• Title/Summary/Keyword: Pulsed laser photoacoustic method

Search Result 6, Processing Time 0.023 seconds

Enhancement of Pulsed-Laser Ablation by Phase Explosion of Liquid (액체의 상폭발 과정에 의한 펄스 레이저 용발률의 증진)

  • Kim, Dong-Sik;Lee, Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1483-1491
    • /
    • 2001
  • Enhancement of pulsed-laser ablation by an artificially deposited liquid film is presented. Measurements of ablation rate, ablation threshold, and surface topography arc performed. Correlation between material ablation and photoacoustic effect is examined by the optical beam deflection method. The dependence of ablation rate on liquid-film thickness and chemical composition is also examined. The results indicate that photomechanical effect in the phase explosion of liquid is responsible for the enhanced ablation. The low critical temperature of liquid induces explosive vaporization with localized photoacoustic excitation in the superheat limit and increases the ablation efficiency. Experiments were carried out utilizing a Q-swiched Nd:YAG laser at near-threshold laser fluences with negligible plasma effect (up to ∼100 MW/cm$^2$).

$CO_2$ Laser Absorption Measurement of $CH_3CH_2Br$ using Photoacoustic Method

  • Jang Soo Shin;Kyung Hoon Jung;Cheol Jung Kim
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.5
    • /
    • pp.553-556
    • /
    • 1992
  • The ${CO}_2$ laser absorption measurement of ${CH}_3{CH}_2Br$ utilizing photoacoustic (PA) technique was performed using a cw and a pulsed ${CO}_2$ lasers. The absorption profile in the ${CO}_2$ laser wavelength region (9-10 ${\mu}$m) and the macroscopic small signal absorption cross section at 10P(20) (10.59 ${\mu}$m, 944 $cm^{-1}$) laser line were measured using a cw ${CO}_2$ laser. The laser fluence dependence on infrared multiphoton absorption (IRMPA) was also studied with a pulsed TEA ${CO}_2$ laser at 10P(20) laser line. In view of monotonic increase of PA signal with the rise of laser fluence, it was suggested that the anharmonicity in pumped vibration mode did not restrict ir multiphoton absorption in ${CH}_3{CH}_2Br$ system as found in large molecular system.

Analysis of Nanosecond Explosive Vaporization Process by Photothermal/Photoacoustic Methods (광열/광음 기법에 의한 나노초 폭발적 기화 과정 분석)

  • Park, Hee-K.;Grigoropoulos, Costas P.;Choi, Sun R.;Kim, Dong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.804-812
    • /
    • 2003
  • This paper introduces optical methods for in-situ measurement of surface temperature and pressure transient in thermal processes having nanosecond time scales. In the temperature measurement, a p -Si thin film whose refractive index is calibrated as a function of temperature is embedded beneath the sample surface and the photothermal reflectance is monitored for estimating the surface temperature. The pressure transients are measured using the photoacoustic optical deflection method. The experimental technique is used to analyze the nanosecond laser induced vaporization process that is central to numerous engineering and bio-medical applications. Based on the experimental results, discussions are made on the experimental technique and the physical mechanisms of laser-driven explosive vaporization phenomena.

Frequency Domain Analysis of Laser and Acoustic Pressure Parameters in Photoacoustic Wave Equation for Acoustic Pressure Sensor Designs

  • Tabaru, Timucin Emre;Hayber, Sekip Esat;Saracoglu, Omer Galip
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.250-260
    • /
    • 2018
  • A pressure wave created by the photoacoustic effect is affected by the medium and by laser parameters. The effect of these parameters on the generated pressure wave can be seen by solving the photoacoustic wave equation. These solutions which are examined in the time domain and the frequency domain should be considered by researchers in acoustic sensor design. In particular, frequency domain analysis contains significant information for designing the sensor. The most important part of this information is the determination of the operating frequency of the sensor. In this work, the laser parameters to excite the medium, and the acoustic signal parameters created by the medium are analyzed. For the first time, we have obtained solutions for situations which have no frequency domain solutions in the literature. The main focal point in this work is that the frequency domain solutions of the acoustic wave equation are performed and the effects of the frequency analysis of the related parameters are shown comparatively from the viewpoint of using them in acoustic sensor designs.

Photoacoustic imaging of occlusal incipient caries in the visible and near-infrared range

  • da Silva, Evair Josino;de Miranda, Erica Muniz;de Oliveira Mota, Claudia Cristina Brainer;Das, Avishek;Gomes, Anderson Stevens Leonidas
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: This study aimed to demonstrate the presence of dental caries through a photoacoustic imaging system with visible and near-infrared wavelengths, highlighting the differences between the 2 spectral regions. The depth at which carious tissue could be detected was also verified. Materials and Methods: Fifteen permanent molars were selected and classified as being sound or having incipient or advanced caries by visual inspection, radiography, and optical coherence tomography analysis prior to photoacoustic scanning. A photoacoustic imaging system operating with a nanosecond pulsed laser as the light excitation source at either 532 nm or 1064 nm and an acoustic transducer at 5 MHz was developed, characterized, and used. En-face and lateral(depth) photoacoustic signals were detected. Results: The results confirmed the potential of the photoacoustic method to detect caries. At both wavelengths, photoacoustic imaging effectively detected incipient and advanced caries. The reconstructed photoacoustic images confirmed that a higher intensity of the photoacoustic signal could be observed in regions with lesions, while sound surfaces showed much less photoacoustic signal. Photoacoustic signals at depths up to 4 mm at both 532 nm and 1064 nm were measured. Conclusion: The results presented here are promising and corroborate that photoacoustic imaging can be applied as a diagnostic tool in caries research. New studies should focus on developing a clinical model of photoacoustic imaging applications in dentistry, including soft tissues. The use of inexpensive light-emitting diodes together with a miniaturized detector will make photoacoustic imaging systems more flexible, user-friendly, and technologically viable.

Nanocomposite-Based Energy Converters for Long-Range Focused Ultrasound Treatment

  • Lee, Seung Jin;Heo, Jeongmin;Song, Ju Ho;Thakur, Ujwal;Park, Hui Joon;Baac, Hyoung Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.369-369
    • /
    • 2016
  • A nanostructure composite is a highly suitable substance for photoacoustic ultrasound generation. This allows an input laser beam (typically, nanosecond pulse duration) to be efficiently converted to an ultrasonic output with tens-of-MHz frequency. This type of energy converter has been demonstrated by using a carbon nanotube (CNT)-polydimethylsiloxane (PDMS) composite film that exhibit high optical absorption, rapid heat transition, and mechanical durability, all of which are necessary properties for high-amplitude ultrasound generation. In order to develop the CNT-PDMS composite film, a high-temperature chemical vapor deposition (HTCVD) method has been commonly used so far to grow CNT and then produce a CNT-PDMS composite structure. Here, instead of the complex HTCVD, we use a mixed solution of hydrophobic multi-walled CNT and dimethylformamid (DMF) and fabricate a solution-processed CNT-PDMS composite film over a spherically concave substrate, i.e. a focal energy converter. As the solution process can be applied over a large area, we could easily fabricate the focal transmitter that focuses the photoacoustic output at the moment of generation from the CNT-PDMS composite layer. With this method, we developed photoacoustic energy converters with a large diameter (>25 mm) and a long focal length (several cm). The lens performance was characterized in terms of output pressure amplitude for an incident pulsed laser energy and focal spot dimension in both lateral and axial. Due to the long focal length, we expect that the new lens can be applied for long-range ultrasonic treatment, e.g. biomedical therapy.

  • PDF