• 제목/요약/키워드: Power transformers

검색결과 720건 처리시간 0.027초

PSIM 모델을 이용한 변압기 모델링 및 회로상수 추출방법 (An Effective Gyrator-based Transformer Modeling using PSIM)

  • 최희수;최성진
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.207-214
    • /
    • 2016
  • Magnetic circuit is a physical modeling method that is useful in designing and analyzing power transformers, especially for a priori evaluation of leakage and magnetizing inductance before actual production. In this study, a novel modeling approach that uses PSIM magnetic elements adopting gyrator and permeance-capacitances is investigated. A formula to determine the permeance-capacitors in the core and leakage path are established, and a simulation jig is devised to link the physical model and the electrical terminal characteristics with an automated parameter determination process. The derived formula is verified by measurement results of the prototype transformer samples. Given its accuracy and simplicity, this approach is suitable for analyzing and designing LLC resonant transformers whose leakage and magnetizing inductance are very critical to circuit operation.

Analysis, Design and Implementation of an Interleaved DC/DC Converter with Series-Connected Transformers

  • Lin, Bor-Ren;Chen, Chih-Chieh
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.643-653
    • /
    • 2012
  • An interleaved DC/DC converter with series-connected transformers is presented to implement the features of zero voltage switching (ZVS), load current sharing and ripple current reduction. The proposed converter includes two half-bridge converter cells connected in series to reduce the voltage stress of the switches at one-half of the input voltage. The output sides of the two converter cells with interleaved pulse-width modulation are connected in parallel to reduce the ripple current at the output capacitor and to achieve load current sharing. Therefore, the size of the output chokes and the capacitor can be reduced. The output capacitances of the MOSFETs and the resonant inductances are resonant at the transition instant to achieve ZVS turn-on. In addition, the switching losses on the power switches are reduced. Finally, experiments on a laboratory prototype (24V/40A) are provided to demonstrate the performance of the proposed converter.

유입전력용 변압기의 수명평가 기술 (Assessing the Life of the Oil-filled Transformer)

  • 박현주;남창현;윤여찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.498-499
    • /
    • 2006
  • Oil-filled transformer technology has been around more than 100 years. The principle of operation in the same today as it has been for the previous decades. But all transformers have their life so it is important to know their useful life and the time for replacement. This paper will address this issue and provide the distribution transformer oil aging test results. Distribution transformer and laboratory specimens were externally heated to their respective maximum temperatures. Sample of oil and paper were removed at convenient intervals for testing. We believe that the results of this study will show the possibility of assessing the life of transformers.

  • PDF

국내 변전설계를 위한 전력용변압기 기준(안)에 관한 연구 (A Study on the Criteria of Power Transformers for Substation Design in Korea)

  • 김익수;윤진열;주병수;이옥배;윤유술;정주영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.132-134
    • /
    • 2005
  • This paper represents the criteria of Power Transformers for substation design in Korea. The construction of new substations and expansion of existing facilities are commonplace projects in KEPCO(Korea Electric Power Corporation). The KEPCO has had the only design criteria, which need to be adequate criteria considering the new technology and environment in Korea.

  • PDF

超音波 信號 數의 移動平均에 의한 電力用 變壓器 豫防診 (Preventive diagnosis of the power transformer by the moving average of ultrasonic signal number)

  • 권동진;곽희로;정상진;김정부
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.432-437
    • /
    • 1996
  • This paper describes a diagnostic technique of power transformers by on-line detection of ultrasonic signals. A trend of partial discharge variation in a real transformer was estimated by counting the number of ultrasonic signals until insulation paper in the point-to-plane electrode is punctured. The number of electrical signals is closely related to the ultrasonic signals generated by partial discharge. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based on the trend analysis of ultrasonic signal number caused by partial discharge. (author). 14 refs., 10 figs.

  • PDF

다계 H-브리지 모듈로 구성된 UPFC(Unified Power flow Compensator)의 실험적 동작분석 (Experimental Operation Analysis of Unified Power Flow Controller with Cascaded H-Bridge Modules)

  • 백승택;한병문;추진부;장병훈;윤종수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.422-430
    • /
    • 2005
  • This paper describes experimental analysis of UPFC, which is composed of cascaded H-bridge modules and single-phase multi-winding transformers for isolation. The operational characteristic was analyzed through experimental works with a scaled model, and simulation results with PSCAD/EMTDC. The UPFC proposed in this paper can be directly connected to the transmission line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual WFC system applicable for the transmission system.

Modified Differential Protection for Transformers in Wind Farms

  • George, Sujo P.;Ashok, S
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.78-88
    • /
    • 2018
  • The liberalization of electricity market and environmental concerns are the major driving forces for the development of Distributed Generation (DG). The mode of grid-connected wind power generation is becoming popular and has matured as a reliable DG technology. The voltage generated by the wind generator is stepped up to the higher voltage by the transformers before connecting to the grid. Operating algorithm of the differential relays for transformer protection used in the wind farms need to be modified to take care of the dynamic nature of fault current caused by the intermittent nature of the wind power. An algorithm for the differential relay is proposed in which dual slope characteristics are adjusted with varying fault level situation according to the wind generator in service as well as with the wind speed. A case study conducted for a typical wind farm shows that the proposed method avoids mal-operation of the differential relay in varying wind power conditions.

다중브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 동적 성능분석 (Dynamic Performance Analysis of Unified Power Quality Conditioner with Cascaded H-Bridges)

  • 한병문;소용철;김현우
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.94-102
    • /
    • 2006
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

유중가스 분석법과 지능형 확률모델을 이용한 유입변압기 고장진단 (Fault Diagnosis of Oil-filled Power Transformer using DGA and Intelligent Probability Model)

  • 임재윤;이대종;지평식
    • 전기학회논문지P
    • /
    • 제65권3호
    • /
    • pp.188-193
    • /
    • 2016
  • It has been proven that the dissolved gas analysis (DGA) is the most effective and convenient method to diagnose the transformers. The DGA is a simple, inexpensive, and non intrusive technique. Among the various diagnosis methods, IEC 60599 has been widely used in transformer in service. But this method cannot offer accurate diagnosis for all the faults. This paper proposes a fault diagnosis method of oil-filled power transformers using DGA and Intelligent Probability Model. To demonstrate the validity of the proposed method, experiment is performed and its results are illustrated.

최근접 벡터 제어기법을 이용한 Cascade 3상 IHCML 인버터 (Cascade 3-Phase IHCML Inverter using maximal distension vector control)

  • 송성근;박성준;남해곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.187-189
    • /
    • 2007
  • In this paper, the cascade 3-phase IHMCL inverter using two low frequency transformers is proposed. The proposed inverter is constructed by connecting a 3-phase IHCML inverter. the cascade 3-phase IHCML inverter has several advantages. One advantage is that only one input power source is required because of using transformers to isolate. Another advantage is that the switching frequency of the high power switches is almost fundamental frequency of reference and the other the switching frequency of the low power switches is higher. It can be known that cascade 3 phase IHCML inverter has the excellent efficiency and the outstanding electric quality. lastly, we tested the 5kW cascade 3-phase IHCML inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed inverter.

  • PDF