using the SPSS 12.0 version program with $X^2-test$, Fisher's exact test and Mann Whitney U-test. Results: In the pellet stimulating group, subjective sleep quality significantly improved more than that of the sham group. Among the sleep indices of the polysomnography, total sleep time and sleep latency of the sham group significantly improved. The cerebral blood flow test didn't show any differences. Conclusion: These results suggest that hand acupuncture therapy is effective for subjective sleep improvement only, not polysomnographical sleep indices and cerebral blood flow.