• Title/Summary/Keyword: Prevention Device

Search Result 471, Processing Time 0.032 seconds

Case Study for Efficiency of Counter-Debrisflow Structures in Baekyang Mt. (토석류 방재구조물 성능 검토 수치해석 - Case study: 부산 백양산)

  • Jeong, Seokil;Song, Chag Geun;Kim, Hong Taek;Lee, Seung Oh
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.84-89
    • /
    • 2018
  • The number of landslides has increased since the 2000s due to the increased frequency of heavy rainfall caused by abnormal weather. A variety of debris flow prevention facilities have been installed as a countermeasure against this problem. However, it is not easy to evaluate the efficiency of debris flow prevention structures except for the structures with constant volume such as the erosion dam, because the other structures are limited to be reproduced in simulation program for debris flow. Therefore, the methods by which the debris flow prevention structures were modeled were proposed, and the efficiency of four prevention structures installed in Baekyang Mt. in Busan was evaluated with UDS, which accuracy had been verified, using these methods. The initial amount of debris flow was determined based on landslide which occurred in 2014, and specifications of the complex retaining walls around the settlements were measured and applied modeling for terrain. The numerical results showed that the efficiency of debris flow prevention structures could be quantitatively presented. Among the debris flow prevention structures installed in Baekyang Mt., prevention structure of barrier type for debris flow was the most efficiency and debris flow prevention device was the lowest efficiency when the only depth of debris was evaluated. It seems that this study is meaningful to propose the methods which were used to model the debris flow prevention structures that could not be reproduced in most 2D debris flow numerical analysis programs. If precise verification of the presented methods is carried out, it will be possible to provide clear criteria for the efficiency evaluation method of disaster prevention structures.

A Study on the Fire Risk of High-voltage Cables for Electrical Vehicles (전기차용 고전압 케이블의 화재 위험성에 관한 연구)

  • Sin Dong Kang;Ye Jin Park;Si Hyun Kim;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.8-14
    • /
    • 2023
  • This study presents the characteristics of short circuits (SCs) caused by excessive currents in high-voltage cables used in electric vehicles and emphasizes the need to calculate the cross-sectional areas of these cables according to the SC current. Three direct current power supplies were connected in parallel to test the SC characteristics caused by excessive currents, and a timer and a magnetic contactor were used to deliver the conduction time and SC current. A circular infrared-radiation heater was used to test the temperature-dependent SC characteristics, a thermocouple was used to measure the temperature, and a shunt resistor was used to measure the current. As the SC current increased, the fusing time of the cable decreased. Additionally, a high-voltage cable (with an area of 16 mm2 ) used in electric vehicles fused when a current (approximately equal to 55 times the allowable current) flowed for 0.2 s (operating time of the protective device). When the SC current is 10 kA, the cable may fuse during the operating time of the protective device, thus creating a fire hazard. In electric vehicles, the size of the SC current increases in proportion to the capacity of the battery. Thus, the cross-sectional areas of the cables used should be calculated accordingly, and cable operations should be properly coordinated with the surrounding protective devices.

Postcardiotomy Mechanical Circulatory Support in Congenital Heart Diseases (소아개심술 후 시행한 순환보조장치의 임상적 고찰)

  • 권오춘;이영탁
    • Journal of Chest Surgery
    • /
    • v.33 no.5
    • /
    • pp.385-390
    • /
    • 2000
  • Background: To review the experience that used both ventricular assist device(VAD) and extracorporeal membrane oxygenation(ECMO) for children with congential heart disease requiring postcardiotomy mechanical circulatory support. Material and Method: Between March 1993 and May 1995, we applied mechanical assist device using centrifugal pump to the 16 patients who failed to be weaned from cardiopulmonary bypass(n=15) or had been in cardiogenic shock in intensive care unit(n=1). The diagnosis were all congenital heart diseases and the ages of patients ranged from 20 days to 10 years (mean age=2.5$\pm$3.5 years). Result: The methods of mechanical circulatory support were LVAD(n=13), BVAD (n=1), and ECMO(n=2). The mean assist times were 54.0$\pm$23.7 hours. Post-assist complications were in orders: bleeding, acute renal failure, ventricular failure, respiratory failure, infection, and neurologic complication. It was possible for 9 patients(56.3%) to be weaned from assist device and 5 patients(31.3%) were discharged from hospital. There was no statistical significant between hospital discharged group and undischarged group by age, body weight, cardiopulmonary bypass time, and assist time. Conclusion: The ventricular assist device is an effective modality in salvaging the patient who failed to be weaned from cardiopulmonary bypass, but multiple factors must be considered for improving the results of mechanical circulatory support ; such as patient selection, optimal time of starting the assist device, and prevention and management of the complications.

  • PDF

Effectiveness of the Microlux/DLTM Chemiluminescence Device in Screening of Potentially Malignant and Malignant Oral Lesions

  • Ibrahim, Suzan Seif;Al-Attas, Safia Ali;Darwish, Zeinab Elsayed;Amer, Hala Abbas;Hassan, Mona Hassan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6081-6086
    • /
    • 2014
  • Background: To evaluate the effectiveness of Microlux/DL with and without toluidine blue in screening of potentially malignant and malignant oral lesions. Materials and Methods: In this diagnostic clinical trial clinical examination was carried out by two teams: 1) two oral medicine consultants, and 2) two general dentists. Participants were randomly and blindly allocated for each examining team. A total of 599 tobacco users were assessed through conventional oral examination (COE); the examination was then repeated using Microlux/DL device and toluidine blue. Biopsy of suspicious lesions was performed. Also clinicians opinions regarding the two tools were obtained. Results: The sensitivity and, specificity and positive predictive value (PVP) of Microlux/DL for visualization of suspicious premalignant lesions considering COE as a gold standard (i.e screening device) were 94.3%, 99.6% and 96.2% respectively, while they were 100%, 32.4% and 17.9% when considering biopsy as a gold standard. Moreover, Microlux/DL enhanced detection of the lesion and uncovered new lesions compared to COE, whereas it did not alter the provisional clinical diagnosis, or alter the biopsy site. On the other hand, adding toluidine blue dye did not improve the effectiveness of the Microlux/DL system. Conclusions: The Microlux/DL seems to be a promising adjunctive screening device.

Effects of Parent-Child Attachment, Parental Involvement in Child-Rearing and Instruction for Children's Effective Use of Smart Devices on Young Children's Smart-Device Overuse Behavior (부모의 자녀애착, 양육 참여 및 스마트기기 사용지도가 유아의 스마트기기 과다 사용에 미치는 영향)

  • Moon, Kyung Im;Lee, Wan Jeong
    • Human Ecology Research
    • /
    • v.54 no.6
    • /
    • pp.611-620
    • /
    • 2016
  • This study examined how parent-child attachment, parental involvement in child rearing and instruction for children's effective use of a smart device reflect on young children's smart device overuse behavior. We collected questionnaires from 196 parents with children attending early childhood education institutions for the survey. Frequency analysis as well as Person correlation coefficient and regression analysis were conducted using IBM SPSS 21.0 statistics. The results showed that 91% of targeted young children were using a smart device and 78% first used them before age 5. As for time of use hours, 43.9% used their smart device from 30 minutes to 1 hour on average. In addition, parent-child attachment and father's involvement in child rearing were found to be inversely correlated to young children's smart device overuse. The result of hierarchical regression analysis on parent factors influencing young children's smart device overuse behavior indicated that mothers' contact-seeking behavior to young children, mother's involvement in learning and instruction for children's effective use of a smart device at home had beneficial effects. This study analyzed parent factors that influenced young children's smart device overindulgence. In addition, the baseline data of this study will be utilized to develop programs for the prevention and therapy to solve the smart device overindulgence as well as to establish young children's guidelines for using a smart device.

Comparison of X-ray Image Quality Between Multi-Function Device(MFD) and Weight Bearing Platforms(WBPs) (다기능 보조기구와 체중부하검사 보조기구의 X선 화질 비교)

  • Gil, Jong-Won;Lee, Kwang-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.605-611
    • /
    • 2019
  • The purpose of this study is to manufacture a multi-function device (MFD) which can be applied to various types of weight-bearing view of the lower leg, and to compare the results with the images from the existing weight-bearing platforms (WBPs), thereby suggesting a clinical utilization. The MFD was manufactured, by considering the minimum adjustable heights of the platform for weight-bearing foot/ankle, platform for hindfoot alignment view, and X-ray tube of the X-ray device. A foot/ankle phantom was used to take the images of weight-bearing lateral foot in MFD and WBPs to compare the resolutions of the X-ray images using a quick modulation transfer function (MTF) program. Between both the images taken from the MFD and WBPs, there was no statistically significant difference found in the mean cycles per pixel (C/P) and the lines per image height (LPH) of the 50%-Contrast Spatial Frequency (MTF50), and 10-90% of Maximum Energy Rise Distance (10-90%), where p>0.05. The MFD is suggested for its clinical trial as a useful positioning device that can secure the patient's safety and manifoldly perform various inspections. Also, the recommendation of the positioning device as a policy can activate dedicated manufacturers, while also improving the quality of medical services.

A Study on the Improvement of Emergency Block and Diffusion Prevention System for Hazardous Chemicals Leakage (화학물질 누출에 따른 긴급 확산 방재시스템 개선 방안 연구)

  • Lee, Deok-Jae;Yun, Jeong Hyeon;Yoo, Byung-Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.89-99
    • /
    • 2018
  • In the case of medium and small-sized businesses handling hazardous chemicals, emergency disaster prevention by workers, rather than a disaster prevention system using a safety device equipped with an automation system in case of a leak accident, is highly likely to occur. In order to solve these limitations, in this study investigated an emergency disaster prevention system that can be easily removed and adhered to the expected point of leakage according to the occurrence frequency of the leak during the chemical handling process.

Quantitative Risk Assessment based on Fault Tree Analysis for Gangform Accident (갱폼 재해의 FTA를 통한 정량적 위험성 산정에 관한 연구)

  • Ham, Young Jong;Kee, Jung Hun;Park, Jong Yil
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.40-47
    • /
    • 2020
  • Although gangform has good workability due to the integration of outer wall forms and working platforms, 22 workers were died from 21 gangform related accidents during 2012 to 2016. Quantitative risk assessment is required for evident based prevention measure selection. In this study, based on 52 accident data from 2004 to the first half of 2019, FTA is conducted for probabilities of direct causes and their contribution to accidents. Three stages are considered; gangform installation, dismantling and lifting, and using. The effectiveness of countermeasures is evaluated through minimum cut set, RAW and RRW. Complete assembly of gangform on the ground level, detailed planning, and fall prevention device are suggested as prevention measures for installation, dismantling and lifting, and using stages, respectively.

The Study for Analysis and Prevention Measure of Overhead Transmission Line Fault with Birds (조류에 의한 가공송전선로의 고장분석 및 예방대책 고찰)

  • Jung, Si-Hwan;Kang, Cheul-Won;Kim, Wan-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.96-98
    • /
    • 2006
  • Recently major power outages are increased, because of transmission line fault by birds. Therefore, after finding out the problem of the current prevention measure for the super high voltage transmission Line in Korea and analyzing the protection measure of other foreign power companies for the transmission facilities fault by birds, this paper describes an effective device for power line fault protection by birds which has no legal problem and also protects birds. The described prevention measure of power outage by birds in this paper, has a special feature that is able to be installed on the current overhead transmission facilities without a replacement or change.

  • PDF