• Title/Summary/Keyword: Quality Output

Search Result 1,503, Processing Time 0.029 seconds

Modeling and Analysis of Modified Active Frequency Drift Method (개선된 AFD기법의 모델링 및 분석)

  • An, Jin-Ung;Yu, Gwon-Jong;Choy, Ich;Choi, Ju-Yeop;Lee, Ki-Ok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.145-151
    • /
    • 2011
  • In this paper, among the active islanding detection techniques, the modified active frequency drift method was analyzed, which is relatively easy to apply to the single-phase grid-connected PV PCS. The existing designs for turbulences in these applications were empirically conducted, and do not have sufficient reliability and performance. Therefore, three application forms of the modified active frequency drift technique were modeled, based on which the proper magnitude of turbulence, which is the frequency acceleration component, was calculated. Using the results, the magnitude of and injection method for turbulence for ensuring the islanding detection performance and improving the output power quality were proposed, and they were verified via simulations and experiment to prove that the reliable islanding detection technique can be developed merely by measuring the basic output power quality, without the need for expensive islanding simulation equipment.

A Study on the Sensitivity Analysis of Line Source Air Quality Models (移動汚染源에 대한 大氣擴散模型의 感應度 分析에 관한 硏究 (HIWAY2, PAL, CALINE3 模型을 對象으로))

  • 김선태;김병태;김정욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.1-10
    • /
    • 1989
  • The sensitivity analysis is a method to quantify to what extent the output of a model changes with the values of input parameters. This will lead to increase model accuracy through measurement validation. Three line source air quality models, HIWAY 2, PAL, and CALINE 3 were selected for this study. The input parameters analysed included wind speed, wind direction, stability, emission rate, mixing height, receptor distance, initial dispersion coefficient, surface roughness, and averaging time. It turned out that PAL model generally showed higher concentration than other two models, and that between CALINE 3 and HIWAY 2, CALINE 3 showed higher concentration than HIWAY 2 model near the line sources, but beyond a certain downwind distances HIWAY 2 model showed higher concentration. The modesl were very sensitive to wind speed especially in the range of 0 $\sim$ 1 m/s and to wind direction near the parallel wind to streets. In case of emission rate, the output concentration was directly proportional to these input parameters. And the sensitivity of the input parameters such as stability, mixing height, initial dispersion coefficient, surface roughness, and averaging time were not very significant.

  • PDF

Development the Nursing Productivity Conceptual Framework (간호생산성 개념틀 개발에 관한 연구)

  • Park, Jung-Ho;Park, Kwang-Ok;Lee, Byung-Sook
    • The Korean Nurse
    • /
    • v.32 no.1
    • /
    • pp.47-60
    • /
    • 1993
  • This study was performed to develop the conceptual framework of the nursing productivity. The study efforts were made (1) to define the concept the nursing productivity, (2) to identify the elements of the productivity, and (3) to determine the relationship among the elements. With the aim, the study employed a descriptive analysis by way of reviewing various references related w the subject. The nursing productivity consists of such elements as the nursing efficiency and Lhe nursing effectiveness which are complememary Lo each other. The nursing efficiency is the quantative input/output ratio, while the nursing effectiveness represents the integrated outcome of sch sub-elements as the degree of accomplishing nursing goals, the quality of nursing service, consumer's satisfaction, and the degree of improvement of nurse's attitude toward the quality care. The nursing prodiccivity can be estimated by summing up the nursing efficiency and the effectiveness. By employing the system theory model, the elements of the nursing producTivity consist of three elements; the input, the process, and the output. By the process elements, the system inputs are transformed to the system outputs nursing efficiency and nursing effecitveness which are input 1.0 the system, in turn, through feedback mechanism(Figure 4).

  • PDF

A Study on the Rise for Rate of Operation in Utility Interactive Photovoltaic System (계통연계형 PV시스템의 가동률 향상에 관한 연구)

  • Han Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.97-100
    • /
    • 2004
  • Our country has depended on fossil fuel very much according to the Increasing of the demand of the electric power. For instance, if the reduction and freezing caused by the warm gas in earth by the regulation of international environment happen in Korea it will bring about the result of weakness in industrial activity. As a result, it will cause many problems to compete an advanced country which wants to connect environment with the activity of industrial product in their country. The photovoltaic system outputs have peak about a half past 13 o'clock(before and after) mainly in a good weather. The output decreases rapidly from a half past 17 o'clock and PV output doesn't work at six o'clock before the sun rises. The outputs of PV system stops at that time. The frequent degree of harmonics in dwelling house which lots of people live has peak from 19 o'clock to 22 o'clock Harmonics mainly happens at least at night. In recent, many researches about power quality has been studying very hard in order to solve the question, the voltage fluctuating and harmonics as one compensator. In this paper, I suggest the algorithm which can increase the power quality as a rate of operation of this system. This algorithm proves to have effectiveness through computer simulation.

  • PDF

A Control Scheme for Quality Improvement of Input-Output Current of Small DC-Link Capacitor Based Three-Level NPC Inverters (소용량 직류단 커패시터를 가지는 3-레벨 NPC 인버터의 입-출력 전류 품질 향상을 위한 제어 기법)

  • In, Hyo-Chul;Kim, Seok-Min;Park, Seong-Soo;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.369-372
    • /
    • 2017
  • This paper presents a control scheme for three-level NPC inverters using small DC-link capacitors. To reduce the inverter system volume, the film capacitor with small capacitance is a promising candidate for the DC-link. When small capacitors are applied in a three level inverter, however, the AC ripple component increases in the DC-link NPV (neutral point voltage). In addition, the three-phase input grid currents are distorted when the DC-link capacitors are fed by diode rectifier. In this paper, the additional circuit is applied to compensate for small capacitor systems defect, and the offset voltage injection method is presented for the stabilization in NPV. These two proposed processes evidently ensure the quality improvement of the input grid currents and output load currents. The feasibility of the proposed method is verified by experimental results.

A Study on the Evaluation of Efficiency in the Korean Small and Medium sized Construction Firms (국내 중소건설업체의 효율성 평가에 관한 연구)

  • Kim, Hyuk;Yoo, Han-Joo;Song, Gwang-Suk
    • Journal of Korean Society for Quality Management
    • /
    • v.38 no.3
    • /
    • pp.463-474
    • /
    • 2010
  • In this study, we evaluate the efficiency of Construction Industry using Data Envelopment Analysis(DEA). Since the Construction Industry has been traditionally operated through competition, it is important to measure the efficiency. In this paper, we empirically analyze the Efficiency of the 50 Korean Construction Industry. In detail, we used the scale of efficiency in order that efficiency cannot be affected by the total technical efficiency of each company and the scale of DMU by applying CCR or BBC model. Also, we analyzed the changes of measurement DEA model score. we adopted the basic DEA, RTS Region and MPSS(Most Productive Scale Size) method which are combined with efficiency measurement model in order to analyze the operational status. Furthermore, by complementing the shortfalls of the scale efficiency value of the DEA Model, RTS Region Model can be recommended to be appropriate in the evaluation of ideal input/output Quantity. In particular, input variables are total assets, construction capacity, the technical staff and output variables are sales volume, operating income. The result of RTS Region and MPSS shows that 9 DMUs of the efficiency frontier in the Construction Industry are analyzed to be relatively efficient DMUs, and 41 DMUs are analyzed to be inefficient DMUs, and finally inefficient DMUs are separated with Region 1 and Region 6.

Electric Characteristics of Disk-type Piezoelectric Transformer (디스크형 압전 변압기의 전기적 특성)

  • Kim, Dong-Soo;Kim, Kwang-Il;Kim, Heung-Rak;Jeong, Woo-Cheol;Nam, Hyo-Duk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.11
    • /
    • pp.1007-1013
    • /
    • 2005
  • In this study, a step-down piezoelectric transformer was fabricated to utilize as an adapter for charging batteries of mobile electronic appliances. The ceramic part of the transformer is $Pb[(Mn_{1/3}Sb_{2/3})_{_0.05}Zr_{0.475}Ti_{0.475}]O_3$ with mechanical quality factor of 1600, electromechanical coupling coefficient $59\%$, and piezoelectric constant $d_{33}$ 1300, which can be utilized as a piezoelectric transformer. A simply fabricated disk-typed test pattern of diameter 28 mm and thickness 2 mm was used to characterize output voltage, step-down ratio as a function of electrode area with the input remained constant, and power, efficiency as a function of input voltage, and temperature-dependent electric characteristics were evaluated. The sample APT1 showed the best properties. The highest admittance, effective electromechanical coupling coefficient and an appropriate mechanical quality factor were obtained at the sample with the input/output area ratio of 1:1.5 at the common electrode, and the condition of 20 $V_{rms}$, $50\;\Omega$ made the maximum efficiency of $95\%$. The temperature was increased by 14.7'E as the input voltage was increased for $50\;V_{rms},\;50\;\Omega$.

Comparison of piezoelectric flextentional sonar transducer simulations between a coupled FE-BEM and ATILA code (결합형 유한요소-경계요소 기법과 ATILA와의 압전체 유연성 쏘나 변환기 시뮬레이션 비교)

  • Soon-Suck Jarng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.559-567
    • /
    • 1999
  • A piezoelectric flextentional sonar transducer has been simulated using a coupled FE-BEM. The dynamics of the sonar transducer is modelled in three dimensions and is analyzed with external electrical excitation conditions. Different results are available such as steady-state displacement modes, underwater directivity patterns, resonant frequencies, bandwidths, quality factors, output acoustic powers and transmitting voltage responses. It is shown that the present barrel-stave sonar transducer of the piezoelectric material produces flextentional displacements which could be related with higher output power, lower quality factor and more omnidirectional beam pattern than other types of sonar transducers. The results of the present sonar transducer modelling are also compared with those of a commercial package such as ATILA.

  • PDF

Analysis of the Fixed Frequency LCL-type Converter at Continuous Current Mode Including Parasitic Losses (연속전류모드에서 기생손실들을 고려한 고정주파수 LCL형 컨버터 해석)

  • Park, Sangeun;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.785-793
    • /
    • 2016
  • This paper analyzes an LCL-type isolated dc-dc converter operating for constant output voltage in the continuous conduction mode(CCM) with resistances of parasitic losses-static drain-source on resistance of power switch, ESR of resonant network(L-C-L)-using a high loaded quality factor Q assumptions and fourier series techniques. Simple analytical expressions for performance characteristics are derived under steady-state conditions for designing and understanding the behavior of the proposed converter. The voltage-driven rectifier is analyzed, taking into account the diode threshold voltage and the diode forward resistance. Experimental results measured for a proposed converter at low input voltage and various load resistances show agreement to the theoretical performance predicted by the analysis within maximum 4% error. Especially in the case of low output voltages and large loads, It is been observed that introduction of both rectifier and the parasitic components of converter had considerable effect on the performance.

Precision Quality Assurance of the Multiple Dynamic Systems in Iterative Loaming and Repetitive Control with System and Disturbance Identification (반복학습제어와 시스템 및 외란인식기술을 응용한 복합구조물의 정밀도 품질보증)

  • 이수철
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.7 no.1
    • /
    • pp.10-15
    • /
    • 2002
  • It is presented to extended to an interaction matrix formulation to the problem of system and disturbance identification for a plant that is corrupted by both process and output disturbances. With only an assumed upper bound on the order of the system and an assumed upper bound on the number of disturbance frequencies, it is shown that both the disturbance-free model and disturbance effect can be recovered exactly from disturbance-corrupted input-output data without direct measurement of the periodic disturbances. The rich information returned by the identification can be used by an iterative learning or repetitive control system to eliminate unwanted periodic disturbances. Those can be helped to apply to the multiple dynamic systems for precision quality assurance.

  • PDF