• Title/Summary/Keyword: Proper number of installation

Search Result 48, Processing Time 0.028 seconds

Study on Estimation of Unmanned Enforcement Equipment Installation Criteria and Proper Installation Number (무인교통단속장비 설치 판단 기준 및 설치대수 산정 연구)

  • So, Hyung-Jun;Kim, Yong-Man;Kim, Nam-Seon;Hwang, Jae-Seong;Lee, Choul-Ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.49-60
    • /
    • 2020
  • The number of traffic control equipment installed to prevent traffic accidents increases every year due to continuous installation by the National Police Agency and local governments. However, it is installed based on qualitative judgment rather than engineering analysis results. The purpose of this study was to present additional installations in the future by presenting the installation criteria considering the severity of accidents for each road type and calculating the appropriate number of installations. ARI indicators that can indicate the severity of traffic accidents were developed, and road types were classified through analysis of variance and cluster analysis, and accident information by road type was analyzed to derive ARI of clusters with high traffic accident severity. The ARI values required to determine the installation of equipment for each road type were presented, and 5,244 additional installation points were analyzed.

Analysis of Installation Status and Application of GIS for Preliminary Risk Assessment of Underground Storage Tanks in Chuncheon City (춘천시의 지하 저장 탱크의 예비적 위해성 평가를 위한 설치 현황 분석 및 지리정보시스템의 적용)

  • Kim, Joon-Hyun;Han, Young-Han;Lee, Jong-Chun;Kwon, Young-Sung;Lee, Kwang-Yeon
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.127-135
    • /
    • 2002
  • In this study, the preliminary risk assessment for the underground storage tanks(UST) in Chunchon city was implemented using the geographical information system(GIS). The estimation variables, such as the installation year, storage capacity, the distances from streams, and from groundwater pumping wells, were selected to estimate the relative risk levels. The weighting factors were given to all the estimation variables. Cumulative scores were induced by the combination of all the scores of the corresponding variables using the buffering technique and the overlay analysis in ArcView. Using the these process, the relative risk level of each UST was estimated. Some sites in this study are simplified and reduced because the number of useable data are limited or too enormous. Thus the selection of the comprehensive estimation variables and the proper weighting values are required for the future study. The methodology in this study could be served not only for the preliminary risk assessment of UST but also for the selection of the proper location of new and old UST. And, it can be used for the effective management system of UST.

  • PDF

A Study on the Spacer Installation Method for 2-Conductor Bundle Transmission Lines (2도체 송전선로의 스페이서 취부방식 연구)

  • Min, Byeong-Wook;Kim, Woo-Kyum;Choi, Han-Yeol;Park, Kee-Yong;Kim, Won-Jin;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.333-334
    • /
    • 2008
  • Overhead transmission lines are classified by the number of sub conductors per phase. Korean transmission lines use two, four, or six-conductor bundle. Bundle of conductors must have spacers or spacer dampers which keep the proper distance between sub conductors. They can prevent conductors from being vibrated or twisted due to the wind. As for the two-conductor bundle, alternating current flow generates absorption force between sub conductors which may cause a collision of sub conductors. To prevent sub conductors from being vibrated, twisted, and collided, spacer or spacer damper installation method is designed considering vibration characteristics of sub conductors. We have spacer installation method for four or six-conductor bundle lines. However, we don't have it for two-conductor bundle ones. So we have installed spacers at regular intervals in two-conductor bundle lines, and it caused rigid body oscillation of conductors due to the wind which made a flashover between conductors. This paper introduces a vibration characteristic analysis of two-conductor bundle and proposes a spacer installation method for two-conductor bundle lines.

  • PDF

Voltage Drop and Power Factor Compensation Relation of Induction Motor applied to Logistics System (물류 시스템 적용 유도전동기의 전압강하와 역률 보상 관계)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.155-159
    • /
    • 2018
  • Recently, the expansion or establishment of facilities for the logistics system is increasing. Conveyor facilities play a major role in sorting and transporting logistics. Induction motors are widely used for the operation of these conveyor systems. In the logistics system, a large number of induction motors are used. These motors have a considerable distance from the power source side and have a low power factor. The installation position for the power factor compensation of the induction motor is very important. Since the voltage drop depends on the length of the line, it is an important parameter in capacitor capacity determination for power factor compensation. The capacity of the capacitors installed to compensate the power factor of the inductive load should be designed to the extent that self-excitation does not occur. In this study, we analyze the method of compensating the proper power factor considering the voltage drop and the installation position of the induction motor in the logistics system.

Analysis and Counterplan for the Present Status of Electric Shock Accidents (감전사고로 인한 재해발생현황에 대한 분석과 대책)

  • 정타관
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.1
    • /
    • pp.49-56
    • /
    • 1992
  • This paper has analyzed various aspects of electric shock accidents on th base of the published statistical data of the Ministry of labour between 1982 and 1990. The number of electric shock accidents has suddenly been increased in 1990, because of the booming business of the building construction. It was found that many temporal electric wirings and movable electric devices in the field of construction have bee na leading cause of the electric shock accidents. In order to reduce the rate of electric shock accidents the proper authorities will have to establish the safety measures, to educate workers to prevent the accidents and to supervise more carefully.

  • PDF

An Efficient Method for Selecting DVOR Installation Site (효율적인 DVOR 설치위치 선정기법)

  • Park, Hyeong-Taek;Hwang, Byong-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3A
    • /
    • pp.319-326
    • /
    • 2008
  • All over the world more than 2,000 VORs(VHF Omni-directional Ranges) including 39 in Korea are being operated for formulating air routes. But VOR reveals some difficulties in cost and time when relocating already an installed one due to its poor performance from the interference by its geometrically surrounding obstacles. DVOR(Doppler VOR) which is more popular than CVOR(Conventional VOR) has huge antennas and make it very difficult to assume a sufficient number of proper site candidates for permanent installation. This paper develops an efficient method for predicting proper site of DVOR installation by isolating transmitter from sideband antennas and counterpoise, making the transmitter easily moveable and verifying the performance of DVOR only with a transmitter and an antenna. The method was tested with a real flight measurement for DVOR performance around Gwangju Airport in Korea.

A research on Safety and Dangerous Awareness of Environment on Walking trails (도보길환경의 안전 및 위험인식에 관한 조사연구)

  • Kim, Young-duk;Byun, Kyeonghwa
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 2018
  • The purpose of this study is to investigate safety and dangerous awareness of environment on walking trails. For this purpose, questionnaire survey are carried out by people who had experience using walking trails during 2016. It is evaluated that environments of walking trails located inside big cities are inferior than ones located in small and medium-sized cities and countryside in air pollution, bed smell, water pollution, noise, and waste. Needs about management and number installed public restroom are high for hygienic environment of walking trails. With waste treatment, users of 2.4 percentage are showed improper behavior that they left their rubbish at the place out of view but others bring their trash. Accident likelihood is highly appreciated and possibility of physical accident like slipping is showed at the highest. The reasons of accident on walking trails are responded with carelessness of walkers and improper of installation or management of safety facility at the most. For safety environment of walking trails, needs of installation of safety fences and notices of dangerous area are requested. In order to separate prevention from paths of walking trails, signposts are needed at visual clearness, maintenance, installation with proper interval and location, and correct contents. Respondents of 2.4 percentage have experiences of accident on walking trails and physical accident like slipping is occurred at the most.

A Study on the Proper Number of Banks of Parallel Operation of Transformer in Large-scale Power Plants Using the High Temperature Fuel Cell Considering the Internal Failure (내부고장을 고려한 고온형 연료전지 대규모 발전단지의 병렬운전 변압기 적정 뱅크수에 관한 연구)

  • Chong, Young-Whan;Chai, Hui-Seok;Sung, In-Je;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.26-31
    • /
    • 2014
  • High temperature fuel cell system, such as molten carbonate fuel cells(MCFC) and solid oxide fuel cells(SOFC), are capable of operating at MW rated power output. The power output change of high temperature fuel cell imposes the thermal and mechanical stresses on the fuel cell stack. To minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we should divide the power plant configuration to several banks. However, the improvement of reliability in fuel cell power plant system causes an increase of the investment cost, for example, replacement costs, labor costs, and so on. For this reason - the balance between investment and reliability improvement - many studies about the appropriate level of investment have been conducted. In this paper, we evaluate the cost for operation and installation, the benefit for electric energy and thermal energy sales, and the system reliability for several cases : these cases relate with the bank configuration.

Investigation of Natural Convective Heat Flow Characteristics of Heat Sink (히트싱크의 자연대류 열유동 특성 분석)

  • Jung, Tae Sung;Kang, Hwan Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • To ensure proper functioning of electrical and mechanical systems, cooling devices are of great importance. A heat sink is the most common cooling device used in many industries such as the semiconductor, electronic instrument, LED lighting, and automotive industries. To design an optimal heat sink, the required surface area for heat radiation should be calculated based on an accurate expectation of the heat flow rate in the target environment. In this study, the convective heat flow characteristics were numerically investigated for a vertically installed typical heat sink and a horizontally installed one in free convection using ANSYS CFX. Comparative experiments were carried out to reveal the quantitative effect of the installation direction on the cooling performance. Moreover, the result was analyzed using the dimensionless correlation with the Nusselt number and Rayleigh number and compared with well-known theories. Finally, it was observed that the cooling performance of the vertically installed heat sink is approximately 10~15% better than that of the one in natural convection.

Analysis for Traffic Accident of the Bus with Advanced Driver Assistance System (ADAS) (첨단안전장치 장착 버스의 사고사례 분석)

  • Park, Jongjin;Choi, Youngsoo;Park, Jeongman
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.3
    • /
    • pp.78-85
    • /
    • 2021
  • Recently a traffic accident of heavy duty vehicles under the mandatory installation of ADAS (Advanced Driver Assistance System) is often reported in the media. Heavy duty vehicle accidents are normally occurring a high number of passenger's injury. According to report of Insurance Institute for Highway Safety, FCW (Forward Collision Warning) and AEB (Automatic Emergency Braking) were associated with a statistically significant 12% reduction in the rate of police-reportable crashes per vehicle miles traveled, and a significant 41% reduction in the rear-end crash rate of large trucks. Also many countries around the world, including Korea, are studying the effects of ADAS installation on accident reduction. Traffic accident statistics of passenger vehicle for business purpose in TMACS (Traffic safety information Management Complex System in Korea) tends to remarkably reduce the number of deaths due to the accident (2017(211), 2018(170), 2019(139)), but the number of traffic accidents (2017(8,939), 2018(9,181), 2019(10,095)) increases. In this paper, it is introduced a traffic accident case that could lead to high injury traffic accidents by being equipped with AEB in a bus. AEB reduces accidents and damage in general but malfunction of AEB could occur severe accident. Therefore, proper education is required to use AEB system, simply instead of focusing on developing and installing AEB to prevent traffic accidents. Traffic accident of AEB equipped vehicle may arise a new dispute between a driver's fault and vehicle defect. It is highly recommended to regulate an advanced event data recorder system.