• 제목/요약/키워드: Pulse diagnosis analysis

검색결과 131건 처리시간 0.025초

소아맥진(小兒脈診)의 특성(特性)에 대한 소고(小考) (A study on The Characteristic of Traditional Pediatric Pulse Diagnosis)

  • 백유상
    • 대한한의학원전학회지
    • /
    • 제27권1호
    • /
    • pp.111-122
    • /
    • 2014
  • Objective : The region, observation period, figuration of pulse, pulse frequency, process of diagnosis and related diagnostic methods in traditional pediatric pulse diagnosis were studied in this article. Method : The articles related to traditional pediatric pulse diagnosis in Traditional medical classics, and analysis to the characteristics of it was done, then lastly, the principle of pulse manifestation and the meaning of application to modern times were considered. Result & Conclusion : It is difficult to catch the figuration of pediatric pulse because of dynamic change of body conditions, fast heartbeat and narrow region of pulse. Therefore, the pulse diagnosis appropriated for children have been developed and combined with the special diagnosis methods, for example, palpation of forehead and observation of index finger. The traditional pediatric pulse diagnosis is done with just one finger palpation in the period of 3 to 5 years old to identify the speed, length, size and height of pulse. The standard average of pulse frequency is 7~8 par breath in the period of 3 to 5 years old according to traditional medical classic.

${\cdot}$ 침맥 진단에 유용한 맥상 파라메터 및 대표맥상 분석 (Analysing of pulse wave parameter and typical pulse pattern for diagnosis in floating and sinking pulses)

  • 이유정;이전;최은지;이혜정;김종열
    • 한국한의학연구원논문집
    • /
    • 제12권2호통권17호
    • /
    • pp.93-101
    • /
    • 2006
  • Pulse feeling is one of the most important diagnosis method in Oriental medicine. But it is not easy to make an objective and standardized diagnosis. In this study, we found how to quantify diagnosis. Specially dally the high practicality in clinic, we search some parameters especially well-related to floating and sinking pulse by statistic analysis. By extension, we find the pulse patterns of the floating and sinking pulse. We choose 15 subjects diagnosed as floating pulse and 15 subjects diagnosed as sinking pulse by oriental doctors. And their pulse signals were acquired by Pulse analyzer which has piezoresistive pressure sensor. For the quantification of the floating and sinking pulse, at first, we examined the parameters which were highly correlated with oriental doctor's diagnosis. And then we derived pulse patterns of the floating-sinking pulse from preprocessed signal and its ensemble average. We also looked trend variation (PH-Curve) between contact and pulse pressure. As a result, statistically there is the biggest difference between contact pressure, the maximum pulse pressure, diastolic area (Ad) and floating and sinking data. Through the PH-Curve, which represented the relationship between contact and pulse pressure, we could divide the floating and sinking pulse clearly. As a basic research of pulse diagnosis algorithm, we can contribute to select essential parameters in diagnosis algorithm And using these diagnosis method, we expect to find typical pulse patterns and some useful parameters about other pulses like slow/rapid, large/fine pulse and so on. We hope that this study will contribute pulse objectification.

  • PDF

여성 불임환자의 맥진특성 연구 (A Study on Characteristics of Pulse Diagnosis in Infertile Women)

  • 유정은;장새별;유동열
    • 혜화의학회지
    • /
    • 제23권2호
    • /
    • pp.15-21
    • /
    • 2015
  • Objective : The purpose of this study is to demonstrate the characteristics of pulse diagnosis in infertile women. Methods : We have studied 38 women infertility patients in the Dunsan oriental hospital by using pulse diagnostic device. Pulsation and pulse types have been analyzed with variables of infertility factors. Statistical analysis was performed by adopting descriptive and inferential tests. Results : Both right and left chi parts were shown different from other parts. In small intestine and gall bladder showed significantly different pulsation according to the infertility factor. Short pulse, fine pulse, skipping pulse, shallow pulse and deep pulse were often representative pulse types for the main organs of woman infertility. In Triple energizers showed significantly different shallow pulse type according to the infertility factor. Conclusion : The results corresponded closely with previous literature on pulse diagnosis about infertile women.

  • PDF

정상인에게서 측정되는 인영촌구맥의 경향성 분석 (Analysis of Inyoung-Chongu Pulse Measured on Normal People)

  • 최찬헌
    • 동의생리병리학회지
    • /
    • 제24권1호
    • /
    • pp.158-164
    • /
    • 2010
  • The aim of this study is to examine the reliability of Inyoung-Chongu pulse diagnosis by analyzing Inyoung-Chongu pulse measured on normal people. I measure the size of Inyoung & Chongu pulse, ratio of Inyoung to Chongu, and ratio of Chongu to Inyoung on 50 normal people. Inyoung pulse of normal people is $6.44{\pm}1.62$ volt and Chongu pulse of normal people is $6.81{\pm}1.70$ volt. The ratio of Inyoun to Chongu is $1.03{\pm}0.50$ and that of Chongu to Inyoung is $1.12{\pm}0.41$. Through this experiment, I conclude that the Inyoung-Chongu pulse diagnosis is reproducible on normal people and can develop pulse diagnosis device through comparison between Inyoung and Chongu pulse.

맥상기를 통한 요골동맥 맥진법의 맥파분석 - 좌관부위 맥파요인을 중심으로 - (Study on the Waveform Analysis of Radial Artery Pulse Diagnosis Using Pulse Meter and Analyzer - the Waveform Analysis of Left KWAN Pulse Dignosis -)

  • 김경철;이정원;류경호;박동일;신우진;강희정
    • 동의생리병리학회지
    • /
    • 제23권1호
    • /
    • pp.186-191
    • /
    • 2009
  • In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research. As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(CHON, KWAN, CHEOG). First of all, in this research, we did the experiment of the study on the waveform analysis of radial artery(left KWAN) pulse dignosis by using 3 dimension pulse meter and analyzer (3D MAC). As a result. we extracted the seven measurement fluents : energy(E), size of cycle(h1), size of reflection cycle(h2), time of reflection cycle(t2), time of contraction (t4), width of cycle(w), area of waveform(A) by the statistically reasonable differences. We expect that the seven measurement fluents contribute to divide the situation through the results of waveform analysis of radial artery.

맥파자동진단을 위한 하드웨어의 설계 및 특성점 검출 알고리즘에 관한 연구 (A Study on the Significant Point Detection Algorithm and Design of Hardware for Pulse Automatic Diagnosis)

  • 이준영;이정환;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2255-2258
    • /
    • 1998
  • Method of diagnosis in oriental medicine, the unbalance of the physiological function of the five viscers and six bowels of the human body is determined from time immemorial with the condition of blood circulation which is performed through blood vessels by the vitality of the heart. In oriental medicine, treatment is largely attempted by adjusting this unbalance. The analysis of pulse wave, which mainly measures the changes in blood flows, is to evaluate the shapes of a pulse wave rather than the quantitative changes like rates and strength of the pulse. This paper presents the development of Hardware System and Pulse Diagnosis Algorithm for automatic diagnosis of the pulse wave. This system makes the precise diagnosis and the objective recording possible.

  • PDF

문헌을 통한 맥상의 물리적 요소 분석 (Analysis of Physical Quantification of Pulse Types by Pulse Diagnosis Literatures)

  • 유현희;이시우;이전;이유정;김종열
    • 동의생리병리학회지
    • /
    • 제21권6호
    • /
    • pp.1381-1387
    • /
    • 2007
  • Pulse diagnosis that is one of important examination methods in traditional oriental medicine has been investigated for the standardization in many ways. Pulse analyzer device and clinical studies have been tried for this purpose. Additionally, literature study has significance for this standardization. In this study, we analyzed pulse types in literatures from the viewpoint of physics. We refered to Maijing, Maijue, siyanjuyao, Binhumaixue, Yixuerumen, zhenjiazhengyan. We established some physical factors for analysis. This factors that can be detected through pulse analyzer are depth, speed, power, width, and length. In this study, we defined 18 kinds of pulse types among 28 total types by physical factors. Furthermore, 6 kinds of pulse types were classified as basic pulse from these. The results of this study will improve the pulse analyzer to detect these pulse types.

통계분석을 통한 한의 맥진에 유용한 파라미터 도출: 부침맥을 중심으로 한 예비연구 (Proposal of pulse parameter useful for pulse wave analysis in oriental medicine: Preliminary study on floating and sinking pulses)

  • 이전;이유정;이혜정;최은지;김종열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.244-246
    • /
    • 2006
  • In this study, we search some parameters well-related to floating-sinking pulse by statistical analysis, because these pulses are frequently used in clinic. Pulse signals were acquired by 3D pulse analyzer and 30 subjects consist of 15 people diagnosed as floating pulse and 15 people diagnosed as sinking pulse by oriental doctors who have over 5 years clinical experience. Then, we made a representative beat template for each subject and, through a peak detection algorithm, we calculated several pulse parameters. To find the parameters related to floating-sinking pulse, we performed statistical testing with 17 parameters through the independence sampling, t-test. As a result, there is the biggest difference between pressure, the maximum pulse pressure, diastolic area(Ad) and float-sink data. (p < .05).

  • PDF

웹기반 임상 맥파 데이터 분석 시스템에 관한 연구 (The Study on the Web-Based Analysis System of Oriental Pulse Waveform)

  • 이준영
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.9-12
    • /
    • 2012
  • This paper analyzes a web-based clinical management system and conducts research on the pulse. Pulse analysis and the clinical study management system proposed by the web-based research holds significance in that it improves the objectivity and accuracy of pulse diagnosis. In particular, exact data must be analyzed through the clinical interpretation of these studies. Eventually oriental pulse standardization work will be continuously sustained. The findings of this study will help achieve remote diagnosis and consultation and updating of database. Research must be expanded to the development of telemedicine technology to create u-Health that will lead this present era.

중의사의 맥진기 인식에 대한 통계 분석 연구 (The statistical analysis for cognizance on the Chinese oriental medical doctor of the pulse meter-analyzer)

  • 김경철;김종환;신우진;이해웅;박주연;홍상민;두승희;강희정;조영일
    • 대한한의진단학회지
    • /
    • 제13권2호
    • /
    • pp.88-116
    • /
    • 2009
  • Background : EBM (the evidence based medicine) is the direction of the development for oriental medicine. The pulse meter-analyzer is the important part to standardize the pulse diagnosis. When we set up the direction of the study on the pulse meter-analyzer, the awereness about the pulse meter and analyzer of the clinical oriental medical doctors as consumers is very important. Objectives : In order to prepare for the mutual study and the export strategy on the pulse meter-analyzer of Korea and China, the attitude of the study and the grasp of the awereness about the pulse meter-analyzer of the Chinese medical doctors are very important. Methods : We developed the several items as the important factor of the development of the pulse meter and analyzer. They were translated by chinese medical doctor. The investigation for demend was conducted during 3 months in Guangzhou City, Guangdong Province, China. The results of the investigation was done the statistical method of frequency analysis, Chi-squared test, correspondence analysis. Results : The most important differentiation of symptom is the symptom of JANG-BU(臟腑). The method of the utility in the pulse diagnosis is Chon-Gu (寸口) pulse diagnosis and the research on Chon-Kwan-Cheok(寸關尺) is the most important measurement factor. And the typical the old pulse is the little-fine weak pulse. The pulse meter-analyzer is most suitable to the diagnosis of the hypertension and the arteriosclerosis. Conclusion : The development of the pulse analyzer including the requests of Korean and Chinese medical doctors is very important. Specially the researches on the influence factors of the traditional diagnosis and the environment of the measurement are important for developing the pulse analyze.

  • PDF