• Title/Summary/Keyword: Power quality improvement

Search Result 577, Processing Time 0.036 seconds

On-Line Type Dynamic Voltage Restorer System by Improvement of EDLC's energy utilization ratio (EDLC의 Energy이용 향상에 의한 On-Line type Dynamic Voltage Restorer System)

  • Shon, Jin-Geun;Park, Jong-Chan;Seo, Il-Dong;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1099-1101
    • /
    • 2007
  • In this paper, a study has been performed for development of dynamic voltage restorer(DVR) system using EDLC (Electric Double Layer Capacitor) to solve voltage sags which are considered the dominant disturbances affecting power quality. With the prolific use of semiconductor devices in electrical equipment, modern-day loads are becoming increasingly sensitive to the sags and the disturbances prove to be costly to industries. As a technology-driven custom power installation, the Dynamic Voltage Restorer (DVR) is recognized to be most effective equipment that can be used to counter the voltage sag problem. Hence, this paper proposes the high-performance optimal design of On-Line type DVR system which can efficiently compensate the instantaneous voltage sag and instantaneous interruption of the utility voltage source.

  • PDF

Performance analysis of shape recognition in Senzimir mill control systems (젠지미어 압연기 제어시스템에서 형상인식에 관한 성능분석)

  • Lee, M.H.;Shin, J.M.;Han, S.I.;Kim, J.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.5
    • /
    • pp.83-90
    • /
    • 2011
  • In general, 20-high Sendzimir mills(ZRM) use small diameter work rolls to provide massive rolling force. Because of small diameter of work rolls, steel strip has a complex shape mixed with quarter, edge and center waves. Especially when the shape of the strip is controlled automatically, the actuator saturation occurs. These problems affect the productivity and quality of products. In this paper, the problems in automatic shape control of ZRM were analyzed. In order to evaluate the problems for the automatic shape control in ZRM, recognition performance was analyzed by comparing the measured shape and the recognized shape. The actuator positions by the shape recognition and the manual operation were compared. From the analysis results, the necessity of the improvement of recognition performance in ZRM is suggested.

Performance Evaluation of Inter-Locking Block Using Fly Ash

  • Shin, Byung-Chuel
    • Journal of Environmental Science International
    • /
    • v.13 no.2
    • /
    • pp.143-148
    • /
    • 2004
  • In this paper, the properties of inter - locking block using fly ash are discussed in order to provide economical advantages and improve quality, and protect environment and recycle resources. Fly ash is the by-product of coal in thermal power plant. The experimental parameters are fly ash content, the amount of AE water - reducing agent and mixing proportion of cement mortar. According to the experimental results, the improvement of quality in the side of strength, absorption ratio and freeze - thaw resistance for manufacturing inter -locking block and the curtailment of cost can be achieved in case of 15% of fly ash and 0.3% of AE water- reducing agent are mixed into mortar mixture of 1 :6(C:S).

Qualitative Noise Characteristics of Rotating Polygonal Disk Applied to Digital Printer Systems (디지털 프린터에 적용되는 회전 다각형 디스크의 소음특성)

  • Jo, Jun-Hyeon;Kim, Hyeong-Chae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1425-1429
    • /
    • 2007
  • Consumer's product selection measures are being shifted from the units' operational performance to overall performance. Low noise, low vibration, and low power consumption rate, etc. which used to be additional quality indices, now become vital performance factors. Especially, noise and vibration characteristics are being considered as equivalent to/or even more critical than operational performance in certain products such as office machines and home entertainment systems, which share the same space with human being's daily life. Therefore, noise reduction and sound quality improvement technology becomes an inevitable design issue for those applications. Qualitative noise characteristics of rotating polygonal disk applied to digital printer systems are presented. Overall sound pressure level change and tonal noise variation with respect to the geometrical properties of polygonal disk, operational speed, and others are briefly discussed based on experimental results.

  • PDF

Qualitative Noise Characteristics of Rotating Polygonal Disk Applied to Digital Printer Systems (디지털 프린터에 적용되는 회전 다각형 디스크의 소음특성)

  • Jo, Jun-Hyeon;Kim, Hyeong-Chae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.606-611
    • /
    • 2008
  • Consumer's product selection measures are being shifted from the units' operational performance to overall performance. Low noise, low vibration, and low power consumption rate, etc. which used to be additional quality indices, now become vital performance factors. Especially, noise and vibration characteristics are being considered as equivalent to/or even more critical than operational performance in certain products such as office machines and home entertainment systems, which share the same space with human being's daily life. Therefore, noise reduction and sound quality improvement technology becomes an inevitable design issue for those applications. Qualitative noise characteristics of rotating polygonal disk applied to digital printer systems are presented. Overall sound pressure level change and tonal noise variation with respect to the geometrical properties of polygonal disk, operational speed, and others are briefly discussed based on experimental results.

A Study For Improvement of Due Date Rate by Supplementing Defects of MRP Using DBR (DBR을 이용한 MRP 단점 보완에 따른 납기 준수율 향상에 관한 연구)

  • 조중현;양광모;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.299-302
    • /
    • 2004
  • Today, several manufacture enterprises are endeavoring constantly to receive order winners of subsidiary company product. There are tendencies to occupy competitive advantage in high position in price competition and in quality etc. But, it is not easy to keep it even if price has been cheap recently. Also, it is hard to be competitive advantage element more, because production smoothing was made much even if there is in quality. To keep or improve present competitive power, the due date rate is becoming importance. Several techniques with MRP, MRP II appeared in the 1970s by method to improve the these due date rate. These techniques have some defects to due date. Therefore, in this paper, MRP wishes to receive the due date rate that is improved more by supplementing having these defect by DBR of TOC.

  • PDF

Reliability Evaluation for the Advanced Pressurized water Reactor 1400 (신형경수로 1400을 위한 신뢰성 평가)

  • 강영식
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.125-134
    • /
    • 2001
  • The Advanced Pressurized rater Reactor 1400(APR1400) system is advanced of the successful Korean Nuclear Power Plants(KSNP) design which meets functional needs for safety enhancement reliability improvement, and control in the human-computer monitoring system. Therefore this paper describes the scoring model in order to justify the reliability and safety in APR 1400 under uncertainty. The structure of this paper consists of the human engineering, risk safety, quality function, safety organization management factors of the qualitative factors in chapter 2, and the expectation results of the normalized scoring model in chapter 3. Finally, the proposed reliability model have provided the technical flexibility not only for functional control fields but also for accidents protection systems in APR 1400 under uncertainty.

  • PDF

The Design and Simulation of a Fuzzy Logic Sliding Mode Controller (FLSMC) and Application to an Uninterruptible Power System Control

  • Phakamach, Phongsak;Akkaraphong, Chumphol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.389-394
    • /
    • 2004
  • A Fuzzy Logic Sliding Mode Control or FLSMC for the uninterruptible power system (UPS) is presented, which is tracking a sinusoidal ac voltage with specified frequency and amplitude. The FLSMC algorithm combines feedforward strategy with the Variable Structure Control (VSC) or Sliding Mode Control (SMC) and fuzzy logic control. The control function is derived to guarantee the existence of a sliding mode. FLSMC has an advantage that the stability of FLSMC can be proved easily in terms of VSC. Furthermore, the rules of the proposed FLSMC are independent of the number of system state variables because the input of the suggested controller is fuzzy quantity sliding surface value. Hence the rules of the proposed FLSMC can be reduced. The simulation results illustrate that the purposed approach gives a significant improvement on the tracking performances. It has the small overshoot in the transient and the smaller chattering in the steady state than the conventional VSC. Moreover, its can achieve the requirements of robustness and can supply a high-quality voltage power source in the presence of plant parameter variations, external load disturbances and nonlinear dynamic interactions.

  • PDF

Diagnosis of a trouble existence and development of prediction method for electrical equipment inside a building (건축물 내 전기설비 이상 유무 진단 및 예측기법 개발)

  • Kim, Young-Dal;Kim, Hyo-Jin;Kim, Dae-Sik;Kim, Jae-Hoon;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.31-33
    • /
    • 2005
  • The accelerating of industrial development causes electricity demand to increase. By that power equipments need high power, multi function and intelligence. Also consumers demand for guarantee power supplying of good quality and reasonable operating equipment. Also they require for reliance and stabilization of power facility. Therefore preventive maintenance of electric installation must be developed and improvement of domestic technical level is needed in the maintenance management of equipment. The diagnosis of trouble existence is technique that compares steady state with unusual condition, whereas the prediction technique makes a diagnosis of remaining equipments life. It is difficult for us to diagnose trouble existence of electric installation and to develop prediction method in building because of a wide scope for electric installation in building. And in this paper we will investigate diagnosis and prediction method for only switch part of electric installation in building.

  • PDF

Optimal Division Model Configuration Plan According to 6 Divisions 3 Ties in Korea Distribution System (국내 배전계통의 6분할 3연계 최적분할 모델 구성방안)

  • Lee, Dae-Dong;Son, Sung-Hwan;Ha, Bok-Nam;Hyun, Dong-Seok;Kim, Young-Dal
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.428-433
    • /
    • 2010
  • According as economy grows, demand for power increases and satisfaction of customer about electricity quality is rising. There is in trend that investment expense by continuously increased supply of electric power equipment is on the increase continuously, but management efficiency improvement through curtailment of supply of electric power equipment investment expense through efficient operation is required rather than to increase investment. In this study, reconsidered about 6 divisions 3 ties that is distribution line basis configuration of Daejeon Geumsan area and analyzed division and tie present condition of truthful distribution System. Examined problem analyzing average division number, tie number and tie switch number, searched about most suitable division that consider load. Hereafter, I wish to take advantage of analysis result in most suitable division and tie of truthful distribution system for power failure section reduction and investment expense curtailment.