• Title/Summary/Keyword: Pulse oximeter

Search Result 81, Processing Time 0.027 seconds

A Study on Learning Experiences and Self-Confidence of Core Nursing Skills in Nursing Practicum among Final Year Nursing Students (졸업학년 간호학생의 핵심기본간호술 학습경험과 수행자신감 조사연구: 실습교과를 중심으로)

  • Han, Aekyung;Cho, Dong Sook;Won, Jongsoon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.21 no.2
    • /
    • pp.162-173
    • /
    • 2014
  • Purpose: This study was done to identify learning experiences and self-confidence and to analyze nursing students' self-confidence according to learning experiences for core nursing skills (CNS). Method: Participants were 502 final year nursing students. Data were collected using a structured questionnaire and analyzed using descriptive statistics and t-test. Results: Over 60% of participants had practiced 15 items of the 24 CNS in the basic nursing lab (BNL). In clinical practice (CP), they had practiced five items but experienced only one item in a simulation lab (SL). Items with the highest confidence level were vital signs (4.69) followed by blood sugar test (4.60), pulse oximeter (4.38), and oral medication (4.12). Items with the lowest confidence level were blood transfusion (2.17) followed by enema (2.64) and indwelling catheterization (2.67). The group with CNS experience in the practice curriculum was generally more confident than the group with no experience. Self-confidences in some skills was significantly different depending on availability of SL, credits for BNL and CP, and presence of preceptors. Conclusion: Results indicate a need to develop practice education strategies such as changing the CP to practice-centered learning with preceptors and including well-designed SL to increase confidence of nursing students.

Reliable Measurement and Analysis System for Ubiquitous Healthcare (고신뢰 유비쿼터스 헬스케어 데이터 측정 및 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Kim, Jong-Jin;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.293-297
    • /
    • 2009
  • This paper describes a real-time reliable measurement and analysis system for ubiquitous healthcare based on IEEE802.15.4 standard. In order to obtain and monitor physiological body signals continuously, wearable pulse oximeter is designed in wrist that could used to measure oxygen saturation of a patient unobtrusively. The measured data was transferred to a central PC or server by using wireless sensor nodes via a wireless sensor network for storage and analysis purposes. LabVIEW server program was designed to monitor and process the measured photoplethysmogram(PPG) to accelerated plethysmogram(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.

  • PDF

Cerebral Oxygenation during Apnea in Preterm Infants: Effects of Accompanying Peripheral Oxygen Desaturation

  • Choi, Seo Hee;Lee, Juyoung;Nam, Soo Kyung;Jun, Yong Hoon
    • Neonatal Medicine
    • /
    • v.28 no.1
    • /
    • pp.14-21
    • /
    • 2021
  • Purpose: Premature infants have immature respiratory control and cerebral autoregulation. We aimed to investigate changes in cerebral oxygenation during apnea with and without peripheral oxygen desaturation in premature infants. Methods: This prospective observational study was conducted at Inha University Hospital. Near-infrared spectroscopy (NIRS)-monitored regional cerebral oxygen saturation (rScO2) and pulse oximeter-monitored peripheral oxygen saturation (SpO2) were assessed during the first week of life in 16 stable, spontaneously breathing preterm infants. Apneic episodes that lasted for ≥20 seconds or were accompanied by desaturation or bradycardia were included for analysis. The average rScO2 value during the 5-minute prior to apnea (baseline), the lowest rScO2 value following apnea (nadir), the time to recover to baseline (recovery time), the area under the curve (AUC), and the overshoot above the baseline after recovery were analyzed. Results: The median gestational age and birth weight of the infants were 29.2 weeks (interquartile range [IQR], 28.5 to 30.5) and 1,130 g (IQR, 985 to 1,245), respectively. A total of 73 apneic episodes were recorded at a median postnatal age of 2 days (IQR, 1 to 4). The rScO2 decreased significantly following apneic episodes regardless accompanied desaturation. There were no differences in baseline, nadir, or overshoot rScO2 between the two groups. However, the rScO2 AUC for apnea with desaturation was significantly higher than that for apnea without desaturation. Conclusion: Cerebral oxygenation can significantly decrease during apnea, especially when accompanied by reduced SpO2. These results add the evidence for the clinical utility of NIRS in monitoring premature infants.

Comparison of the anesthetic effects of 2,2,2-tribromoethanol on ICR mice derived from three different sources

  • Lee, Mi Ree;Suh, Hye Rin;Kim, Myeong Whan;Cho, Joon Young;Song, Hyun Keun;Jung, Young Suk;Hwang, Dae Youn;Kim, Kil Soo
    • Laboraroty Animal Research
    • /
    • v.34 no.4
    • /
    • pp.270-278
    • /
    • 2018
  • This study was conducted to compare the anesthetic effects of 2,2,2-tribromoethanol (TBE, $Avertin^{(R)}$) in ICR mice obtained from three different sources. TBE (2.5%) was intraperitoneally injected at three doses: high-dose group (500 mg/kg), intermediate-dose group (250 mg/kg), and low-dose group (125 mg/kg). Anesthesia time, recovery time, end-tidal peak $CO_2$ ($ETCO_2$), mean arterial blood pressure, heart rate, oxygen saturation ($SpO_2$), body temperature, pH, $PCO_2$, and $PO_2$ of the arterial blood were measured. Stable anesthesia was induced by all doses of TBE and the anesthesia time was maintained exhibited dose dependency. No significant differences in anesthetic duration were found among the three different strains. However, the anesthesia time was longer in female than in male mice, and the duration of anesthesia was significantly longer in female than in male mice in the high-dose group. The recovery time was significantly longer for female than male mice in the intermediate- and high-dose groups. In the ICR strains tested, there were no significant differences in the mean arterial blood pressure, $SPO_2$, arterial blood $PCO_2$, and $PO_2$, which decreased after TBE anesthesia, or in heart rate and $ETCO_2$, which increased after TBE anesthesia. In addition, body temperature, blood biochemical markers, and histopathological changes of the liver, kidney, and lung were not significantly changed by TBE anesthesia. These results suggested that ICR mice from different sources exhibited similar overall responses to a single exposure to TBE anesthesia. In conclusion, TBE is a useful drug that can induce similar anesthetic effects in three different strains of ICR mice.

Real-time Vital Signs Measurement System using Facial Image Data (안면 이미지 데이터를 이용한 실시간 생체징후 측정시스템)

  • Kim, DaeYeol;Kim, JinSoo;Lee, KwangKee
    • Journal of Broadcast Engineering
    • /
    • v.26 no.2
    • /
    • pp.132-142
    • /
    • 2021
  • The purpose of this study is to present an effective methodology that can measure heart rate, heart rate variability, oxygen saturation, respiration rate, mental stress level, and blood pressure using mobile front camera that can be accessed most in real life. Face recognition was performed in real-time using Blaze Face to acquire facial image data, and the forehead was designated as ROI (Region Of Interest) using feature points of the eyes, nose, and mouth, and ears. Representative values for each channel of the ROI were generated and aligned on the time axis to measure vital signs. The vital signs measurement method was based on Fourier transform, and noise was removed and filtered according to the desired vital signs to increase the accuracy of the measurement. To verify the results, vital signs measured using facial image data were compared with pulse oximeter contact sensor, and TI non-contact sensor. As a result of this work, the possibility of extracting a total of six vital signs (heart rate, heart rate variability, oxygen saturation, respiratory rate, stress, and blood pressure) was confirmed through facial images.

On an "Um~" Vocal Breathing to Relieve Stress When Wearing a Mask (마스크 착용시 스트레스 해소를 위한 "음~"발성호흡 연구)

  • Tian, Zhixing;Bae, Myung-Jin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.576-581
    • /
    • 2021
  • In the post-epidemic era, COVID-19 has not yet been fully controlled. Wearing masks is still the main means of epidemic prevention, and the negative effects brought by masks continue to continue. Wearing a mask for a long time can cause two problems. The first problem is hypoxia, and the other is an increase in psychological stress. To reduce the negative impact of masks, this paper proposes a new breathing mode. It is the "Umm~" vocal breathing mode, which simultaneously solves the two problems of hypoxia and increased stress. This paper explores the reasons why new breathing patterns can relieve stress. Explains the relationship between HRV and stress index and uses SDNN as an indicator to detect stress index to confirm the effectiveness of this breathing pattern. Experimental results prove that the "Umm~" vocal breathing mode can not only relieve the stress induced by wearing a mask. And when not wearing a mask, it can also be used to relieve daily stress. This method that anyone can easily implement should be more popularized.

Deep Learning-based Real-time Heart Rate Measurement System Using Mobile Facial Videos (딥러닝 기반의 모바일 얼굴 영상을 이용한 실시간 심박수 측정 시스템)

  • Ji, Yerim;Lim, Seoyeon;Park, Soyeon;Kim, Sangha;Dong, Suh-Yeon
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.11
    • /
    • pp.1481-1491
    • /
    • 2021
  • Since most biosignals rely on contact-based measurement, there is still a problem in that it is hard to provide convenience to users by applying them to daily life. In this paper, we present a mobile application for estimating heart rate based on a deep learning model. The proposed application measures heart rate by capturing real-time face images in a non-contact manner. We trained a three-dimensional convolutional neural network to predict photoplethysmography (PPG) from face images. The face images used for training were taken in various movements and situations. To evaluate the performance of the proposed system, we used a pulse oximeter to measure a ground truth PPG. As a result, the deviation of the calculated root means square error between the heart rate from remote PPG measured by the proposed system and the heart rate from the ground truth was about 1.14, showing no significant difference. Our findings suggest that heart rate measurement by mobile applications is accurate enough to help manage health during daily life.

The Study on the Relationship Between the Duration of Chest Vibration prior to Endotracheal Suctioning and the Changes in Oxygen Saturation in Low-Birth-Weight Infants (저체중아에 있어 기관내 흡인전 흉부진동법의 기관과 산소포화 변화간의 관계 연구)

  • Ahn, Young-Mee
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.3
    • /
    • pp.597-607
    • /
    • 1995
  • 1960년대 이후 인공호흡기(mechanical ventilator)의 보급과 최근 의료과학의 발달, 간호의 질적 향상의 결과로 저체중출생아를 포함한 고위험 신생아의 생존율이 높아져왔다. 호흡장애증후군(RDS)은 일차적으로 폐포의 완전한 확장을 위해 필요한 계면활성물질(surfactant)의 부족, 미발달된 심폐기능에 의한 병리적 현상으로 저체중아의 가장 큰 원인이 되어왔다. RDS로 인해 인공호흡기에 의존해 있는 저체중아의 경우 적절한 산소공급과 이를 위한 호흡의 유지는 치료의 가장 큰 핵심이 되며, 이를 위한 기관내 흑은 비인두 흡인 (nasopharyngeal suction)은 신생아 중환자실(NICU)의 가장 중요한 간호행위가 되어왔다. 인공호흡기를 위한 기관삽관은 그 자체가 기도의 성모운동을 방해하고 기침반사를 억제시켜 폐 분비물의 효과적 배출을 억제하며, 특히 저체중아의 경우 조산과 관련하여 미발달된 흥곽운등과 심폐기능은 폐분비물의 이동을 저해하는 요소이다. 따라서 기도내의 분비물의 이동을 효과적으로 하여 흡인 시에 최대한의 효과를 돕기 위해 흥곽 물리요법(chest physiotheraphy : CPT)의 한 형태인 흉곽진동법 (Chest Vibration : CV)가 행해져 왔다. 그러나 저체중아를 위한CV의 임상적 적용은 그 대상의 생리적 특성, CV의 적용부위(site)와 기간(duration)에 대한 과학적 근거 없이 만성감염이나 폐질환을 가진 성인이나 cystic fibrosis환자를 위한 CV protocol을 무분별하게 채택하여 저체중아에게 행하여져 왔다 이에 본 연구자는 저체중아에 대한 CV의 안전성을 평가하고, 이에 기초하여 저체중아에게 바람직한CV의 형태를 알아보고자 본 연구를 시작하였다. 연구설계는 CV의 안전성을 평가하기 위한 실험연구이다. CV의 안전성은 RDS치료의 가장 일차적 목표인 oxygenation변화에 의해 평가될 수 있으므로, 본 실험 연구에서는 Pulse oximeter에 의해 계속적으로 측정된 산소포화 변화(oxygen saturation change)를 측정하였다. 실험대상은 미국동부에 위치한 대학병원의 NICU에 입원하여 RDS와 관련된 호흡장애로 인공호흡기에 의존해 있는 10명의 저체중아였다. 인공호흡기에 의존된 모든 저체중아는 Pulse oximeter와 심폐기능 측정기(cardiopulmonary monitor)에 의해 산소공급과 호흡상태가 계속 측정되고 있었다. 실험대상의 평균 출생시 몸무게는 평균 1,3050gm(SD=580.6)이었고, 임신월령 은 평균 28.6주(SD=3.1)였다. RDS가 그들의 일차적 진단명이었고, 그중 4명은 pneumonia, atelectasis의 합병증을 가지고 있었다. 10명중 6명은 intermittent mandatory ventilation(IMV)의 형태로, 4명은 continuous positive airway pressure(CPAP)의 형태로 인공호흡기에 의존되어 있었고 CV시의 FiO2는 평균 42.3(SD=21.2)였다. CV는 중환아용 소형진동기 (minivibrator)를 이용해 가각 10명 의 간호사에 의해 행하여 졌고, 최소 22초에서 최대 100초 동안 실시되었다. 50%의 간호사는 30초에서 40초간 CV를 실시하였으며, CV의 적용부위도, 전후 흉곽부위, 혹은 병변이 있는 좌 우측, 흑은 양쪽 흉벽 등으로 다양했고, 적용방법도 원형으로 돌려가며(circular motion), 혹은 아래에서 위로, 혹은 아무런 기준없이 간호사의 기호에 따라 다양하게 적용되었다. 산소포화의 변화는 CV가 행해지기 전.후로 5초동안 관찰되었다. 연구의 결과, 산소포화 변화는 비 모수통계(non parametric statistics)의 일종인 Matched Paired Wilcoxon test로 분석 한 결과 CV후에 3%의 감소를 보였다(P<.05). 저체중아에 있어 산소포화의 3%감소는 임상적으로 중요한 의미가 없다고 사료되어지며, 실제 흡인전의 과도호흡에 의해 CV를 행하기 이전의 산소공급수준으로 돌아 왔다. CV실시 기간과 산소포화와의 상관관계는 비 모수통계인 Spearman rho correlation coefficient를 이용하여 분석하였는데, 이 두 변수는 서로 관계가 없는 것으로 나타났다(P>.05) 또한 CV와 흡인 후에 각각의 간호사들에게 CV를 필요로 한 저체중아의 기준, 적용부위, 기간, 방법등에 대한 기준을 물었으나 대상의 특성에 따른 간호사정에 의존하기보다는 간호사 각자의 선호하는 방법이나 습관에 라 행하는 것으로 나타났다. 결론적으로 CV와 산소포화 변화와의 관계, NICU에서 관찰된 CV의 임상적 적용을 기초로 저체중아에게 안전한 CV protocol은 신생아용 소형 진동기를 이용하여, 양쪽 흉곽의 늑골하측 변연 부위(low lateral costal margin)에서 시작하여 흉골 중앙부위 방향으로 30초 동안 진동기를 적용하는 것이 좋은 것으로 나타났다. 이에 CV의 효과를 평가하기 위한 보다 과학적인 접근방법으로, CV와 흡인의 결과인 가래(sputum)에 대한 연구를 제언하는 바이다.

  • PDF

A SURVEY OF SEDATION PRACTICES IN THE KOREAN PEDIATRIC DENTAL OFFICE (어린이의 치과치료시 약물에 의한 진정요법 사용에 대한 실태조사)

  • An, So-Youn;Choi, Byung-Jai;Kwak, Ji-Youn;Kang, Jeong-Wan;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.444-453
    • /
    • 2005
  • Sometimes the dentists encounter a child who can not be treated with traditional behavior management techniques (for example, reward, restraint, Tell-Show-Do, familialization). In such a case, the dentists use sedation technique. Recently, in Korea, the use of sedation by pediatric dentists is increased. But, the guideline and survey of sedation is very insufficient. Now, we need a survey of sedation practice in Korea. We carried out research on the actual condition about sedation with a questionaire to pediatric dentists in Korea. Followings are the conclusions 1. Sixty six percent of pediatric dentists use sedative agents in their practice. In this study, using sedation shows an increase as compared with the past. 2. Determinative factors of using sedation were orderly behavior management, number of visiting, guidian's opinion, amount of treatment, general condition. 3. Distribution of ages in patients sedated with agents was orderly 3 years, 4-5 years, under 2 years, 6-10 years, more than 10 years. 4. Particular sedative drugs were chloral hydrate 60-70mg/kg, hydroxyzine 10-40mg/kg(25mg/kg), and oral route was the most favorable route. 5. Observation of skin and nail color, pulse oximeter were the most frequently utillized monitoring method during sedation. 6. Only fifty six percent of pediatric dentists complete the cardiopulmonary resuscitation course.

  • PDF

Safety and Efficacy of Submucosal Midazolam When Combined with Oral Chloral Hydrate, Hydroxyzine and Nitrous Oxide Sedation by using Houpt's Scale (Midazolam을 구강 점막 하로 병용 투여한 진정법의 안정성과 Houpt Scale을 이용한 진정효과에 대한 연구)

  • Park, Mi-Koung;Kim, Yun-Hee;Jung, Sang-Hyuk;Beak, Kwang-Woo
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.6 no.2 s.11
    • /
    • pp.103-112
    • /
    • 2006
  • Background: The purpose of this study was to compare the clinical safety and effect with and without additional submucosal midazolam to oral chloral hydrate and hydroxyzine when used for pediatric conscious sedation in a clinical dental environment. Methods: Thirty one cases of pediatric conscious sedations were performed in this study. Selection criteria included good health (ASA I), under 6 years old, 20 kg of body weight, uncooperative behavior and the need for sedation to receive dental treatment including anesthesia and restorative or surgical procedure for at least two teeth. In each visit, patients were randomly assigned into one of two groups; CH group: chloral hydrate (60 mg/kg), hydroxyzine (1 mg/kg), CH-M group: chloral hydrate (60 mg/kg). hydroxyzine (1 mg/kg) and submucoal midazolam (0.1 mg/kg). 50% nitrous oxide-oxygen was maintained during the sedation period Sedations were monitored using a pulse oximeter for estimating pulse rate (PR) and percutaneous oxygen saturation ($SpO_2$). Behavior response rated using Houpt's scale and need of restraint was assessed every 2 minutes through 30 minutes of operative procedure reviewing the videotape recording. Evaluation of overall behavior success was performed using modified overall behavior rate of Houpt's scale. Data was analyzed using t-test. Results: PR and $SpO_2$ for both groups remained within the normal values. The mean scores for sleep and movement of CH-M group were higher than those of CH group (P < 0.05). There were no significant difference in mean score for crying between two groups. The mean scores of overall behavior of CH-M group was higher than those of CH group (P < 0.01). Reinstraint of CH-M group was less required than that of CH group (P < 0.05). Conclusions: Oral chloral hydrate (60 mg/kg) and hydroxyzine (1 mg/kg) combined with submucosal injection of midazolam was safer and showed more improved sedation effect than oral chloral hydrate (60 mg/kg) and hydroxyzine (1 mg/kg) without midazolam for sedation of pediatric dental patients.

  • PDF