• Title/Summary/Keyword: Power and phase detecting

Search Result 99, Processing Time 0.022 seconds

A Study of improving PWM converter performance using the compensation algorithm of phase detector deviation (위상 검출기 편차 보상 알고림즘을 이용한 PWM컨버터 성능개선)

  • 이근호;윤길문;정연우;김한종;이제필
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.315-318
    • /
    • 1999
  • In the 3-phase PWM converter, accurate detection of the supplied voltage phase is very important. But a detecting circuit cannot avoid generating the deviation of phase detector so that we need to compensate it. In this paper, an accurate and simple compensating method of deviation of phase detector is proposed.

  • PDF

Design of power and phase feedback control system for ion cyclotron resonance heating in the Experimental Advanced Superconducting Tokamak

  • L.N. Liu;W.M. Zheng;X.J. Zhang;H. Yang;S. Yuan;Y.Z. Mao;W. Zhang;G.H. Zhu;L. Wang;C.M. Qin;Y.P. Zhao;Y. Cheng;K. Zhang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.216-221
    • /
    • 2024
  • Ion cyclotron range of frequency (ICRF) heating system is an important auxiliary heating method in the experimental Advanced Superconducting Tokamak (EAST). In EAST, several megawatts of power are transmitted with coaxial transmission lines and coupled to the plasma. For the long pulse and high power operation of the ICRF waves heating system, it is very important to effectively control the power and initial phase of the ICRF signals. In this paper, a power and phase feedback control system is described based on field programmable gate array (FPGA) devices, which can realize complicated algorithms with the advantages of fast running and high reliability. The transmitted power and antenna phase are measured by a power and phase detector and digitized. The power and phase feedback control algorithms is designed to achieve the target power and antenna phase. The power feedback control system was tested on a dummy load and during plasma experiments. Test results confirm that the feedback control system can precisely control ICRF power and antenna phase and is robust during plasma variations.

Three-Phase PWM-Switched Autotransformer Voltage-Sag Compensator Based on Phase Angle Analysis

  • Mansor, Muhamad;Rahim, Nasrudin Abd.
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.897-903
    • /
    • 2011
  • Many voltage sag compensators have been introduced, including the traditional dynamic voltage restorer (DVR), which requires an energy storage device but is inadequate for compensating deep and long-duration voltage sags. The AC-AC sag compensators introduced next do not require a storage device and they are capable of compensating voltage sags. This type of compensator needs an AC-AC converter to regulate the output voltage. Presented in this paper is a three-phase PWM-switched autotransformer voltage sag compensator based on an AC-AC converter that uses a proposed detection technique and PWM voltage control as a controller. Its effectiveness and capability in instantly detecting and compensating voltage sags were verified via MATLAB/Simulink simulations and further investigated through a laboratory prototype developed with a TMS320F2812 DSP as the main controller.

Wireless Sensor for Diagnostics of Electric Equipments (전력 설비 감시를 위한 무선 센서)

  • Choi, Yong-Sung;Kim, Hyung-Gon;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.98-102
    • /
    • 2008
  • Methods and analysis of a simple wireless sensor concept for detecting and locating faults as well as for load monitoring are presented. The concept is based on distributed wireless sensors that are attached to the incoming and outgoing power lines of secondary substations. A sensor measures only phase current characteristics of the wire it is attached to, is not synchronized to other sensors and does not need configuration of triggering levels. The main novelty of the concept is in detecting and locating faults by combining power distribution network characteristics on system level with low power sampling methods for individual sensors. This concept enables the sensor design to be simple, energy efficient and thus applicable in new installations and for retrofit purposes in both overhead and underground electrical distribution systems.

  • PDF

The position detecting method in SRM using pattern of phase current (SRM의 상전류 패턴을 이용한 회전자 위치 검출기법)

  • Kim, Tae-Hyoung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.558-561
    • /
    • 2005
  • This paper describes a novel method of detecting excitation position in switched reluctance motor(SRM) drive. Some strategies of position sensorless control methods for the motor include the measurement of phase current and applied pulse voltage in an unexcited phase is suggested. The principle of the estimation of a rotor position is based on the detection of inductance by pulse currents. This sensorless method is very simple to detect excitation position estimation and gives efficient control of drive system. Suggested method is verified by some simulations.

  • PDF

Single Current Sensor Technique considering a Snubber Current and a Modified SVPWM Inverter for AC Motor Drives (스누버 전류를 고려한 개선된 SVPWM 인버터를 이용한 상전류센서없는 전동기 구동)

  • 주형길;신휘범;안희욱;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.399-402
    • /
    • 1999
  • The single sensor technique reconstructing phase currents from the dc-link current without phase current sensors in proposed. When the duration of active vector is too short for the snubber current to reduce, the dc-link current including the snubber current gives large detection error. The solution is presented by analyzing the snubber current and modifying the switching sequences. This scheme is simple, requires only one sampling a period and has good results for detecting the phase currents.

  • PDF

A Design and Experiment of Pressure and Shape Adaptive Mechanism for Detection of Defects in Wind Power Blade (풍력 발전용 블레이드 접합부의 결함 검출을 위한 일정가압 메커니즘 설계 및 실험)

  • Lim, Sun;Lim, Seung Hwan;Jeong, Ye Chan;Chi, Su Chung;Nam, Mun Ho
    • Journal of Applied Reliability
    • /
    • v.17 no.3
    • /
    • pp.224-235
    • /
    • 2017
  • Purpose: Reliability is the most important factor to detect defects as wind turbines are deployed in large blades. The methods of detecting defects are various, such as non-destructive inspection and thermal imaging inspection. We propose the phased array ultrasonic testing method of non-destructive testing. Methods: We propose the active pressure mechanism for wind power blade. The phase array ultrasonic inspection method is used for fault detection inner blade surface. Controlled pressure of mechanism with respect to z-axis is important for guarantee the result of phase array ultrasonic inspection. The model based control and proposed mechanism are utilized for overall system stability and effectiveness of system. Result: The result of proposed pressure mechanism B is more stable than A. Convergence speed is also faster than A. Conclusion: We confirmed the performance of the proposed constant pressure mechanism through experiments. Non-destructive testing was applied to the specimen to confirm the reliability of detecting defects.

Performance Analysis of a Three-Phase Parallel Active Power Filter which Compensates PCC Voltage and the Unbalanced Loads

  • Lee, Woo-Cheol;Lee, Taeck-Kie;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.9-18
    • /
    • 2001
  • The performance analysis of a three-phase parallel active power filter that compensates PCC voltage and the unbalanced loads is presented in this paper. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. Firstly, it operates as a conventional active filter with reactive power compensation when PCC voltage is within the 15% voltage drop range. Secondly, it operates as a voltage compensator when PCC voltage is not within the 15% voltage drop range. And both APF and voltage compensator compensate asymmetries caused by nonlinear loads. Finally, two methods of detecting the negative sequence are reviewed, and the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rate at 10KVA.

  • PDF

Development of a Low-cost Lighting System for Line-acan Camera (라인 스캔 카메라를 위한 저가형 시 균일 조명장치 구현)

  • Kim, Hong-Gap;Kim, Hyeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.5
    • /
    • pp.235-240
    • /
    • 2000
  • A low cost lighting system for line-scan cameras has been developed with 3-phase power. When exposure time of line-scan camera is shorter than fluctuation period of illumination, the average gray value of each acquired 1-D image varies. Detecting defects on the objects's surface under such illuminating environment is very difficult. The proposed lighting system is composed of low-cost fluorescent lights based on 3-phase power. The specially designed lighting pack and the properly selected lighting position enable to get the rippleless lighting. The principle of the proposed lighting system has been explained analytically. The lighting system has been tested for fabric inspection with line-scan camera and it's efficacy has been proved.

  • PDF

Characteristics of Ultra High Frequency Partial Discharge Signals from Metallic Particle Defected Oil-paper Insulation in Transformer (변압기 절연지 표면 금속 이물질 방전에 의한 극초단파 신호특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.879-883
    • /
    • 2009
  • This paper was provided to help in detecting defects in power transformer. For this purpose, a partial discharge cell was designed and manufactured as a discharge source to simulate particle defected paper-oil insulation in power transformer. Experimental set-up for measuring PD signals was described. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and pattern of PRPD(Phase Resolved Partial Discharge) of partial discharge signals were examined and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the substation faults.