• Title/Summary/Keyword: Protection Standards

Search Result 666, Processing Time 0.023 seconds

A Study of Protection Profile and Analysis of Related Standard for Internet Banking Systems (인터넷 뱅킹 시스템 관련 표준 분석 및 보호프로파일 개발에 관한 연구)

  • Jo, Hea-Suk;Kim, Seung-Joo;Won, Dong-Ho
    • The KIPS Transactions:PartC
    • /
    • v.17C no.3
    • /
    • pp.223-232
    • /
    • 2010
  • Due to the advance of Internet, offline services are expanded into online services and a financial transaction company provides online services using internet baning systems. However, security problems of the internet banking systems are caused by a lack of security for developing the internet banking systems. Although the financial transaction company has applied existing internal and external standards, ISO 20022, ISO/IEC 27001, ISO/IEC 9789, ISO/IEC 9796, Common Criteria, etc., there are still vulnerabilities. Because the standards lack in a consideration of security requirements of the internet banking system. This paper is intended to explain existing standards and discusses a reason that the standards have not full assurance of security when the internet baning system is applied by single standard. Moreover we make an analysis of a security functions for the internet baning systems and then selects the security requirements. In this paper, we suggest a new protection profile of the internet baning systems using Common Criteria V.3.1 from the analysis mentioned above.

Development of a Surge Protective Device for Computer Network to International Standards (국제규격 대응 컴퓨터 네트워크용 서지방호장치 개발)

  • Park Dae-won;Song Jae-yong;Han Joo-sup;Kil Gyung-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.6
    • /
    • pp.1253-1259
    • /
    • 2005
  • This paper dealt with the development of surge protection devices (SPDs) that can protect high speed computer network devices from overvoltages caused by switching operations or lightning surges. The designed SPD is a form of hybrid circuit which is composed of a gas tube having large current diverting capability, high response bi-directional avalanche diodes, and fast recovery diodes to reduce insertion loss on high frequency domain. Surge protection and signal transmission characteristics of the fabricated SPD was tested according to the international standards, IEC 61000-4-5 and IEC 61643-21. From the test results, the SPD is satisfied with the international standards and the high cut-off frequency was 204 MHz. Also, the SPD showed a good performance without an insertion loss on a field test of 100 Mbps class Local Area Network.

A Study on Effective Fire Countermeasures for Facilities for the Elderly and Children (노유자시설의 효율적인 화재 대응방안에 관한 연구)

  • Hwang, Euy-Hong;Choi, Han-Bit;Choi, Doon-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.107-114
    • /
    • 2020
  • With the development of the national industry, the importance of the elderly and children such as the elderly, disabled, and children is recognized. Similarly, the number of facilities for the elderly and children is increasing. Fires at facilities for the elderly and children cause heavy casualties. In response to these events, it is essential to activate fire alarms promptly and accurately and to secure evacuation routes. In this study, the laws and statistics related to facilities for elderly and children were reviewed, and problems with legal terms-such as elderly, children, others, unwanted alarm of fire alarm systems, blind spots of fire compartment standards, securing evacuation routes, and absence of standards for life safety rescue organizations-were identified. As an improvement measure, the legal definitions of similar terms-such as elderly, children, unwanted alarm checklist, and establishment of standards for fire prevention compartment-and introduction of other terms-evacuation elevators, the establishment of standards for life-safety rescue organizations, and provision of flame retardation objects for evacuees-were proposed.

The Globalization Trend of Railway Signalling Safety Standards and its Counterplans (철도신호 안전성 규격의 세계화 추세와 우리의 대응)

  • 김종기;조연옥;이종우;정의진
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.486-491
    • /
    • 2002
  • As the European Union has strengthened and computerized signalling systems have been widely used, the European common standards for the safety of railway signalling systems such as EN 50126, EN 50128, ENV 50129, EN 50159 began to be published from 1996 in CENELEC. At that time, a safety guideline, 'Safety Guidelines for Computerized Train Control and Protection Systems' was published in Japan. The Korean National Railroad also published a safety recommendation for the train control systems with taking into account the Korean railway conditions. Now the preparations for IEC/TC9 Standards are well underway and these standards correspond to CENELEC Standards referred above. These movements and activities are to cope with many technical and operational changes and to reflect the globalization trend of railway sectors along with the computerization of signalling devices. In this connection, this paper studies the globaliztion trend in the safety standards for railway signalling systems and discusses the counterplans for the trend.

  • PDF

Automatic Fire Detector Spacing Calculation for Performance Based Design (성능위주설계를 위한 화재감지기배치의 공학적연구)

  • Park, Dong-Ha
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2010
  • Placement method for fire detectors prescribed in current fire safety regulation is just about placing a prescribed number of detectors according to the areas. However, this regulation has no scientific basis and standards from foreign countries are just introduced and fire detectors are installed complying with them. There are two standards in designing fire protection systems; Prescriptive-Based Design that follows stipulated regulations like fire safety standards and Performance-Based Design based on engineering knowledge such as fire dynamics, structural dynamics, mechanics of materials, fluid mechanics, and thermo dynamics. Recently, Fire Protection System Construction Business Act was revised so that fire protection systems can be designed using Performance-Based Design method ('05. 8. 4), though the method has not activated until now. In addition, the enforcement decree defines the range for specific objects of fire protection to which Performance-Based Design is applied ('07, 1. 24). At the moment, by manufacturing simulator so that formulas can be introduced and calculated with software in order to install fire detector of automatic fire detection systems keeping optimized distance, comparing the results with the state of fire detector placed according to Performance-Based Design and analyzing them, this study was intended to settle Performance-Based Design method in the future.

Field Test for Absorption Energy and Displacement of Rockfall Protection Net (낙석방지울타리 망의 변위량 및 성능검증을 위한 실물낙석시험)

  • Seo, JinHyuk;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.12
    • /
    • pp.17-21
    • /
    • 2020
  • Over 60% of South Korea's land consists of mountainous topography, and recently, due to earthquakes, localized heavy rains and road development, the risks of rockfalls are getting higher. As of now, rockfall prevention facilities are being constructed in 70% of Korean roads cut slope and rockfall protections account for about 20% of them. Rockfall protection's supporting capacity is defined by combining performance of wire mesh, pillars and wire ropes. For the existing constructed rockfall protection, standards of pillars that can absorb 48~61 kJ amount of energy, wire ropes and wire mesh are presented in Guidelines for the installation and management of traffic safety facilities, Rockfall prevention facilities by Ministry of Land, Transport and Maritime Affairs (2008). However, each factor's correlation of absorption energy is not presented so it is uncertain. This study will conduct vertical drop test and identify adequacy of rockfall protection net of displacement quantity calculation factor which is delta and evaluate rockfall protection net's absorbable energy through standards of overseas performance evaluation criteria.