• Title/Summary/Keyword: QCT

Search Result 33, Processing Time 0.028 seconds

DXA and QCT in the Same Object of the Comparative Study of L-Spine BMD (동일개체에서 DXA와 QCT의 L-Spine BMD 비교)

  • Lim, Chung-Whan;Han, Beom-Hee;Lee, Sang-Ho;Ra, Kil-Soo
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.349-354
    • /
    • 2010
  • March-June 2010 I hospitals and N of 22 patients in the hospital by DXA and QCT BMD measured at the same object were compared, statistical methods SPSS for Windows program (version 12.0) using the frequency analysis and t-test with a bone age, height, weight, the correlation analysis results were as follows. The distribution of study subjects 19 cases were male and 3 female patients, total 22 patients, 37 years of age ranged from 28 years of age. The mean age of 32.14 years old, and their average height is 170.59 cm, with the average weight was 69.41 kg. In addition to DXA and QCT of how the L2-L4 BMD in level average correlation coefficient was 0.378 with a significant quantitative correlation. Analysis by age rather than the QCT method to DXA showed that 10.8% more valuable, than height level analysis to DXA, QCT method showed 3.4 percent more useful, weight level analysis to DXA is more useful than the 1.2% QCT method was. More results from this study to measure bone density in the DXA method is useful in the age and height and weight by some in the QCT method proved to be useful. Therefore, bone mineral density in patients' age, height, weight, depending on the selection of accurate measurement is considered to be considered.

Does Simultaneous Computed Tomography and Quantitative Computed Tomography Show Better Prescription Rate than Dual-energy X-ray Absorptiometry for Osteoporotic Hip Fracture?

  • Ko, Jae Han;Lim, Suhan;Lee, Young Han;Yang, Ick Hwan;Kam, Jin Hwa;Park, Kwan Kyu
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.233-240
    • /
    • 2018
  • Purpose: This study aimed to evaluate the efficacy of simultaneous computed tomography (CT) and quantitative CT (QCT) in patients with osteoporotic hip fracture (OHF) by analyzing the osteoporosis detection rate and physician prescription rate in comparison with those of conventional dual-energy X-ray absorptiometry (DXA). Materials and Methods: This study included consecutive patients older than 65 years who underwent internal fixation or hip arthroplasty for OHF between February and May 2015. The patients were assigned to either the QCT (47 patients) or DXA group (51 patients). The patients in the QCT group underwent QCT with hip CT, whereas those in the DXA group underwent DXA after surgery, before discharge, or in the outpatient clinic. In both groups, the patients received osteoporosis medication according to their QCT or DXA results. The osteoporosis evaluation rate and prescription rate were determined at discharge, postoperative (PO) day 2, PO day 6, and PO week 12 during an outpatient clinic visit. Results: The osteoporosis evaluation rate at PO week 12 was 70.6% (36 of 51 patients) in the DXA group and 100% in the QCT group (P<0.01). The prescription rates of osteoporosis medication at discharge were 70.2% and 29.4% (P<0.001) and the cumulative prescription rates at PO week 12 were 87.2% and 60.8% (P=0.003) in the QCT and DXA groups, respectively. Conclusion: Simultaneous CT and QCT significantly increased the evaluation and prescription rates in patients with OHF and may enable appropriate and consistent prescription of osteoporosis medication, which may eventually lead to patients' medication compliance.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

Effects of 2-deoxy-D-glucose and quercetin on the gene expression of bone sialoprotein and osteocalcin during the differentiation in irradiated MC3T3-E1 osteoblastic cells (2-deoxy-D-glucose와 quercetin이 방사선조사 MC3T3-E1 골모세포주의 분화시 bone sialoprotein과 osteocalcin 유전자의 발현에 미치는 영향)

  • Lee, Ji-Un;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.121-132
    • /
    • 2009
  • Purpose : To investigate the effects of 2-deoxy-D-glucose (2-DG) and quercetin (QCT) on gene expression of bone sialoprotein (BSP) and osteocalcin (OC) during the differentiation in irradiated MC3T3-E1 osteoblastic cells. Materials and Methods : When MC3T3-E1 osteoblastic cells had reached 70-80% confluence, cultures were transferred to a differentiating medium supplemented with 5 mM 2-DG or $10{\mu}M$ QCT, and then irradiated with 2, 4, 6, and 8 Gy. At various times after irradiation, the cells were analyzed for the synthesis of type I collagen, and expression of BSP and OC. Results : The synthesis of type I collagen in cells exposed to 2 Gy of radiation in the presence of 2-DG or QCT showed no significant difference compared with the control group within 15 days post-irradiation. When the cells were irradiated with 8 Gy, 2-DG facilitated the irradiation mediated decrease of type I collagen synthesis, whereas such decrease was inhibited by treating with QCT. During MC3T3-E1 osteoblastic cell differentiation, the mRNA expression of BSP and OC showed the peak value at 14 days and 21 days, respectively. 2-DG or QCT treatment alone decreased the level of BSP mRNA, but increased the OC mRNA level only at early time of differentiation (day 7). In the cells irradiated with 2, 4, 8 Gy, the mRNA expression of BSP and OC decreased at 7 days after the irradiation. The cells were treated with various dose of radiation in the presence of 2-DG or QCT, the mRNA level of both BSP and OC increased although this increase was observed at low dose of radiation (2 Gy) and at the early stage of differentiation. However, when the cells were exposed to 4, 6, or 8 Gy, the increase of BSP and OC mRNAs was detected only in cells co-incubated with QCT. Conclusion : This study demonstrates that 2-DG and QCT affect differently the expression of bone formation related factors, type I collagen, BSP, and OC in the irradiated MC3T3-E1 osteoblasic cells, according to the dose of radiation and the times of differentiation. Overall, the present findings suggest that 2-DG and QCT could have the regulatory roles as radiation-sensitizer and -protector, respectively.

  • PDF

The Comparative Study on Bone Mineral Density Accessed by Quantitative Computed Tomography and Quantitative Ultrasound (정량적 전산화단층촬영법(QCT)과 정량적 초음파법(QUS)에 의한 골밀도측정 비교)

  • Kim, Gi-Bum;Ahn, Sung-Min;Lee, Gui-Won;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.8
    • /
    • pp.198-203
    • /
    • 2011
  • The BMD difference depending on QCT and QUS, whose usages are recently being increased for the test of BMD, was accessed for 106 subjects of a general health examination who were aged between 24~69 year-old and results were derived as follows. The measured value of BMD by QCT and QUS showed significant correlation in general (p>0.05). In terms of the difference generated between the measurement methods depending on sexes, the female subjects showed significantly low T-score in the test made through QUS (p<0.05). Depending on ages, there was T-score difference among the subjects aged more than 40 year-old within significant range (p<0.05). When it came to the effect depending on heights and on weights, no group showed significant difference and in a group with less than 22.9 of BMI value, the T-score was measured significantly low when testing it through QCT while other groups were not affected by any testing methods. Likewise, it may require a different measurement method when it comes to the measurement of bone mineral density depending on sex, age, height, and BMI among patients. Thus, it suggests obtaining accurate data by conducting various testing methods in case of a special occasion.

Machine Learning Model to Predict Osteoporotic Spine with Hounsfield Units on Lumbar Computed Tomography

  • Nam, Kyoung Hyup;Seo, Il;Kim, Dong Hwan;Lee, Jae Il;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.442-449
    • /
    • 2019
  • Objective : Bone mineral density (BMD) is an important consideration during fusion surgery. Although dual X-ray absorptiometry is considered as the gold standard for assessing BMD, quantitative computed tomography (QCT) provides more accurate data in spine osteoporosis. However, QCT has the disadvantage of additional radiation hazard and cost. The present study was to demonstrate the utility of artificial intelligence and machine learning algorithm for assessing osteoporosis using Hounsfield units (HU) of preoperative lumbar CT coupling with data of QCT. Methods : We reviewed 70 patients undergoing both QCT and conventional lumbar CT for spine surgery. The T-scores of 198 lumbar vertebra was assessed in QCT and the HU of vertebral body at the same level were measured in conventional CT by the picture archiving and communication system (PACS) system. A multiple regression algorithm was applied to predict the T-score using three independent variables (age, sex, and HU of vertebral body on conventional CT) coupling with T-score of QCT. Next, a logistic regression algorithm was applied to predict osteoporotic or non-osteoporotic vertebra. The Tensor flow and Python were used as the machine learning tools. The Tensor flow user interface developed in our institute was used for easy code generation. Results : The predictive model with multiple regression algorithm estimated similar T-scores with data of QCT. HU demonstrates the similar results as QCT without the discordance in only one non-osteoporotic vertebra that indicated osteoporosis. From the training set, the predictive model classified the lumbar vertebra into two groups (osteoporotic vs. non-osteoporotic spine) with 88.0% accuracy. In a test set of 40 vertebrae, classification accuracy was 92.5% when the learning rate was 0.0001 (precision, 0.939; recall, 0.969; F1 score, 0.954; area under the curve, 0.900). Conclusion : This study is a simple machine learning model applicable in the spine research field. The machine learning model can predict the T-score and osteoporotic vertebrae solely by measuring the HU of conventional CT, and this would help spine surgeons not to under-estimate the osteoporotic spine preoperatively. If applied to a bigger data set, we believe the predictive accuracy of our model will further increase. We propose that machine learning is an important modality of the medical research field.

Effects of 2-deoxy-D-glucose and quercetin on cytokine secretion and gene expression of type I collagen during osteoblastic differentiation in irradiated MC3T3-El cells

  • Song Haeng-Un;Ahn Hyoun-Suk;Lee Sang-Rae;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.35 no.4
    • /
    • pp.191-198
    • /
    • 2005
  • Purpose: To characterize the effects of 2-deoxy-D-glucose (2DG) and quercetin (QCT) on cytokine secretion of IL-6, $TGF-\beta$ and gene expression of Col I in irradiated MC3T3-E1 cells Materials and Methods: The MC3T3-El cells were cultured in an a-MEM supplemented with 5mM 2DG or 10mM QCT and then the cells were incubated 12h before irradiation with 2, 4, 6, and 8Gy X-ray using a linear accelerator delivered at a dose rate of 1.5Gy/min. Level of IL-6 and $TGF-\beta$ was determined by ELISA. Also expression of Col I was examined by RT-PCR. Results: In accordance with the radiation dose, the amount of $TGF-\beta$ was not different in RA + QCT, but it showed a peak value in control and RA + 2DG at 4Gy on the 3rd day. However, all groups showed a decreasing tendency dose-dependently in RA+QCT on the 7th day (p<0.01). In accordance with the radiation dose, the amount of IL-6 increased dose-dependently in all groups on the 3rd day. On the 7th and 21st day, all groups showed peak values at 4Gy. RA+QCT showed a slightly increased amount of IL-6 at 2Gy, but it showed a slightly decreased amount at 4, 6, and 8Gy. In accordance with the period of culture after irradiation, the expression of Col I increased dose-dependently in RA+QCT. Conclusion: The result showed that QCT acted as radiosensitizer in the secretion of $TGF-\beta$ and gene expression of Col I during differentiation in irradiated MC3T3-E1 cells at the cellular level.

  • PDF

Spectroscopic Properties of Quercetin in AOT Reverse Micelles

  • Park, Hyoung-Ryun;Im, Seo-Eun;Seo, Jung-Ja;Bark, Ki-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.828-832
    • /
    • 2014
  • The spectroscopic properties of quercetin (QCT) were studied in the AOT reverse micelle by fluorescence spectroscopy. Because the molecular structure of QCT is completely planar, excited state intramolecular proton transfer (ESIPT) occurs between the -OH at C(5) and carbonyl oxygen via intramolecular hydrogen bonding. This ESIPT happens at the $S_1$ state but not at the $S_2$ state. Because QCT is a good donor-acceptor-conjugated molecule at the excited state, this molecule can emit strong fluorescence but shows no $S_1{\rightarrow}S_o$ emission due to this ESIPT. Since the $S_2{\rightarrow}S_1$ internal conversion was very slow due to the small Franck-Condon factors, $S_2{\rightarrow}S_o$ fluorescence emission was observed. All of the experimental results indicated that the QCT resided at the bound water interface and that the position of solute did not change significantly in the micelle at various water concentrations.

Spectroscopic Properties of Flavonoids in Various Aqueous-Organic Solvent Mixtures

  • Park, Hyoung-Ryun;Daun, Yu;Park, Jong Keun;Bark, Ki-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.211-220
    • /
    • 2013
  • The characteristic fluorescence properties of quercetin (QCT) and apigenin (API) were studied in various $CH_3OH-H_2O$ and $CH_3CN-H_2O$ mixed solvents. The structure of QCT is completely planar. API is not planar at the ground state but becomes nearly planar at the excited state. If the molecules are excited to the $S_1$ state in organic solvents, QCT exhibits no fluorescence due to excited state intramolecular proton transfer (ESIPT) between the -OH and the carbonyl oxygen, but API shows significant fluorescence because ESIPT occurs slowly. If the molecules are excited to the $S_2$ state, both QCT and API exhibit strong $S_2{\rightarrow}S_o$ emission without any dual fluorescence. As the $H_2O$ composition of both solvents increases, the fluorescence intensity decreases rapidly due to the intermolecular hydrogen bonding interaction. The theoretical calculation further supports these results. The change in fluorescence properties as a function of the solvatochromic parameters was also studied.

COMPARATIVE HISTOMORPHOMETRIC ANALYSIS OF MANDIBLE AND ILIAC BONE ON BONE DENSITY (하악골과 장골의 조직형태계측 비교)

  • Yoo, So-Jeong;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.12-25
    • /
    • 2000
  • To demonstrate possible influences of general bone density on the mandible, histomorphometric analysis was carried out in mandibles and iliac bones and the correlation of the two bone densities was tested. Comparison of bony density in women and men over 60 years in the mandible was carried out too. Quantitative computed tomography(QCT) was taken in cross-section of mandibles at the same site where histomorphometric analysis was peformed to evaluate the reliability of QCT. The analysis included 40 cadavers with no known diseases affecting the bones. The subjects consisted of 15 females and 25 males with a mean age of 60.3 years. Spearman correlation analysis and Wilcoxon rank sum test was performed. The results were as follows. 1. There was statistically no correlation between the mandible and iliac bone in the values of corrected cortical width(CCW), cortical porosity(POR) in cortex, and total bone volume(TBV), mean trabecular plate thickness(MTPT), mean trabecular plate density(MTPD), and mean trabecular plate separation(MTPS) in trabecular bone. 2. Comparison of women and men over 60 years, men had statistically higher bone density than women except fir POR of buccal and lingual cortex, and WTPD of alveolar trabeculae in mandible. 3. There was statistically significant correlation between TBV of trabecular bone and CT No., but not between POR and CT No. in mandible. According to the results above, there was no correlation between mandible and iliac bone density and between mandibular bony density and age. Further studies are required to support the results. A more noninvasive method to be able to measure the bone density of mandible should be developed and it is necessary to accumulate data on the normal values of bone density of mandible according to age and sex. Further study should be carried out about QCT to measure mandibular bony density using QCT.

  • PDF