Proceedings of the Korean Geotechical Society Conference (한국지반공학회:학술대회논문집)
- 2004.03b
- /
- Pages.58-65
- /
- 2004
Bearing Capacity Evaluation of Drilled Shaft for Top & Down Method
탑다운 기초 현장타설말뚝의 지지력 평가
- Cho, Chun-Whan (T.A. Team, Samsung Corp.) ;
- Kim, Hong-Mook (Housing Construction Team(Civil), Samsung Corp.) ;
- Kim, Woong-Kyu (Housing Construction Team(Civil), Samsung Corp.) ;
- Kwon, Se-Oh (Housing Construction Team(Civil), Samsung Corp.) ;
- Sung, Byung-Wan (Housing Construction Team(Civil), Samsung Corp.)
- Published : 2004.03.25
Abstract
Recently, the top & down method with drilled shafts as a foundation of high rise building is often adopted for the purpose of construction period reduction and construction cost effectiveness. It is common to omit the loading test as a Quality assurance on account of the high capacity of drilled shafts for the top & down method. It seems that the capacity of drilled shaft in recent top & down method is beyond that of conventional loading test method.However, the quality assurance for the drilled shaft as foundation of high rise building becomes much more important since the drilled shaft should bear much higher working load. It may be a small scale test pile could be an alternative as a quality assurance for the drilled shaft with high capacities. Through a case study, this paper gives an idea for solving the limitation of the conventional loading test method for the quality assurance of drilled shaft with high capacities. In particular, this paper analyzed the scale effect for a small drilled shaft installed into bedrock, which could be used for an alternative.