• Title/Summary/Keyword: Protection Termination

Search Result 30, Processing Time 0.022 seconds

Development of Ground Impedance Measuring Instrument for Lightning Protection System (뇌보호 설비를 위한 접지임피던스 측정기 개발)

  • Lee, Tae-Hyung;Cha, Sung-Chul;Earn, Ju-Hang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.194-195
    • /
    • 2006
  • This study evaluated the impedance characteristics of earth termination system and developed a variable frequency-typed inverter (measuring tool) for the utilization in ground design for lightning protection. The variable-frequency-typed inverter were composed of rectification part, voltage adjuster, IGBT controller and measuring part. Meanwhile, the square wave signal of variable frequency converted its frequency up to lightning surge band by using an IGBT after rectifying an alternating current (AC). It conducted performance evaluation of ground impedance of actual earth termination system by using the developed measuring tool for ground impedance and confirmed that such impedance-oriented performance evaluation was effective in the design of lightning protection.

  • PDF

Development of Components and Installation Techniques of Air-termination System on the Metal Roof in Apartments (공동주택 금속기와지붕 수뢰시스템의 자재 및 시공기법 개발)

  • Lee, Ki-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.109-115
    • /
    • 2011
  • Apartments covered with a metal roof made from galvalume steel are prevailing due to their economic and technical advantages. The metal roof, however, has disadvantages in terms of the installation of air-termination system on it because of the slip thickness of the metal roof. In this paper, the impacts of the lightning current to a metal roof were verified experimentally with a short lightning impulse current (10/350[${\mu}s$]). Also, we developed various supporters of air-termination conductor for the metal roof and verified their excellent workability and economical strength through field application test.

Analysis on Lightning Overvoltage According to Lead Length of Surge Arrester for Underground Cable Outdoor Termination Protection at C/H Tower (C/H 철탑 종단접속함 보호용 피뢰기 리드선 길이에 따른 뇌과전압 분석)

  • Jung, Chae-Kyun;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.257-263
    • /
    • 2016
  • This paper describes the lightning arrester transients in cable head termination. The installation references of cable head tower and lightning arresters are firstly reviewed, then the performance of lightning arrester operation is also evaluated based on lightning overvoltage analysis by the change of grounding lead cable length. This paper finally proposes the optimal length of grounding lead cable at the cable head termination. The limited lightning current is also proposed according to the change of grounding lead cable length. The results will contribute to protecting insulation breakdown failure against lightning surge at the terminations and joints.

Considerations in Down-conductor System and Earth-termination System Design of Apartments (공동주택에서의 인하도선시스템과 접지시스템 설계에 대한 고찰)

  • Lee, Ki-Hong;Lee, Jae-Bok;Chang, Sug-Hun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.54-58
    • /
    • 2006
  • This paper deals with primary consideration in down-conductor system and earth-termination system design of apartments. For down-conductor system, steelworks within reinforced concrete apartment structures have the electrical continuity, however, lashing is not suitable for lightning-current-carrying connections. So this paper suggest that the additional dedicated conductors should be installed and they are should be lashed to the reinforcement steel. Also this paper suggested the foundation earth electrode and global earth system as the earth-termination system of the apartments. But perfect bonding system is essential in lightning protection system to avoid life hazard and to protect electronic equipments.

  • PDF

A Study on Electrical Accident of Distributing Cable Termination with Simulated Badness Construction (평가시공불량을 모의한 배전급 케이블 종단부의 전기적 사고 연구)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun;Kim, Young-Seok;Kim, Sun-Gu;Baek, Seung-Myeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.465-470
    • /
    • 2008
  • This paper introduces experimental investigates of an electrical accident of the distributing cable termination with simulated badness construction. We prepared two termination kites, one is built-up type, the other is heat contraction type. Also, we manufactured cable termination that have simulated defect by badness construction and measured their insulation characteristics such as ac (35kV, 1min) and impulse (95kV, $1.2{\times}50{\mu}s$) withstand test. The influence of defects such as thickness and the gap between stress-con of housing and semi-conductor on insulating properties of the termination have been studied. The thickness decrease of insulator decreases ac breakdown strength. Dielectric breakdown traces of insulator that is damaged by knife displayed other shape. The gap of between housing and semiconductor deteriorates dielectric strength of insulator seriously.

  • PDF

A Novel Approved Mathematical Equation for Lightning Protection Angle

  • Singhasathein, Arnon;Rungseevijitprapa, Weerapun;Pruksanubal, Aphibal
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.1021-1029
    • /
    • 2018
  • During the past few decades, the lightning protection angle (${\alpha}$) has been proposed through several technical matters, namely graphical technique, numerical data and mathematical equation respectively. Nevertheless, these techniques are very complicated, and are difficult to utilize because they also contain several constraints practically. Hence, this paper proposes a novel equation of the lightning protection angle, which is a simple correlation, concise and easy to be implemented. Furthermore, the reliable result of this equation can confirm accuracy through comparative analysis with all previous techniques. As a result, these solutions are altogether equivalent. This novel equation can analyze the lightning protection angle of the vertical air termination system installed at the vertex of the royal pagoda in a Khema-pirataram temple which is at high risk due to lightning flashes.

A Framework for OAM in OBS Networks (OBS 네트워크의 OAM 기본 체제)

  • Shin Jong-Dug
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.1B
    • /
    • pp.41-51
    • /
    • 2004
  • Operation and maintenance (OAM) in optical burst switching (OBS) networks has not yet been addressed even though OBS has been gaining research interest in recent years. In this paper, we defined five OBS functions such as Burst Termination (BT), Burst Transmission (BTX), Burst Switching (BSW), Routing and Switching Control (RSC), and Protection and Restoration (PAR). A functional model for OBS networks and an OAM architecture are designed to meet the operational requirements. We present the first framework to realize OAM in OBS networks, including OAM activities, OAM-capable OBS nodes such as ingress edge, core, and egress edge nodes, OAM information and communication models and protocols. A number of examples of possible network failures are pointed out and the corresponding reactions to these using the proposed OAM architecture are presented.

Linear Unequal Error Protection Codes based on Terminated Convolutional Codes

  • Bredtmann, Oliver;Czylwik, Andreas
    • Journal of Communications and Networks
    • /
    • v.17 no.1
    • /
    • pp.12-20
    • /
    • 2015
  • Convolutional codes which are terminated by direct truncation (DT) and zero tail termination provide unequal error protection. When DT terminated convolutional codes are used to encode short messages, they have interesting error protection properties. Such codes match the significance of the output bits of common quantizers and therefore lead to a low mean square error (MSE) when they are used to encode quantizer outputs which are transmitted via a noisy digital communication system. A code construction method that allows adapting the code to the channel is introduced, which is based on time-varying convolutional codes. We can show by simulations that DT terminated convolutional codes lead to a lower MSE than standard block codes for all channel conditions. Furthermore, we develop an MSE approximation which is based on an upper bound on the error probability per information bit. By means of this MSE approximation, we compare the convolutional codes to linear unequal error protection code construction methods from the literature for code dimensions which are relevant in analog to digital conversion systems. In numerous situations, the DT terminated convolutional codes have the lowest MSE among all codes.

A Study on Accident Pattern of Distributing Cable Termination Considering PL Law Environment (PL법 환경을 고려한 배전 케이블 종단부의 사고 유형 연구)

  • Baek, Seung-Myeong;Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Young-Seok;Kim, Sun-Gu;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.319-322
    • /
    • 2008
  • This paper introduces experimental investigates of an accident pattern for the distributing XLPE cable terminations considering PL law environment. The influence of defects such as thickness and length decrease of XLPE, the impurity on XLPE and the gap between stress-con of housing and semi-conductor on insulating properties of the termination have been studied. The thickness and length decrease of XLPE decrease ac breakdown strengths. Dielectric breakdown traces of XLPE that is damaged by knife displayed other shape. The gap of between housing and semiconductor deteriorates dielectric strength of XLPE seriously.

  • PDF

Analysis of Health and Welfare Support for Children Who Have Ended Protection in Korea - Focused on the case of Cheonan city - (국내 보호종료아동 보건복지 지원실태 분석 -천안시 사례를 중심으로-)

  • YU, TAE GYU
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.115-119
    • /
    • 2022
  • According to the 「Child Welfare Act, Article 16(1)」, when the age of a child reaches 18, he or she is discharged from prison. However, in order to prepare an effective support posture from the central government and local governments, a clear fact-finding survey on children who have completed protection is necessary. Therefore, in this study, the most basic questionnaire on housing, health, education, employment, and social relations of children living in Cheonan City after completion of protection is required. An investigation was conducted. As a result, the housing and social relationship of children living in Cheonan city were good compared to children living in Cheonan city compared to children who completed protection nationwide. Therefore, it was found that it is urgent to establish a close cooperation system with related organizations in this regard.