• Title/Summary/Keyword: Quality Control standard

Search Result 1,215, Processing Time 0.121 seconds

한국제조기업 품질관리활동의 동적 분석 (An Dynamic Analysis of Quality Control in Korean Manufacturing Industry)

  • 이순룡;이광재
    • 산업경영시스템학회지
    • /
    • 제10권16호
    • /
    • pp.183-195
    • /
    • 1987
  • The effectiveness of quality control is contingent to adaptability to the present circumstance. The objectives of this study are to provide empirical data to carry out qualify control effectively. To accomplish this purpose, an empirical study was made by questionaire (mailing survey method, Feb. to Mar. in 1987). The sample is the 167 companies in Korean manufacturing industry. The main findings out of the analysis are as follows the stage of quality control is concentrated in appraisal phase, the company standard is equiped gradually in non-KS marked company and the need of economic evaluation about quality control is increased gradually. With a view to analysing of relationship between quality control and it's effect factors (company standard, KS mark, computer based information system), the methods of $\chi$$^2$ test are used. The company standard have a significant difference in top manager's altitude to duality control, operation stage of quality control. operation scope of qualify control and quality budgeting system but is insignificant with economic evaluation about duality control. Otherwise, KS mark is insignificant with the equality control activity except for operation scope. The quality information system based in computer have a significant difference in operation stage, operation scope and economic evaluation. Therefor, for the purpose of attaining effectiveness of quality control through the economic evaluation about quality control, the company standard and computer based duality information system must be utilized in quality control activity.

  • PDF

간호표준 적용이 근${\cdot}$골격장애 환자의 간호질에 미치는 효과 (The effect of using a Nursing Standards on the Quality of Nursing care in Musculo-skeletal Disorder Patients)

  • 최순옥
    • 간호행정학회지
    • /
    • 제9권1호
    • /
    • pp.89-101
    • /
    • 2003
  • Purpose : this study was to examine the effect of using a nursing standards for the quality of nursing care in musculo-skeletal patients. Method : The approach to nursing quality assurance evaluation was selected process-outcome framework. The subjects ware 100 case of musculo-skeletal patients in orthopedic surgery nursing care unit of E. university hospital in seoul. The data of a control group were collected from 23 December 2001 to 20 March 2002 and an experimental group were collected from 1 June to 25 August 2002. The instruments used for this study were a nursing care standards in musculo-skeletal disorder patients developed by the investigator and an evaluation tool for the quality of nursing care in orthopedic surgery patients developed by soon-ook Choi in 1995. It's reliability is Cronbach alpha=.8628. The data were analyzed by means of $x^1$-test, t-test, ANOVA with SPSS program. Results : This study are as fellows : 1. Scores of the quality of nursing care in standard 1 in the experimental group were higher than those of the control group with no significant difference(t=-8.793, p=.000), scores of the quality of nursing care in standard 2 in the experimental group were higher than those of the control group with significant difference(t=-8.793, p=.000) and standard 3 in the experimental group were higher than those of the control group with significant difference(t=-10.550, p=.000). scores of the quality of nursing care in standard 4 in the experimental group were higher than those of the control group with significant difference(t=-8.793, p=.000). scores of the quality of nursing care in standard 4 in the experimental group were higher than those of the control group with no significant difference(t=-1.833, p=.070). 2. Scores of the quality of nursing care in criteria 28 of 33 criteria in the experimental group were higher than those of the control group with significant difference in 12 criteria(p<.05 ). 3. Scores of the quality of nursing care in standard 1 to standard 4(process evaluation); the experimental group were higher than those of the control group with significant difference(t=-10.704, p=.000). scores of the quality of nursing care in standard 5(outcome evaluation); the experimental group were higher than those of the control group. but no significant difference(t=-1.833, p=.070). 4. Scores of the quality of nursing care in experimental group were higher than those of the control group with significant difference(t=-10.794, p=.000). Conclusion : Through this study, I'm sure that using a nursing care standards in musculo-skeletal disorder patients improve quality of nursing care and nursing care standards are effective nursing care.

  • PDF

Generation of Newly Discovered Resistance Gene mcr-1 Knockout in Escherichia coli Using the CRISPR/Cas9 System

  • Sun, Lichang;He, Tao;Zhang, Lili;Pang, Maoda;Zhang, Qiaoyan;Zhou, Yan;Bao, Hongduo;Wang, Ran
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권7호
    • /
    • pp.1276-1280
    • /
    • 2017
  • The mcr-1 gene is a new "superbug" gene discoverd in China in 2016 that makes bacteria highly resistant to the last-resort class of antibiotics. The mcr-1 gene raised serious concern about its possible global dissemination and spread. Here, we report a potential anti-resistant strategy using the CRISPR/Cas9-mediated approach that can efficiently induce mcr-1 gene knockout in Escherichia coli. Our findings suggested that using the CRISPR/Cas9 system to knock out the resistance gene mcr-1 might be a potential anti-resistant strategy. Bovine myeloid antimicrobial peptide-27 could help deliver plasmid pCas::mcr targeting specific DNA sequences of the mcr-1 gene into microbial populations.

가중표준편차를 이용한 가변표본채취간격 $\bar{X}$ 관리도 (Variable Sampling Interval $\bar{X}$ Control Chart Using Weighted Standard Deviation Method)

  • 장영순
    • 한국경영과학회지
    • /
    • 제39권1호
    • /
    • pp.1-12
    • /
    • 2014
  • This article proposes a variable sampling interval (VSI) $\bar{X}$ control chart using weighted standard deviation (WSD) method for skewed populations. The WSD method decomposes the standard deviation of a quality characteristic into upper and lower deviations and adjusts control limits and warning limits of a control chart in accordance with the direction and degree of skewness. A control chart constant is derived for estimating the standard deviation of skewed distributions with the mean of sample standard deviations. The proposed chart is compared with the conventional VSI $\bar{X}$ control chart under some skewed distributions. Simulation study shows that the proposed WSD VSI chart can control the in-control average time to signal (ATS) as an adequate level better than the conventional VSI chart, and the proposed chart can detect a decrease in the process mean of a quality characteristic following a positively skewed distribution more quickly than the standard VSI chart.

약용식물의 품질평가 현황과 전망 (Current Status and Prospects for the Quality Evaluation of Medicinal Plants)

  • 김관수;류수노
    • 한국작물학회지
    • /
    • 제47권
    • /
    • pp.186-199
    • /
    • 2002
  • This is a brief review and discussion for present status and prospects of quality evaluation in medicinal plants as oriental medicine materials (OMM). Quality in medicinal plants could be defined as the combination of origin, external appearance, effectiveness and safety, and be evaluated by plant taxonomic, morphological, physiochemical and biological methods. For high-quality improvement and standardization of OMM, medicinal plants should be produced through using proper species or good variety and standard cultivation method in suitable cultivation area. Standardizing of quality means to meet with minimum qualifying criteria of OMM in the market while improving of quality to be over standard quality of medicinal piano in production. For making new high quality and standardized products, we need to keep standard field plants, standard OMM, standard plant specimen, and standard compounds. Researchers and administration have to study and propose the quality factors and their evaluating techniques and criteria, so high-quality and standardized produce of medicinal plane could be produced and distributed under the control of the relevant regulations, and would be contributed to increasing of national health.

지속적으로 향상되는 공정에서 기하 조정 관리한계를 사용한 $\overline{X}$ 관리도 ([ $\overline{X}$ ] Chart with Geometrically Adjusted Control Limits under Continually Improving Processes)

  • 유미정;박창순
    • 품질경영학회지
    • /
    • 제34권4호
    • /
    • pp.125-132
    • /
    • 2006
  • An adjusted control limit of the $\overline{X}$ chart is proposed for monitoring the continually improving processes. The continual improvement of the process implies the decrease of the process variance, which is represented by a logistic curve. The process standard deviation is estimated by the exponentially weighted moving average of the sample standard deviations from the past to the current times. The control limits are adjusted by the estimated standard deviation at every sampling time. The performance of the adjusted control limit is compared with that of the standard control limits for various cases of the decreasing speed and size of the variance. The results show that the $\overline{X}$ chart with the adjusted control limits provides better performances for monitoring the small and moderate shifts in continually improving processes.

계열별 자착형 방수시트의 성능 품질기준 개선안에 관한 연구 (A Study on Performance Standards of Quality Improvements of Self-adhesive Waterproofing Sheets by Materials)

  • 박진상;전종수;송제영;배기선;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.303-304
    • /
    • 2013
  • The field application through the quality control of self adhesive rubberized asphalt waterproofing sheet was regulated by KS F 4934 of Korea Standard in 2003. However, the regulations that the different material properties of self-Adhesive waterproofing sheets are difficult to quality control on the standard. Therefore, this research was performed for of quality control all affiliations of self-adhesive waterproofing sheet through basic properties test and proposed quality standard revised bill in KS F 4934.

  • PDF

먹는물 수질오염물질 표준시료에 대한 신뢰도 검증 - 질산성질소, 불소 - (Quality Control on Standard Samples of $N-NO_3$ and $F^-$ of Drinking Water Quality Pollutant)

  • 박선구;송기봉;김평청
    • 분석과학
    • /
    • 제13권2호
    • /
    • pp.229-233
    • /
    • 2000
  • 질산성질소와 불소의 저농도 $0.74mgN(NO_3)/l$, $0.58mgF^-/l$ 및 고농도 $2.14mgN(NO_3)/l$, $1.25mgF^-/l$ 표준시료에 대해 정도관리차트에 따라 신뢰도를 검증한 결과 정밀도가 각각 0.010, 0.017, 0.056, 0.019로 우수하게 나타났다. 분석의 숙련도가 다른 A, B, C 세명에 대해 각각의 표준시료로 6회 반복 측정분석한 결과 학력 및 연구경력이 가장 나은 C가 A, B보다 신뢰도가 우수한 측정분석결과를 산출하였다. 3명 모두 평균값이 조제값에 아주 가까운 분석데이타를 산출함으로서 이 표준시료를 외부정도관리 평가용으로 사용하기에 적합하다는 것을 알 수 있었다.

  • PDF

강재 파이프서포트의 압축하중 시험에 따른 안전 및 품질관리 기준 개선에 관한 연구 (A Study on Improvement of Safety & Quality Management Standard Based on Compression Tests of Steel Pipe Supports)

  • 오병한;최병정
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.94-103
    • /
    • 2018
  • As of July 1, 2017, the method of quality management of construction equipment had been changed completely. In case of manufacturing and distributing pipe supports, the support length according to the safety certification standard shall be not more than 6 m and the compressive strength shall be not less than 40,000 N at the maximum height. However, the field tests for the quality control standard were usually performed at 3.5 m when the length of the pipe supports is 3.5 m to 4.0 m, and the compression strength was specified to be more than 35,300 N. This difference in the two standards can cause confusion in practice. In this study, the compression load of the pipe supports was tested and found to be more than 30% defective. Therefore, it is necessary to review the modification of the safety certification and quality standards to improve the standard requirements.

음용수질 기준과 관리방안 (Recent Development of Drinking Water Quality Standard and its Application)

  • 권숙표
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.83-94
    • /
    • 1992
  • Recently water demand is increasing as the industry prospers. The increase of water demand is followed by the increase of wastewater discharge which pollutes rivers and ground water extensively. These rivers, reservoirs and ground water are sources for drinking water and their contamination affects the quality of water supply and other potable water. In Korea there are 776 water treatment plants which supply drinking water from main rivers or reservoirs. Rivers are the biggest water source for drinking water is being contaminated, the innovation of treatment process is needed. The construction and operation of water supply facilities is under the control of the Ministry of Construction and the water supply offices of cities and provinces. However, drinking water quality is under the control of the bureau of sanitation in the Ministry of Health and Social Affairs. There are 33 items in drinking water quality standards of Korea. Trihalomethanes, Selenium, Diazinone and other three of pesticides have been included lately, The Ministry of Health and Social Affairs is planning to enhance. the level of $VOC_S$(Vola-tile Organic Compounds) standard. Drinking water quality standard is the goal to protect the quality of supply water and ground water. In order to protect the source water from domestic or industrial water, technological improvement and adequate investment should be urgently made. The ultimate goal of drinking water quality is safety and health of consumers. The more stringent the standard are, the better the water quality will be. As the drinking water quality standards become more stringent this year, various and positive solutions by the authorities concerned must be prepared.

  • PDF