• Title/Summary/Keyword: Power equipment

Search Result 4,021, Processing Time 0.035 seconds

Analysis on the Harmonics Characteristics Due to Increase & Decrease of Nonlinear Load (비선형 부하의 증감에 따른 고조파 특성 분석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.3
    • /
    • pp.100-106
    • /
    • 2003
  • The increasing application of power electronic equipment in industrial field has led to a growing concern for harmonic distortion and the resulting impacts on system equipment and operations. Harmonic currents are generated by the operation of nonlinear loads and equipment on the power system. These are more increased by unbalance voltage of electrical distribution power systems. This paper describes harmonics characteristics generated by varying of nonlinear load at the PCC under the voltage unbalance.

A Technical Trend on On-Line Condition Monitoring and Diagnostics of Power Equipments (배전설비의 온라인 모니터링과 진단 기술 동향)

  • Lim, Wan-Soo;Lee, Tae-Woo;Yeo, Woon-Cheol;Lee, Sung-Gil;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1974-1975
    • /
    • 2007
  • Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system. The paper presents the results of wireless temperature monitoring of switchgear at a power plant over a two-year period.

  • PDF

Effects of Combined Training with Respiratory Equipment on Lung Function, Balance, and Life Satisfaction of Elderly People in Community

  • Kim, Eun-Ja
    • International journal of advanced smart convergence
    • /
    • v.11 no.4
    • /
    • pp.216-226
    • /
    • 2022
  • In this study, we selected and trained 9 people in the diaphragm training group and 9 people in the power-breath training group among elderly people aged 65 or older living in the community, and investigated the effect of combined training using respiratory equipment on lung function, balance, and life satisfaction. We conducted the elderly to do combined exercises, twice a week for a total of 6 weeks, that include the breathing training by diaphragm, the breathing training using Power-breath equipment, and the training using a theraband. We evaluated the changes in the lung function, the balance, and the life satisfaction before and after the intervention for our study subjects.As a result of our measurement, lung function, balance, and life satisfaction showed significant changes in the experimental group that performed the combined training using Power-breath equipment. As a result of the study, we confirmed that the elderly in the community had a positive effect on the life satisfaction by improving lung function and balance ability after conducting a combined training using respiratory equipment.

The investigation of field condition on flood protection of substation and underground power equipment (pad-mounted transformers & switches) (수변전실 및 지중 배전기기의 침수 방지 관련 현장 조사 분석)

  • Kim, Gi-Hyun;Choi, Myeong-Il;Bae, Suk-Myong;Lee, Jae-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.327-331
    • /
    • 2007
  • Inundation of substation and underground power equipment(pad-mounted transformers & switches) breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation of substation and underground power equipment, it occurs a great economic loss owing to recovery time and events of electric shock occur by inundation electrical facility. So we search the damage situation and installation situations. Therefore we propose the necessity of protection of flood at low-lying downtown and low-tying shore. This paper will be used to present a reform proposal of electrical related law about flood protection of existing power equipment.

  • PDF

Geometric structure and electronic behavior of Rh decorating effect on zigzag CNTs (n=7-12): A DFT study

  • Cui, Hao;Zhang, Xiaoxing;Zhou, Yongjian;Zhang, Jun
    • Carbon letters
    • /
    • v.26
    • /
    • pp.61-65
    • /
    • 2018
  • Comprehensive calculations of the Rh decoration effect on zigzag CNTs with n ranging from 7 to 12 were conducted in this work to understand the effect of Rh doping on geometric structures and electronic behaviors upon metallic and semiconducting CNTs. The obtained results indicated that Rh dopant not only contributes to the deformation of C-C bonds on the sidewall of CNTs, but also transforms the electron distribution of related complexes, thereby leading to a remarkable increase of the conductivity of pure CNTs given the emerged novel state within the energy gap for metallic CNTs and the narrowed energy gap for semiconducting CNTs. Our calculations will be meaningful for exploiting novel CNT-based materials with better sensitivity to electrons and higher electrical conductivity compared with pure CNTs.

A Development of Measuring Instrument of Portable Partial Discharge for Diagnosis of GIS Installation and Application (GIS 설비 진단을 위한 포터블 부분방전 측정장치 개발 및 응용)

  • Kim, Jong-Seo;Kim, Jin-Tea;Shin, Heung-Sik;Lee, Heung-Jea
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.231-234
    • /
    • 2009
  • Recently, to the development of a highly information-oriented society to a large increase in dependence on power, Accordingly, it is need that active development and spread of preservation technology on accident prevention in operation electrical equipment. However, to lack of the use on maintenance technology of power equipment and to increase of power usage is growing deterioration of power equipment, this is a cause on casualties, property damage and the occurrence of disasters is a growing. GIS equipments which are operated from domestic except the equipment which manages from the big business are depend on a most visual inspection, and do inspection method or measuring instrument etc. a condition which is not supplied widely. Currently, many to measure instrument used in domestic is very expensive or foreign, it will be able to substitute this, the development necessity of the diagnosis technique and the measuring instrument is demanded.

On the Controlled-spin Intensity Method For the Tangentially-fired Furnaces

  • Shifa Ding;Jianghong Kuang;Pingyuan Liu;Chaosong Chen;Xingsheng Hu;Handing Cao;Jinyuan Xu
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.213-216
    • /
    • 2003
  • This paper put forward the controlled spin intensity method for the tangentially-fired furnaces to solve the problems existed in the counter-tangential operation. The numerical simulation was used in this paper to discuss some basic principles.

  • PDF

A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant (수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구)

  • Byun, Doo-Gyoon;Chang, Moon-Soung;Kim, Ju-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

Equipment Qualification of a Safety-related Large Induction Motor for Nuclear Power Plants (원자력발전소 안전등급 대형유도전동기의 기기검증)

  • Ko, W.S.;Kim, J.;Hur, I.G.;Choi, B.W.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.498-503
    • /
    • 2000
  • A safety-related equipment for use in Nuclear Power Plant should be needed an Equipment Qualification. This paper presents the approach, methods, philosophies, and procedures for qualifying the large squirrel-cage induction electric pump motors for use in ULCHIN 5&6 Nuclear Power Plants. In this paper, the method of qualification is a combination of type test and analysis method, which is composed of Radiation exposure test, Seismic simulation test, Thermal aging analysis for non-metallic materials and Seismic analysis. It is found that the motor performs its safety function with no failure mechanism under postulated service conditions.

  • PDF

Computationally Efficient 2-D DOA Estimation Using Two Parallel Uniform Linear Arrays

  • Cao, Hailin;Yang, Lisheng;Tan, Xiaoheng;Yang, Shizhong
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.806-808
    • /
    • 2009
  • A new computationally efficient algorithm-based propagator method for two-dimensional (2-D) direction-of-arrival (DOA) estimation is proposed, which uses two parallel uniform linear arrays. The algorithm takes advantage of the special structure of the array which enables 2-D DOA estimation without pair matching. Simulation results show that the proposed algorithm achieves very accurate estimation at a computational cost 4 dB lower than that of standard methods.