• Title/Summary/Keyword: Preamplifier

검색결과 107건 처리시간 0.024초

난각의 음향반응에 영향을 주는 인자 (Factors Affecting Acoustic Responses of Egg Shell)

  • 조한근;최완규
    • Journal of Biosystems Engineering
    • /
    • 제22권1호
    • /
    • pp.41-48
    • /
    • 1997
  • A nondestructive quality inspection technique using acoustic impulse response method was studied to investigate the feasibility of egg shell inspection. An experimental system was built to generate impact force, to measure the response signal and to analyze the frequency spectrum. This system includes an impulse generating unit, an egg holding seat, a microphone with preamplifier, and a digital oscilloscope connected to Personal Computer by RS-232C interface. The factors such as impulse generating method, egg holding method, and sensor location were evaluated by analyzing the power spectrum density of the measured signal. The results obtained are summarized as follows : 1. From the sampled eggs, the proper conditions for detecting damaged eggs were found as followings; ceramic for the impact ball material, rubber for egg seat material, 20 degrees for an impact angle of pendulum, 10mm for the distance between egg and sensor, the sharp side for impacting part, and 180 degrees for the location of sensor. 2. Examination of the Fourier transformed analysis in beth normal and damaged eggs revealed that those factors such as the resonant frequency, a number of peak frequencies and the magnitude of power spectrum were important to detect damaged eggs.

  • PDF

실리콘 핀 포토다이오드를 이용한 전자 선량계의 설계 및 구현 (A Study on the Development of Electronic Personal Dosimeter with Silicon PIN Photodiode)

  • 이운근;권석근;김중선;손창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2285-2288
    • /
    • 2002
  • Recently, electronic personal dosimeters based upon silicon PIN photodiode or miniature GM tube were developed and have attracted a lot of attention because of the advantages of their nature such as indication of dose rate and the cumulative dose, and facilitation of record keeping. In this paper, we have developed a high-sensitivity electronic personal dosimeter with silicon PIN photodiode. The electronic personal dosimeter is constructed with silicon PIN photodiode, preamplifier, and shaping amplifier. To show the effectiveness of electronic personal dosimeter, we conducted nuclear radiation experiments using $\gamma$-ray Ba-133, Cs-137, and Co-60. The electronic personal dosimeter have a good linearity on $\gamma$-ray energy and activity.

  • PDF

SFF의 고속 10 Gbps PIN PD 광수신기 (10Gbps PIN PD Receiver of SFF Package)

  • 신명훈;윤경훈;최형규;전정은;김문일;구은정;박찬용
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2004년도 제15회 정기총회 및 동계학술발표회
    • /
    • pp.284-285
    • /
    • 2004
  • We have developed a 10 Gbps receiver consist of an InGaAs PIN PD and an embedded TIA(transimpedance preamplifier). The receiver is assembled in a small form factor (SFF) Package. It shows f-3dB of 10 GHz and the sensitivity more than -20 dBm at 10$^{-10}$ BER (bit-error-rate) for 10 Gbps optical input signal of 2$^{31}$-1 PRBS (pseudo-random-bit-sequence).

  • PDF

저잡음 뇌파 전치 증폭기의 개발 (The Development of Low-noise EEG Preamplifier)

  • 유선국;김남현;김선호;송재성;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.68-70
    • /
    • 1995
  • A low-noise pre-amplifier is developed for use in Topographic Brain Mapping system. It consists of signal generator, signal amplifier with a impedance converter, shield driver, body driver, differential amplifier, and isolation amplifier. Pre-amplifier circuit is designed with the concept of isolation and active body and shield driver. This amplifier shows the good noise behavior, high CMRR, high input impedance, low leakage current and high IMRR.

  • PDF

간단한 Analog 기억장치의 제작과 그 응용 (A Simple Fast Analog Storage Device and Its Applications)

  • 배인태;최규원;김하석
    • 대한화학회지
    • /
    • 제25권2호
    • /
    • pp.103-109
    • /
    • 1981
  • 큰 입력지향을 갖는 20개의 sample and hold가 MOSFET으로 switching되는 간편하면서도 비용이 적게드는 analog 기억장치를 제작하였다. 이것은 digital로 3KHz.까지 임의로 조절되는 shift register로 연결되어 있다. 이 장치의 유용성을 보이기 위해 square와 sine파 및 fast-scan voltammetry와 differential pulse polarography의 전류-시간 변화와 같은 전기화학적 실험을 행하였다.

  • PDF

다층 저항판 검출기용 신호 검출 전자 회로 설계 (Design of a Front-End Electronic Circuit for Signal Detection on Multi-gap Resistive Plate)

  • 이승욱;김종태;채종서
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2552-2554
    • /
    • 2001
  • This paper presents a front-end electronic circuits for signal detection on multi-gap resistive plate. The input to the circuit is the signal(voltage : -800mv, frequency : 20${\sim}$40MHZ, noise : 50mv, 1GHz) from the multi-gap resistive plate chamber and the output is the 5v pulse signal. The front-end electronic circuit consists of preamplifier, peak-detector, and comparator. Spice simulation show that the circuit has the better response time than the one of the conventional measuring instruments.

  • PDF

데이터 지연방식의 CDR을 이용한 광 송신기 설계 (Design of Optical Receiver with CDR using Delayed Data Topology)

  • 김경민;강형원;최영완
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2005년도 하계학술대회
    • /
    • pp.154-158
    • /
    • 2005
  • In this paper, we design optical receiver composed of CDR(clock and data recovery), SA(sense amp), TIA(transimpe dence amplifier), and decision circuit. The optical receiver can be classified to two main block, one is Deserializer composed of CDR and SA, another is PD receiver composed of preamplifier(샴), peak detector, etc. In this paper, we propose CDR using delayed data topology that could improve defects of existing CDR. The optical receiver that is proposed in this paper has the role of translation a 1.25 Gb/s optical signal to $10{\times}125 Mb/s$ array electric signals. This optical receiver is verified by simulator(hspice) using 0.35 um CMOS technology.

  • PDF

Design of the Low Energy Electron Detector for DITSAT-B

  • Park, Young-Wan-;Min, Kyoung-Wook
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.22-22
    • /
    • 1993
  • We developed the low energy electron detector (LEED) for KITSAT-B which was launched on September 26, 1998. The sensor head is mounted on the top of the satellite so that it can measure the precipitating electron flux along the Magnetic field line in the auroral zone at 820 km altitude. The detector system is composed of 4 parts : the electrostatic analyzer, the spira10on detector, the discriminator / Preamplifier, and the interface to the spacecraft. The analyzer limits the access to the spiraltron only to the electrons of certain energies which are determined by the electrostatic field across the two coaxial cylindrical analyzer plates. The energy spectrum of the detector in consideration is about 100 eV to 6.7 KeV, which is swept in 1.6 seconds and divided into 16 bins. It 81so is 1.6 second reset period after each swept, We will discuss the technical features of the system as well as the future observational schedule.

  • PDF

신경신호기록용 능동형 반도체미세전극을 위한 CMOS 전치증폭기의 잡음특성 설계방법 (Noise Performance Design of CMOS Preamplifier for the Active Semiconductor Neural Probe)

  • 김경환;김성준
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권5호
    • /
    • pp.477-485
    • /
    • 2000
  • 본 논문에서는 신경신호기록을 위한 반도체 미세전극용 전치증폭기의 잡음특성을 설계하기 위한 체계적인 방법을 제시한다. 세포외기록(extracellular recording)에 의하여 측정된 신경신호와 전형적인 CMOS소자의 저주파 잡음특성을 함계 고려하여 전체 신호대잡음비를 계산하였다. 2단 CMOS 차동증폭기에 대한 해석과 함께 신호대잡음비에 중요한 영향을 끼치는 요소들에 대하여 설명하였다. 출력잡음전력에 대한 해석적인식을 유도하였으며 이로부터 회로설계자가 조절할 수 있는 주파수응답과 소자 파라미터들을 결정하였다. 입력소자의 크기와 트랜스컨덕턴스의 비가 최적영역으로부터 약간 벗어날 경우에 신호대잡음비가 크게 저하됨을 보였다. 이와 함께 만족스런 잡음특성을 위한 증폭이의 설계 변수 값들도 제시하였다.

  • PDF

A scintillation detector configuration for pulse shape analysis

  • Van Chuan, Phan;Hoa, Nguyen Duc;Hai, Nguyen Xuan;Anh, Nguyen Ngoc;Dien, Nguyen Nhi;Khang, Pham Dinh
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1426-1432
    • /
    • 2018
  • This paper presents a neutron detector configuration using EJ-301 scintillation liquid, a R9420 photo-multiplier and a homemade preamplifier. The detector qualities which include the energy linearity, efficiency response and neutron/gamma discrimination are guaranteed for neutron detection in the energy range from 0 to 3000 keVee. Regarding the neutron/gamma discrimination capability, four pulse shape discrimination (PSD) methods which are the threshold crossing time (TCT), pulse gradient analysis (PGA), charge comparison (CC) and correlation pattern recognition (CPR), were evaluated and discussed; among of these, the CPR method provides the best neutron/gamma discrimination.