• Title/Summary/Keyword: Power limit

Search Result 1,442, Processing Time 0.022 seconds

The Study on the Current Limiting Characteristics of YBCO Coated Conductor with Different kinds of Stabilization Layer Applied to SFCL Using Iron Core and Coil (철심과 권선을 이용한 전류제한기에 적용시킨 안정화층이 다른 YBCO Coated Conductor의 전류제한 특성에 관한 연구)

  • Lee, Dong-Heok;Du, Ho-Ik;Kim, Yong-Jin;Han, Byoung-Sung;Yim, Seong-Woo;Han, Sang-Chul;Lee, Jeong-Phil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.788-792
    • /
    • 2010
  • The yttrium-barium-copper-oxide (YBCO) coated conductor, which supplement the fault of the existing superconducting current-limit materials YBCO thin film, bismuth-strontium-calcium-copper-oxide(BSCCO) wire and bulk, has been improved its mechanical weakness and has high index; hence, after quench YBCO coated conductor could limit the fault current effectively because of fast resistance occurrence speed. Furthermore, it has wide applicable area as an current limit material because it shows different resistance occurrence tendency by the thickness and kind of stabilization material sputtered on the superconducting layer. Therefore, many researchers are carrying out the study of application of YBCO coated conductor to superconducting fault current limiter (SFCL) for making high quality current limit element, based on resistance type. On the other hand, the study for other type except resistance type has been rarely conducted for the application of YBCO coated conductor to SFCL as an current limit element. Consequently, in this study, YBCO coated conductor with different stabilization layer Cu and Stainless steel, is applied to SFCL using iron core and coil, and examine the many index points as an current limit element, such as current limit characteristic, the tendency of resistance occurrence, response time, the temperature trend for stability.

Evaluation of limit load analysis for pressure vessels - Part I: Linear and nonlinear methods

  • Chen, Xiaohui;Gao, Bingjun;Wang, Xingang
    • Steel and Composite Structures
    • /
    • v.22 no.6
    • /
    • pp.1391-1415
    • /
    • 2016
  • Limit load of pressure bearing structures was reviewed in this article. By means of the finite element analysis, limit load of pressurized cylinder with nozzle was taken as an example. Stress classification method and Elastic-plastic finite element analysis combining with limit load determination methods were used to determine limit load of cylinder with nozzle. Comparison of limit load determined by different methods, the results indicated that limit load determined by linearization method was the smallest. Limit load determined by twice elastic slope criterion was the nearest than experimental results. Elastic-plastic finite element analysis had comparably computational precision, but required time consuming. And then the requirements of computer processing and storage capacity by power system became higher and higher. Most of criteria for limit load estimation included any human factors based on a certain substantive characteristics of experimental results. The reasonable criterion should be objective and operational.

Optimization of DC Operating Voltage for GDT-Adopted SPD (가스방전관(GDT)을 적용한 서지보호장치 회로의 DC 동작전압 최적조건 고찰)

  • Choi, Jong-Min;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.92-98
    • /
    • 2012
  • It is made compulsory to install SPD for the purpose of protecting electric and electronic devices when an abnormal voltage such as lightning occurs to power line using power frequency of 60Hz. Recently, the high speed communication technology utilizing power line is receiving attention again as a communication technology for smart grid. The SPD influences the performances of power line communication when using SPD and power line communication system together. In order to improve the performance of power line communication, a proposed scheme for series connection of gas discharge tube to ZnO varistor was presented. This paper measured the impacts of series connection of GDT to SPD using ZnO varistor on the limit voltage of Class III SPD. This paper also presented the DC operating voltage of GDT which satisfies the limit voltage of power line communication system and SPD simultaneously.

Power Quality Early Warning Based on Anomaly Detection

  • Gu, Wei;Bai, Jingjing;Yuan, Xiaodong;Zhang, Shuai;Wang, Yuankai
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1171-1181
    • /
    • 2014
  • Different power quality (PQ) disturbance sources can have major impacts on the power supply grid. This study proposes, for the first time, an early warning approach to identifying PQ problems and providing early warning prompts based on the monitored data of PQ disturbance sources. To establish a steady-state power quality early warning index system, the characteristics of PQ disturbance sources are analyzed and summed up. The higher order statistics anomaly detection (HOSAD) algorithm, based on skewness and kurtosis, and hierarchical power quality early warning flow, were then used to mine limit-exceeding and abnormal data and analyze their severity. Cases studies show that the proposed approach is effective and feasible, and that it is possible to provide timely power quality early warnings for limit-exceeding and abnormal data.

Remote On-line Determination of the Load Rate Limit of Generation in AGC (AGC 운용에 있어서의 원격 On-line 최대 증감발율 취득 기법)

  • Kwon, Soon-Man;Jeon, Dong-Hoon;Moon, Won-Yong;Kim, Suk-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.119-121
    • /
    • 2000
  • The possibility of a remote on-line determination of the maximum load rates that are basically set at generation plants is investigated in automatic generation control (AGC) system. Energy management system (EMS) generates a test input to a remote power plant to get the samples of the generator output. Then from the samples it can be attempted to determine an approximate value of the load rate limit set by the operator. It is shown in computer simulation that in actual power plants the limit can be approximately determined from the input-output characteristics of the plants for a unit-step input.

  • PDF

A Study on Permissible Operation Limit of Distributed Generation System in Distribution System (배전계통에서 분산전원 운전가능 범위에 대한 연구)

  • Jung, Won-Jae;Kim, Tae-Eung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.19-21
    • /
    • 2001
  • Nowadays, small scale DGS(Distributed Generation System), as a wind power generation or photovoltaic generation, becomes to be introduced into the power distribution system. But in that case it is difficult to properly maintain the terminal voltage of low voltage customers by using only LDC(Line Drop Compensator). So, it is necessary to determine the permissible operation limit of the introduced DGS for proper voltage in distribution system. In this paper clarifies the relationship between LDC voltage regulation principle and real, reactive power of DGS, and examines the permissible operation limit of the introduced DGS in distribution system which the voltage is controlled by LDC.

  • PDF

On-line Tests of on the Yang-Yang Pumped Storage Plant for the Reactive Power Limits and the OEL Dynamics (양양양수 온라인 무효전력 운전범위 시험과 과여자제한기(OEL) 동특성 시험)

  • Kim, Dong-Joon;Moon, Young-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1343-1350
    • /
    • 2007
  • This paper describes the tests on the reactive power output limit and the Over-Excitation Limiter (OEL) dynamics of a generation unit. The suggested test methods on reactive limit can identify the allowable maximum/minimum reactive power at 100% rated MW in the steady-state unit operation condition. The on-line OEL test method can identify the time characteristics of OEL with the generation output at 50% of the rated MW. These methods are validated by applying to four Yang-Yang pumped storage units with 282 rated MVA each.

Dynamic Stability Analysis of A Vehicle in Limit Driving for Crash Avoidance (충돌회피를 위한 극한 운전시 자동차의 동적안정성 해석)

  • Kim, S.P.;Baek, W.K.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.106-123
    • /
    • 1997
  • In this study, vehicle directional stability is investigated for limit driving for crash avoidance maneuver using a full vehicle dynamic model. The model was analytically validated using typical step steering and lane change simulation. Limit driving condition for the vehicle model was quoted from research results of references. It was demonstrated that instable vehicle motion was caused by not only road conditions but also driving conditions. Also, the simulation showed that braking combined with steering caused very hazardous situation in crash avoidance maneuver. Finally, phase plane plot approach was used to evaluate the dynamic instability.

  • PDF

A Review of Plugging Limit for Steam Generator Tubes in Nuclear Power Plants (원전 증기발생기 전열관 관막음 한계 고찰)

  • Kang, Yong Seok;Lee, Kuk Hee
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.2
    • /
    • pp.10-17
    • /
    • 2020
  • Securing the integrity of steam generator tubes is an essential requirement for safe operation of nuclear power plants. Therefore, tubes that do not satisfy integrity requirements are no longer usable and must be repaired according to the related requirements. In general, the repair criterion is that the damage depth is more than 40% of the tube wall thickness. However, the plugging limit can be changed and be applied, provided a technical proof is given that integrity can be secured against specific degradation at a specific plants and that approval can be obtained from a regulatory agency. A typical example is alternative repair criteria for defects within the tube sheet or tube support plates. In this paper, a background of establishing the plugging limit for steam generator tubes and changes in maintenance criteria are reviewed as examples.

Reactive Reserve based Contingency Constrained Optimal Power Flow to Enhance Interface Flow Limits in Terms of voltage Stability

  • Hwachang Song;Lee, Byongjun
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.27-32
    • /
    • 2001
  • This paper presents a concept of reactive reserve based contingency constrained optimal power flow (RCCOPF). RCCOPF for enhancement of interface flow limit is composed of two modules, which are the modified continuation power flow (MCPF) and reactive optimal power flow (ROPF). In RCCOPF, two modules are repeatedly performed to increase interface flow margins of selected contingent states until satisfying the required enhancement of interface flow limit. In numerical simulation, a simple example with New England 39-bus test system is shown.

  • PDF